G6K(U)-2F(P)-RF(-S, -T)
Surface-mounting High-frequency Relay
Surface-mounting, 1-GHz-Band/
3-GHz-Band, Miniature, DPDT,
High-frequency Relay
Superior high-frequency characteristics (at 1 GHz), such as an isolation
of 20 dB min. between contacts of the same polarity of 30 dB min. be-
tween contacts of different polarity with an insertion loss of 0.2 dB max.
Miniaturized to 10.3 6.9 5.4 mm (L W H).
Rated power consumption of 100 mW with high sensitivity
Single-side stable and single-winding latching models are available.
Models with a smaller footprint (G6K(U)-2F-RF-S) are available to help save space.
G6K(U)-2F-RF-T models for 3-GHz band join the lineup with a downsized footprint.
New PCB terminals models are available.
RoHS Compliant
Model Number Legend Application Examples
Communications equipment
G
G6K@-@@-@-@
6
Broadcasting and audio-visual equipment
1234 5
K
Test & measurement equipment
1. Relay Function 4. Special Function
U
None: Single-side stable RF: High-frequency compatible
2
U: Single-winding latching
F
5. Terminal Shape
2. Number of poles/ None: Standard P
Contact Form S: Small footprint
R
2: 2-pole/ DPDT (2c) T: Compatible with 3 GHz
F
3. Terminal Shape
S
,
F: Outside-L surface mount-
T
ing terminals
P: PCB terminals
Ordering Information
Standard Models with Surface-mounting Terminals
Standard Specifications
Relay Function Enclosure rating Contact form Model Rated coil voltage Minimum packing unit
Single-side stable DPDT G6K-2F-RF 3, 4.5, 5, 12, 24 VDC 300 pcs/tray
Fully sealed
(2c) 300 pcs/reel
Single-winding latching G6KU-2F-RF 3, 4.5, 5, 12, 24 VDC
Board space-saving model
Relay Function Enclosure rating Contact form Model Rated coil voltage Minimum packing unit
Single-side stable G6K-2F-RF-S 3, 4.5, 5, 12, 24 VDC
DPDT 300 pcs/tray
Fully sealed
Single-winding latching (2c) G6KU-2F-RF-S 3, 4.5, 5, 12, 24 VDC 300 pcs/reel
Compatible with 3 GHz
Relay Function Enclosure rating Contact form Model Rated coil voltage Minimum packing unit
Single-side stable G6K-2F-RF-T 3, 4.5, 5, 12, 24 VDC
DPDT 300 pcs/tray
Fully sealed
(2c) 300 pcs/reel
Single-winding latching G6KU-2F-RF-T 3, 4.5, 5, 12, 24 VDC
PCB terminals
Relay Function Enclosure rating Contact form Model Rated coil voltage Minimum packing unit
Single-side stable Fully sealed DPDT (2c) G6K-2P-RF 3, 4.5, 5, 12, 24 VDC 30 pcs/tube
Note 1. When ordering, add the rated coil voltage to the model number.
Example: G6K-2F-RF DC3
Rated coil voltage
However, the notation of the coil voltage on the product case as well as on the packing will be marked as @@ VDC.
Note 2. When ordering Relays in tape packing, add-TR03" to the end of the model number.
Example: G6K-2F-RF-TR03 DC3
Relays per reel: 300 pcs for -TR03
Be sure since-T is not part of the relay model number, it is not marked on the relay case.
When ordering tape packing, minimum order unit is 1 reel (300 pcs 1 = 300 pcs).
Note 3. Surface mounting terminal (SMT) standard models are shipped in moisture-proof package.
PCB terminal standard types do not require moisture proof packaging and therefore shipped in non-moisture-proof package.
1( )- ( )- (- - )
G6K(U)-2F(P)-RF(-S, -T) Surface-mounting High-frequency Relay
Ratings
Coil: Single-side Stable (G6K-2F(P)-RF(-S, -T))
Must operate voltage Must release voltage Maximum voltage
Item Rated current Coil resistance Power consumption
(V) (V) (V)
(mA) ( ) (mW)
Rated voltage % of rated voltage
3 VDC 33.0 91
4.5 VDC 23.2 194
5 VDC 21.1 237 80% max. 10% min. 150% Approx. 100
12 VDC 9.1 1,315
24 VDC 4.6 5,220
Coil: Single-winding Latching Models (G6KU-2F-RF(-S, -T))
Must set voltage Must reset voltage Maximum voltage
Item Rated current Coil resistance Power consumption
(V) (V) (V)
(mA) ( ) (mW)
Rated voltage % of rated voltage
3 VDC 33.0 91
4.5 VDC 23.2 194
5 VDC 21.1 237 75% max. 75% max. 150% Approx. 100
12 VDC 9.1 1,315
24 VDC 4.6 5,220
Note 1. The rated current and coil resistance are measured at a coil temperature of 23C with a tolerance of 10%.
Note 2. The operating characteristics are measured at a coil temperature of 23C.
Note 3. The maximum voltage is the highest voltage that can be imposed on the Relay coil instantaneously.
Contacts High-frequency Characteristics *1
Item Load Resistive load Model G6K(U)-2F(P)-RF(-S) G6K(U)-2F-RF-T
125 VAC, 0.3 A Item Frequency 1GHz 1GHz 3GHz
G
Rated load 30 VDC, 1 A
Between
6
1 GHz, 1 W *
contacts of
K
20 dB min. 20 dB min. 18 dB min.
Rated carry current 1 A the same
U
polarity
Max. switching voltage 125 VAC or 60 VDC
Isolation
Between
Max. switching current 1A
2
contacts of
F
* This value is for a V.SWR of 1.2 max. at the load. 30 dB min. 30 dB min. 25 dB min.
different
P
polarity
Insertion loss 0.2 dB max. 0.2 dB max. 0.6 dB max.
R
V.SWR 1.2 max. 1.2 max. 1.4 max.
F
Maximum carry power 3W *2
S
, Maximum switching power 1W *2
Note 1. The impedance of the measurement system is 50 .
T
Note 2. The above values are initial values.
*1. Contact your OMRON representative if the Relay will be used in an
application that requires high repeatability in high-frequency
characteristics for the microload region. (Such applications include
testing and measurement equipment and ATE applications.)
*2. These values are for a V.SWR of 1.2 max. at the load.
Characteristics
Relay Function Single-side stable models Single-winding latching models
Item Model G6K-2F(P)-RF(-S, -T) G6KU-2F-RF(-S, -T)
Contact resistance *1 100 m max.
Operating (set) time *2 3 ms max. (approx. 1.4 ms) 3 ms max. (approx. 1.2 ms)
Release (reset) time *2 3 ms max. (approx. 1.3 ms) 3 ms max. (approx. 1.2 ms)
Minimum set/reset pulse time --- 10 ms
Insulation resistance *3 1,000 M min. (at 500 VDC)
Between coil and
750 VAC, 50/60 Hz for 1 min
contacts
Between contacts of
750 VAC, 50/60 Hz for 1 min
Dielectric different polarity
strength Between contacts of the
750 VAC, 50/60 Hz for 1 min
same polarity
Between ground and
500 VAC, 50/60 Hz for 1 min
coil/contacts
2
Destruction 10 to 55 to 10 Hz, 2.5 mm single amplitude (5 mm double amplitude) and 55 to 500 Hz, 300 m/s
Vibration
2
resistance
Malfunction 10 to 55 to 10 Hz, 1.65 mm single amplitude (3.3 mm double amplitude) and 55 to 500 Hz, 200 m/s
2
Destruction 1,000 m/s
Shock
2
resistance
Malfunction 750 m/s
Mechanical 50,000,000 operations min. (at a switching frequency of 36,000 operations/hour)
Durability
Electrical 100,000 operations min. (at a switching frequency of 1,800 operations/hour)
Ambient operating temperature -40C to 70C (with no icing or condensation)
Ambient operating humidity 5% to 85%
Weight Approx. 0.95 g
Note. The above values are initial values.
*1. The contact resistance was measured with 10 mA at 1 VDC with a voltage drop method.
*2. Values in parentheses are actual values.
*3. The insulation resistance was measured with a 500 VDC megohmmeter applied to the same parts as those used for checking the dielectric strength.
2