Low Signal Relay G5V-1 High sensitivity: 150 mW nominal power consumption with 96 mW pickup power Small size at 10 H x 7.5 W x 12.5 L mm (0.394 H x 0.295 W x 0.492 L in) Conforms to FCC part 68 voltage surge Fully-sealed construction Ideal for use in telecommunications, security, and computer/peripheral equipment Available in PCB through-hole, SMT gullwing high ambient versions and high dielectric versions Ordering Information To Order: Select the part number and add the desired coil voltage rating (e.g., G5V-1-DC12). Terminal Type Contact form Contact type Construction Part number PCB through-hole Standard SPDT Single crossbar Fully sealed G5V-1 Special pickup G5V-1-2 High dielectric G5V-1-HTY Surface mount gullwing Standard G5V-1F High dielectric G5V-1F-Y Note: Reflow solder process version is also available in PCB through-hole configuration. Please consult your local Omron sales representative for more information. Specifications CONTACT DATA Load Resistive load (p.f. = 1) Inductive load (p.f. = 0.4, L/R = 7ms) Rated load 0.50 A at 125 VAC, 1 A 24 VDC Contact material Ag (Au clad) Carry current 2 A Max. operating voltage 125 VAC, 60 VDC Max. operating current 1 A Max. switching capacity 62.50 VA, 30W Min. permissible load 1 mA, 5 VDCG5V-1 G5V-1 COIL DATA (G5V-1, G5V-1-2) Rated Rated Coil Coil inductance Pick-up Dropout Maximum Power voltage current resistance (Ref. value) (H) voltage voltage voltage consumption (VDC) (mA) ( ) (mW) Armature OFF Armature ON % of rated voltage 3 50 60 0.11 0.05 80% 10% min. 200% Approx. 150 at 55C 5 30 166.70 0.29 0.15 70% (131F) (special 6 25 240 0.41 0.20 pickup) 9 16.70 540 0.93 0.45 160% at 70C 12 12.50 960 1.63 0.85 (158F) 24 6.30 3,840 6.61 3.48 Note: 1. The rated current and coil resistance are measured at a coil temperature of 23C (73F) with a tolerance of 10% . 2. The operating characteristics are measured at a coil temperature of 23C (73F). COIL DATA (G5V-1-HTY, G5V-1F, G5V-1F-Y) Rated Rated Coil Coil inductance Pick-up Dropout Maximum Power voltage current resistance (Ref. value) (H) voltage voltage voltage consumption (VDC) (mA) ( ) (mW) Armature OFF Armature ON % of rated voltage 5 30 166.70 0.29 0.15 80% max. 10% min. 200% Approx. 150 at 55C 12 12.50 960 1.63 0.85 (131F) 24 8.3 2,880 4.95 2.61 Approx. 200 160% at 70C (158F) Note: 1. The rated current and coil resistance are measured at a coil temperature of 23C (73F) with a tolerance of 10% . 2. The operating characteristics are measured at a coil temperature of 23C (73F). CHARACTERISTICS Contact resistance 100 m max. Operate time 5 ms max. (mean value: approx. 2.50 ms) Release time 5 ms max. (mean value: approx. 0.90 ms) Bounce time 5 ms max. (mean value: approx. 0.17 ms) Operating frequency Mechanical 36,000 operations/hour Electrical 1,800 operations/hour Insulation resistance 1,000 M min. (at 500 VDC) Dielectric strength 1,000 VAC, 50/60 Hz for 1 minute between coil and contacts 1,500 VAC, 50/60 Hz for 1 minute between coil and contacts (high dielectric versions) 400 VAC, 50/60 Hz for 1 minute between contacts of same polarity Surge withstand voltage 1,500 V 10 X 160 s (conforms to FCC Part 68) Vibration Mechanical durability 10 to 55 Hz, 3.30 mm (0.13 in) double amplitude Malfunction durability 2 Shock Mechanical durability 1,000 m/s (approx. 100 G) 2 Malfunction durability 100 m/s (approx. 10 G) Ambient temperature -30C to 70C (-22F to 158F) for standard and special pickup PCB through-hole version -40C to 70C (-40F to 158F) for surface mount versions Humidity 35% to 85% RH Service life Mechanical 5 million operations min. (at 36,000 operations/hour) Electrical See Characteristic Data Weight 2.20 g (0.08 oz) Note: Data shown are of initial value. 2