G5V-1
Low Signal Relay
Ultra-miniature, Highly Sensitive
SPDT Relay for Signal Circuits
Ultra-miniature at 12.5 7.5 10 mm (L W H).
Wide switching power of 1 mA to 1 A.
High sensitivity: 150 mW nominal coil power consumption.
Fully-sealed construction offering environment resistance.
Conforms to FCC Part 68 requirements for coil to contacts.
(1,500 V, 10 160 s)
Models for ambient temperatures up to 90C added to series.
RoHS Compliant
Model Number Legend Application Examples
1. Number of Poles/Contact Form Telecommunication equipment
G5V-@-@
1: 1-pole/SPDT (1c) Audio-visual products
12
Security equipment
2. Classification
G
Building automation equipment
None: Standard (Ambient operating temperature 70C max.)
5
V
T90: Ambient operating temperature 90C max.
1
Ordering Information Standard Model Specifications
Contact type: Single crossbar (Au-alloy + Ag)
Enclosure Terminal Rated coil Minimum
Classification Contact form Model
rating Shape voltage packing unit
Enclosure rating: Plastic sealed
3 VDC
Terminal shape: PCB terminals
5 VDC
6 VDC
Standard G5V-1
9 VDC
Fully SPDT PCB
12 VDC 25 pcs/tube
sealed (1c) terminals
24 VDC
5 VDC
G5V-1-T90 G5V-1-T90 12 VDC
24 VDC
Note: When ordering, add the rated coil voltage to the model number.
Example: G5V-1 DC3
Rated coil voltage
However, the notation of the coil voltage on the product case as well as on the packing will be marked as @@ VDC.
Ratings
Coil Contacts
G5V-1 (Standard)
Load
Resistive load
Item
Must operate Must release
Rated Coil Max. voltage Power
Contact type Single crossbar
voltage voltage
Rated voltage current resistance (V) consumption
(V) (V) Contact
(mA) () (mW)
Au-alloy + Ag
% of rated voltage material
3 VDC 50 60
0.5 A at 125 VAC;
Rated load
5 VDC 30 167
1 A at 24 VDC
6 VDC 25 240
200% at
Rated carry
80% max. 10% min. Approx. 150
2 A
9 VDC 16.7 540 23C
current
12 VDC 12.5 960
Max. switching
125 VAC, 60 VDC
24 VDC 6.25 3,840
voltage
Max. switching
G5V-1-T90
1 A
current
Must operate Must release
Rated Coil Max. voltage Power
voltage voltage
Rated voltage current resistance (V) consumption
(V) (V)
(mA) () (mW)
% of rated voltage
5 VDC 30 167
200% at
12 VDC 12.5 960 70% max. 10% min. Approx. 150
23C
24 VDC 6.25 3,840
Note 1. The rated current and coil resistance are measured at a coil temperature of 23C with a tolerance
of 10%.
2.The operating characteristics are measured at a coil temperature of 23C.
3.The maximum voltage is the highest voltage that can be imposed on the relay coil.
4.G5V-1-2 types with a must operate voltage of 70% max. are available as special series products.
1-
G5V-1 Low Signal Relay
Characteristics
Contact resistance *1 100 m max.
Operate time 5 ms max.
Release time 5 ms max.
1,000 M min. (at 500 VDC between coil and contacts,
Insulation resistance *2
at 250 VDC between contacts of same polarity.)
Dielectric Between coil and contacts 1,000 VAC, 50/60 Hz for 1 min
strength Between contacts of the same polarity 400 VAC, 50/60 Hz for 1 min
Note: The values here are initial values.
10 to 55 to 10 Hz, 1.65 mm single amplitude
Destruction
*1. Measured with 10 mA at 1 VDC with a voltage drop
(3.3 mm double amplitude)
Vibration
method.
resistance
10 to 55 to 10 Hz, 1.65 mm single amplitude
Malfunction *2. Measured with a 500 VDC megohmmeter between
(3.3 mm double amplitude)
coil and contacts and a 250 VDC megohmmeter
2
Shock Destruction 1,000 m/s
between contacts with the same polarity applied to
2
resistance Malfunction 100 m/s
the same parts as those used for checking the
Mechanical 5,000,000 operations min. (at 36,000 operations/hr)
dielectric strength.
Durability 100,000 operations min.
*3. This value was measured at a switching frequency
Electrical
(under rated load, at 1,800 operations/hr)
of 120 operations/min and the criterion of contact
Failure rate (P level) (reference value) *3 1 mA at 5 VDC
resistance is 100 .
-40C to 70C (Standard), -40C to 90C (G5V-1-T90)
This value may vary depending on the switching
Ambient operating temperature
(with no icing or condensation)
frequency and operating environment. Always
Ambient operating humidity 5% to 85% double-check relay suitability under actual operating
Weight Approx. 2 g conditions.
G
5
V
1
2