Surface-mounting Relay G6J-Y Ultra-compact and Slim DPDT Relay Dimensions of 9H x 5.7W x 10.6L mm provide a mounting area reduction of approx. 56% when compared with the OMRON G6S. Dielectric strength of 1,500 VAC and an impulse withstand voltage of 2,500 V for 2 x 10 s (conforms to Telcordia specifications (formerly Bellcore)). Conforms to FCC Part 68 requirments (1,500 V,10 x 160 s). Single-winding latching models to save energy. UL recognized / CSA certified. RoHS Compliant. Ordering Information Item Model Terminal Contact form Non-latching Single coil latching PCB through-hole DPDT G6J-2P-Y G6JU-2P-Y SMT Gull-wing G6J-2FL-Y G6JU-2FL-Y SMT Shortened leads G6J-2FS-Y G6JU-2FS-Y . Note 1: When ordering, add the rated coil voltage to the model number. Example: G6J-2P-Y DC12 Rated coil voltage Note 2: When ordering tape packing, add -TR to the model number. Example: G6J-2P-Y-TR DC12 Rated coil voltage -TR is not part of the relay model number. Therefore it is not marked on the relay case. Model Number Legend: G6J - - Y - DC 1 2 3 4 5 1. Relay Function 4. Packaging None: Non-latching, standard None: Tube packaging U: Single-winding latching TR: Tape and reel packaging 2. Contact Form 9. Rated Coil Voltage 2: DPDT 3, 4.5, 5, 12, 24 3. Terminal Shape P: PCB through-hole terminals FL: SMT Gull-wing FS: SMT shortened leads Application Examples Communications equipment, measurement devices, computer peripheral devices, office automation equipment, and audio-visual products. Surface-mounting Relay G6J-Y 43Specifications Contact Data Rated load 0.3 A 125 VAC 1 A 30 VDC Contact material Ag (Au Clad) Max. carry current 1 A Max. operating voltage 125 VAC, 110 VDC Max. operating current 1 A Max. switching capacity 37.5 VA, 30 W Min. permissible load (see note) 10m VDC, 10A Note: This value was measured at a switching frequency of 120 operations/min and the criterion of contact resistance is 5% of the load impedance. This value may vary depending on the operating frequency, operating conditions, expected reliability level of the relay, etc. Always double- check relay suitability under actual load conditions. Coil Data G6J-Y Standard, Non-latching (G6J-2P-Y, G6J-2FS-Y, G6J-2FL-Y) Rated voltage Rated current Coil resistance Pick-up voltage Drop-out Max. voltage Power (VDC) (mA) () voltage consumption (mW) % of rated voltage 3 48.0 62.5 75% max. 10% min. 150% max. 140 4.5 32.6 137.9 5 28.9 173.1 12 12.3 976.8 24 9.2 2,600.5 230 Note: 1. The rated current and coil resistance are measured at a coil temperature of 23C with a tolerance of 10%. 2. The operating characteristics are measured at a coil temperature of 23C. 3. The maximum voltage is the highest voltage that can be imposed on the Relay coil instantaneously. G6JU-Y Single coil, Latching (G6JU-2P-Y, G6JU-2FL-Y, G6JU-2FS-Y) Rated voltage Rated current Coil resistance Set voltage Reset voltage Max. voltage Power (VDC) (mA) () consumption (mW) % of rated voltage 3 33.7 89.0 75% max. 75% max. 150% max. 100 4.5 22.0 204.3 5 20.4 245.5 12 9.0 1,329.2 Note: 1. The rated current and coil resistance are measured at a coil temperature of 23C with a tolerance of 10%. 2. The operating characteristics are measured at a coil temperature of 23C. 3. The maximum voltage is the highest voltage that can be imposed on the Relay coil instantaneously. 44 Surface-mounting Relay G6J-Y