G6D PCB Power Relay Slim, Miniature Relay, Capable of Relaying Programmable Controller and Temperature Controller Outputs Reduced board space, ideal for high-density mounting (45%. (6.5 mm (W) 17.5 mm (L) 12.5 mm (H)) Small, yet switches 5 A at 250 VAC/30 VDC. Allows 300,000 operations with a 2-A load at 250 VAC or 30 VDC. RoHS Compliant Model Number Legend Application Examples Ideal for output applications of control G6D- - - equipments. 12 3 4 G 6 1. Number of Poles 3. Contact Material D Characteristics 1: 1-pole ASI: Silver alloy (cadmium-free) 2. Contact Form Contact resistance *1 100 m max. A: SPST-NO (1a) 4. Contact surface Operate time 10 ms max. AP: Au plated Release time 5 ms max. Insulation resistance *2 1,000 M min. Ordering Information Between coil 3,000 VAC, 50/60 Hz for and contacts 1min Dielectric Between Minimun packing Enclosure rating Contact form Terminal shape Model Rated coil voltage strength contacts of unit 750 VAC, 50/60 Hz for the same 1min 5 VDC polarity G6D-1A-ASI 12 VDC Impulse withstand voltage Fully sealed SPST-NO (1a) PCB terminals 24 VDC 25 pcs/tube 6 kV (1.2 x 50 s) (between coil and contacts) 12 VDC G6D-1A-ASI-AP 10 to 55 to 10 Hz, 0.75 mm 24 VDC Destruction single amplitude (1.5 mm Note. When ordering, add the rated coil voltage to the model number. double amplitude) Vibration Example: G6D-1A-ASI 5 VDC resistance 10 to 55 to 10 Hz, 0.75 mm Rated coil voltage Malfunction single amplitude (1.5 mm double amplitude) Connecting Socket 2 Destruction 1,000 m/s Shock Applicable relay Model Minimun packing unit 2 resistance Malfunction 100 m/s G6D-1A-ASI P6D-04P 25 pcs 20,000,000 operations min. Mechanical (at 18,000 operations/hr) 70,000 operations min. Ratings (5 A at 250 VAC, resistive load) Coil 70,000 operations min. Item Must operate Must release Max. (5 A at 30 VDC, resistive Rated Coil Power Durability load) voltage voltage voltage current resistance consumption Electrical 300,000 operations min. (V) (V) (V) (mA) () (mW) (2 A at 250 VAC, resistive Rated voltage % of rated voltage load) 5 VDC 40 125 160% 30,000 operations min. 12 VDC 16.7 720 70% max.* 10% min. Approx. 200 (at 23C) (2 A at 30 VDC, resistive 24 VDC 8.3 2,880 load) Note 1. The rated current and coil resistance are measured at a coil temperature of 23C with a tolerance of (at 18,000 operations/hr) 10%. Failure rate (P level) 10 mA at 5 VDC *2. The operating characteristics are measured at a coil temperature of 23C. (reference value *3) (1 mA at 5 VDC) *4 *3. The Max. voltage is the maximum voltage that can be applied to the relay coil. Ambient operating -25C to 70C (with no icing * The must operate voltage is 75% or less of the rated voltage if the relay is mounted upside down. temperature or condensation) Ambient operating humidity 5% to 85% Contacts Weight Approx. 3 g Item Load Resistive load Note. The data given above are initial values. Contact Type Single *1. Measurement conditions: 5 VDC, 1 A, voltage Ag-Alloy (Cd free) Contact material drop method. (Ag-alloy (Cd free) and Au plated) *2. Measurement conditions: The insulation 5 A at 250 VAC resistance was measured with a 500 VDC Rated load 5 A at 30 VDC megohmmeter at the same locations as the Rated carry current 5 A dielectric strength was measured. *3. This value was measured at a switching Max. switching voltage 250 VAC, 30 VDC frequency of 120 operations/min. Max. switching current 5 A *4. The values indicated in parentheses ( ) are * The content indicated in parentheses ( ) are for the G6D-1A-ASI-AP. for the G6D-1A-ASI-AP. 1G6D PCB Power Relay Engineering Data Maximum Switching Capacity Durability Ambient Temperature vs. Maximum Coil Voltage 500 50 200 300 30 180 100 10 160 AC resistive load 250 VAC/30 VDC resistive load 50 5 140 30 3 DC resistive load 120 AC inductive 10 1 load DC inductive load cos=0.4 100 250 VAC/30 VDC inductive load 5 0.5 (cos=0.4/ L/R=7 ms) 3 0.3 80 60 0.1 0 1 2 3 4 5 6 7 8 9 10 0 3 5 10 30 100 250 500 1,000 0 23 30 40 50 60 70 80 90 Switching current (A) Ambient temperature (C) Switching voltage (V) Note. The maximum coil voltage is the maximum voltage that can be applied to the relay coil. Ambient Temperature vs. Must Shock Malfunction Operate and Must Release G6D-1A-ASI (-AP) Voltages G6D-1A-ASI (-AP) G Y 100 1,000 6 Sample: G6D-1A-ASI Must Operating voltage Number of Relays: Must Recovery voltage D 800 5 pcs 80 600 X Z 400 max. 200 X 60 min. 206 40 Z X Shock direction max. X X X 20 De-energized Y min. Z 2 Y Energized Unit: m/s Z Y 0 -40 -20 0 20 40 60 80 Coil terminals Ambient temperature (C) Sample: G6D-1A-ASI 24 VDC Number of Relays: 5 pcs Test conditions: Impose a shock in the X, Y, and Z directions three times each with the Relay energized to check the shock values that cause the Relay to malfunction. Dimensions PCB Mounting Holes Terminal Arrangement/ G6D-1A-ASI (-AP) (Bottom View) Internal Connections 6.5 max. (Bottom View) (6.4)* 17.5 max. 0.5 2.54 (17.3)* Four, 1.1-dia. (0.71) 12.5 max. 1 57 (12.4)* 2.54 5.08 3.5 13 (No coil polarity) 0.5 0.8 0.3 5.08 (1.13) 10.16 2.54 7.62 5.08 5.08 Note: Orientation marks are indicated as follows: * Average value 19.7 max. PCB Mounting Holes Socket (19.5)* (Bottom View) P6D-04P 6.9 max. 2.54 Four, 1.1-dia. (6.7)* (0.86) 2.54 10.8 5.08 0.1 6 3.6 5.08 (2.18) 10.16 0.65 0.3 2.54 7.62 5.08 * Average value 2 Must operate and must release voltage (ratio of rated voltage) (%) Switching current (A) 4 Durability (x10 operations) Maximum coil voltage (%)