Omron 08 Cat 1-302 5/10/07 15:39 Page 78 PCB Power Relay G2RGText TPCB Power Relay G5Q-EUext Compact, High Isolation Relay Dimensions ROHS compliant. 13.5 max. Compact single pole relay with high isolation (12.8)* 29 max. 5 Six, 1.3-dia. holes (28.6)* between coil and contacts. (2.7) 13 4 Up to 10 A 250 VAC switching on the NO 25.5 max. 7.5 (24.7)* contacts. 8 6 5 Ensures a withstand impulse voltage of (2.1) 20 (2.1) 8,000 V between the coil and contacts. 4 0.5 1 0.3 0.15 Low coil power consumption *Figures in parentheses indicate average values. (SPST-NO: 200 mW, SPDT: 400 mW. UL class F coil insulation. Precautions UL, CSA and EN approvals. Ideal for appliance and HVAC controls. Correct Use Tracking resistance: CTI > 250. Differences with the G2R The G2RG-2A4 has the same terminal arrangement as the G2R-2A4 but the switch capacity and electrical endurance are different. Confirm that correct operation is possible in the actual operating conditions before using in applications. Ordering Information To Order: Select the part number and add the desired coil voltage rating (e.g. G5Q-14-EU-DC12) Classification Enclosure rating Part number Single contact, Class F coil SPST-NO Vented G5Q-1A-EU Sealed G5Q-1A4-EU SPDT Vented G5Q-1-EU Sealed G5Q-14-EU Note: When ordering, add the rated coil voltage to the model number. Examples : G5Q 12VDC Rated Coil Voltage Model Number Legend G5Q- -EU VDC 1 2 3 1. Number of Poles 3. Rated Coil Voltage 1: 1 pole 5, 12, 24VDC 2. Contact Form None: SPDT A: SPST-NO Specifications Coil Ratings Rated voltage (V) Rated Coil Pick-up Drop-out Maximum Power current resistance voltage Voltage voltage consumption (mA) () (mW) SPDT DC5 80 63 75% of max. 5% of max. 190% at 23C 400 DC12 33.3 360 DC24 16.7 1440 SPST-NO DC5 40 125 200 DC12 16.7 720 ALL DIMENSIONS SHOWN ARE IN MILLIMETRES. DC24 8.3 2880 To convert millimetres into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Note: Rated current and coil resistance are measured at 23C with a tolerance of 10%. CAT. No. K142-E2-02A-X 78 79 Power RelaysOmron 08 Cat 1-302 5/10/07 15:39 Page 80 PCB Power Relay G5Q-EUText TPCB Power Relay G5Q-EUext Contact Ratings UL508 (File No. E41515) CSA C22.2 No. 14 (File No. LR31928) Load SPDT SPST-NO Rated load (resistive) 10A at 250 VAC (NO) 10A at 250 VAC Model Coil ratings Contact ratings 3A at 250 VAC (NO) 3A at 250 VAC 3A at 125 VAC (NO) 3A at 125 VAC NO contacts NO contacts 5A at 30 VDC (NO) 5A at 30 VDC G5Q-EU 5-48 VDC 10 A, 250 VAC resistive 3 A, 250 VAC resistive 3A at 250 VAC (NC) 10 A, 30 VDC resistive 3 A, 30 VDC resistive 3A at 125 VAC (NC) 4 A, 120 VAC resistive, 4 LRA, 2 FLA, 120 VAC definite 3A at 30 VDC (NC) 100,000 ops. purpose, 100,000 operations. Contact material AgNi 4 FLA, 4 LRA 120 VAC, definite purpose, 100,000 operations. Rated carry current AC 10 A DC 5A (NO)/ AC 3A DC 3A (NC) Note: Ratings for both NO contacts and NC contacts are given at 105C (221F). Max. switching voltage 277 VAC, 30 VDC Max. switching current AC: 10 A (NO)/3 A (NC) EN 61810-1 (VDE Reg. no 125314) DC: 5 A (NO)/3 A (NC) Max. switching capacity 2500 VA, 150 W (NO) Model Coil ratings Contact ratings 750 VA, 90 W (NC) G5Q-EU 5,12, 24 VDC 10 A, 250 VAC -6 Min. permissible load 10 mA at 5 VDC (P level: 60 = 0.1 x 10 operation) 5 A, 30 VDC (NO) Note: P level: 60 = 0.1 x 10-6/operation 3 A, 250 VDC (NC) Characteristics Engineering Data Contact resistance (see note 2) 100 m max. Operate time 10 ms max. Release time 5 ms max. Insulation resistance (see note 3) 1,000 M min. Dielectric strength 4,000 VAC, 50/60 Hz for 1 min between coil and contacts 1,000 VAC, 50/60 Hz for 1 min between contacts of same polarity Impulse withstand voltage 8 kV (1.2 x 50 ms) between coil and contacts Insulation Creepage (Typ) 6.7 mm Distance Clearance (Typ) 5.8 mm Tracking Resistance (CTI) 250 V Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours Malfunction: 10 to 55 Hz, 1.5-mm double amplitude for 5 minutes 2 Shock resistance Destruction: 1,000 m/s (approx. 100G) 2 Malfunction: 100 m/s (approximately 10G) Life expectancy (see note 4) Mechanical 10,000,000 operations (18,000 operations per hour) Electrical 200,000 operations: 3 A (NO)/3 A (NC) at 125 VAC resistive load 100,000 operations: 3 A (NO)/3 A (NC) at 250 VAC 5 A (NO)/3 A (NC) at 30 VDC resistive load 25,000 operations: 10A (NO) at 250 VAC (900 operations per hour: 1 sec ON/3 sec OFF) Switching frequency: 1,800 operations per hour: 1 sec ON/1 SEC OFF Ambient temperature Operating: -40C to 85C (with no icing) Ambient humidity Operating: 5% to 85% Note: 1. The data shown above are initial value. 2. The contact resistance is possible with 1 A applied at 5 VDC using a fall-of-potential method. 3. The insulation resistance is possible between coil and contacts and between contacts of the same polarity at 500 VDC. 4. The electrical life data items shown are possible at 23C. 80 81 Power Relays