- - G5RL-U/-K PCB Power Relay 16 A High Switching Current, General-purpose Latching Relay Creepage distance 8 mm between coil and contacts. 10 kV Impulse withstand voltage. Ambient Operating Temperature 85C Suitable for TV-8 rating. (SPST-NO (1a)) RoHS Compliant Model Number Legend Application Examples Housing equipments G5RL- - Building Automation 12 3 4 UPS, FA equipment G 1. Relay Function 3. Contact Form 5 Electric power meter U : Single-winding latching None: SPDT (1c) R L K : Double-winding latching A : SPST-NO (1a) U 2. Number of poles 4. Classification / 1: 1-Pole E : High-capacity K Ordering Information Single-winding latching Double-winding latching Minimum Classification Terminal Shape Contact form Enclosure rating Model Rated coil voltage Model Rated coil voltage packing unit 3 VDC SPST-NO G5RL-U1A-E G5RL-K1A-E 5 VDC 5 VDC (1a) High-capacity PCB terminals Flux protection 6 VDC 12 VDC 100 pcs/tray 12 VDC 24 VDC SPDT (1c) G5RL-U1-E G5RL-K1-E 24 VDC Note. When ordering, add the rated coil voltage to the model number. Example: G5RL-U1A-E DC5 Rated coil voltage However, the notation of the coil voltage on the product case as well as on the packing will be marked as VDC. Ratings Coil Single-winding Latching Type Must set Must reset Power Max voltage Rated current Coil resistance voltage voltage Rated Voltage consumption (mA) () (W) % of rated voltage 3 VDC 200 15 5 VDC 120 41.7 6 VDC 100 60 70% max. 70% max. 130% Approx. 0.6 12 VDC 50 240 24 VDC 25 960 Double-winding Latching Type Rated current Must set Must reset Power consumption Coil resistance () Max voltage (mA) voltage voltage (W) Rated Voltage Set coil Reset coil Set coil Reset coil % of rated voltage Set coil Reset coil 5 VDC 150 33.3 Approx. 0.75 12 VDC 62.5 192 70% max. 70% max. 130% 24 VDC 35 686 Approx. 0.84 Note. The rated current and resistance are measured at a coil temperature of 23C with a tolerance of 10%. 1- - G5RL-U/-K PCB Power Relay Contacts Load Resistive load Contact form SPST-NO (1a) SPDT (1c) Contact type Single Contact material Ag Alloy (Cd free) 16 A at 250 VAC (N.O) 16 A at 250 VAC 5 A at 250 VAC (N.C) Rated load 16 A at 24 VDC 16 A at 24 VDC (N.O) 5 A at 24 VDC (N.C) Rated carry current 16 A 16 A (N.O), 5A (N.C) Max. switching 250 VAC, 24 VDC voltage Max. switching 16 A 16 A (N.O), 5 A (N.C) current Characteristics Classification SPST-NO (1a), SPDT (1c) Item Relay function Single-winding Latching, Double-winding Latching Contact resistance *1 100 m max. Set time 10 ms max. Reset time 10 ms max. Minimum pulse width *2 30 ms Maximum pulse width *2 1 min Insulation resistance *3 1,000 M min. Between coil and 6,000 VAC, 50/60 Hz for 1 min contacts Dielectric strength Between contacts of 1,000 VAC, 50/60 Hz for 1 min G the same polarity 5 Impulse withstand Between coil and 10 kV (1.2 50 s) R voltage contacts L Between coil and Insulation distance Clearance: 6.4 mm, Creepage: 8 mm contacts U Destruction 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) / Vibration sesistanse 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) at Set status Malfunction K 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) at Reset status (Except SPST-NO) 2 Destruction 1,000 m/s 2 Shock resistance 150 m/s at Set status Malfunction 2 50 m/s at Reset status (Except SPST-NO) Mechanical *4 5,000,000 operations min. Durability Electrical *4 50,000 operations min. Ambient operating temperature -40 to 85C (with no icing or condensation) Ambient operating humidity 5% to 85% Weight Approx. 10 g Note. Values in the above table are initial values. *1. The contact resistance is measured with 1 A applied at 5 VDC using a fall-of-potential method. *2. These are measured at a coil temperature of 23C and rated coil voltage. Pulse duty factor should be 10% MAX. *3. The insulation resistance is measured between coil and contacts and between contacts of same polarity at 500 VDC. *4. Operated with input pulse width 30 ms. Engineering Data Maximum Switching Power Ambient Temperature vs. Malfunction Shock Maximum Coil Voltage Y 140 50 1,000 AC resistive Load (N.C.) 130 NO 800 120 16 600 X Z 10 100 400 5 200 80 200 DC resistive Load (N.C.) 60 400 1 Z X 600 40 0.5 Shock direction 800 X X Y 20 2 Z Unit: m/s 1,000 Y Z 0.1 0 Y 40 20 0 20 40 60 80 85 100 1 10 24 100 250 1000 Sample: G5RL-K1A-E 12VDC Ambient Temperature (C) Switching voltage (V) No. of relays: 5 pcs Note. Maximum voltage of Set pulse and Reset Test Conditions:Shock is applied in X, Y, and Z pulse at duty factor 10%. directions three times each with Set and Reset status to check the number of contact malfunctions. 2 Standard value:50 m/s with Set status 2 100 m/s with Reset status 2 Switching Current (A) Maximum voltage (%)