Surface-mounting Relay
G6J-Y
Ultra-compact and Slim DPDT Relay
Dimensions of 9H x 5.7W x 10.6L mm provide a mounting
area reduction of approx. 56% when compared with the
OMRON G6S.
Dielectric strength of 1,500 VAC and an impulse withstand
voltage of 2,500 V for 2 x 10 s
(conforms to Telcordia specifications (formerly Bellcore)).
Conforms to FCC Part 68 requirments (1,500 V,10 x 160 s).
Single-winding latching models to save energy.
UL recognized / CSA certified.
RoHS Compliant.
Ordering Information
Item Model
Terminal Contact form Non-latching Single coil latching
PCB through-hole DPDT G6J-2P-Y G6JU-2P-Y
SMT Gull-wing G6J-2FL-Y G6JU-2FL-Y
SMT Shortened leads G6J-2FS-Y G6JU-2FS-Y
.
Note 1: When ordering, add the rated coil voltage to the model number.
Example: G6J-2P-Y DC12
Rated coil voltage
Note 2: When ordering tape packing, add -TR to the model number.
Example: G6J-2P-Y-TR DC12
Rated coil voltage
-TR is not part of the relay model number. Therefore it is not marked on the relay case.
Model Number Legend:
G6J - - Y - DC
1 2 3 4 5
1. Relay Function 4. Packaging
None: Non-latching, standard
None: Tube packaging
U: Single-winding latching
TR: Tape and reel packaging
2. Contact Form 9. Rated Coil Voltage
2: DPDT
3, 4.5, 5, 12, 24
3. Terminal Shape
P: PCB through-hole terminals
FL: SMT Gull-wing
FS: SMT shortened leads
Application Examples
Communications equipment, measurement devices, computer peripheral devices, office automation equipment, and audio-visual products.
Surface-mounting Relay G6J-Y 43Specifications
Contact Data
Rated load 0.3 A @ 125 VAC
1 A @ 30 VDC
Contact material Ag (Au Clad)
Max. carry current 1 A
Max. operating voltage 125 VAC, 110 VDC
Max. operating current 1 A
Max. switching capacity 37.5 VA, 30 W
Min. permissible load (see note) 10m VDC, 10A
Note: This value was measured at a switching frequency of 120 operations/min and the criterion of contact resistance is 5% of the load impedance.
This value may vary depending on the operating frequency, operating conditions, expected reliability level of the relay, etc. Always double-
check relay suitability under actual load conditions.
Coil Data
G6J-Y Standard, Non-latching (G6J-2P-Y, G6J-2FS-Y, G6J-2FL-Y)
Rated voltage Rated current Coil resistance Pick-up voltage Drop-out Max. voltage Power
(VDC) (mA) () voltage consumption (mW)
% of rated voltage
3 48.0 62.5 75% max. 10% min. 150% max. 140
4.5 32.6 137.9
5 28.9 173.1
12 12.3 976.8
24 9.2 2,600.5 230
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23C with a tolerance of 10%.
2. The operating characteristics are measured at a coil temperature of 23C.
3. The maximum voltage is the highest voltage that can be imposed on the Relay coil instantaneously.
G6JU-Y Single coil, Latching (G6JU-2P-Y, G6JU-2FL-Y, G6JU-2FS-Y)
Rated voltage Rated current Coil resistance Set voltage Reset voltage Max. voltage Power
(VDC) (mA) () consumption (mW)
% of rated voltage
3 33.7 89.0 75% max. 75% max. 150% max. 100
4.5 22.0 204.3
5 20.4 245.5
12 9.0 1,329.2
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23C with a tolerance of 10%.
2. The operating characteristics are measured at a coil temperature of 23C.
3. The maximum voltage is the highest voltage that can be imposed on the Relay coil instantaneously.
44 Surface-mounting Relay G6J-Y