G6L Surface-mounting Relay Extremely Thin SPST-NO Flat Relay, One of the Thinnest Relays in the World Dimensions of 7.0 (W) 10.6 (L) 4.5 mm (H) (SMD) or 4.1 mm (H) (TH) represent a reduction of approximately 20% in mounting area and approximately 64% in volume compared with the OMRON G5V-1, for higher-density mounting. Ensures a dielectric strength between coil and contacts (1,000 VAC), and conforms to FCC Part 68 (i.e., withstanding an impulse withstand voltage of 1.5 kV for 10 160 s). High dielectric strength between contacts of same polarity (750 VAC). Surface-mounting relays are also available. Standard model conforms to UL/CSA standards. Use of lead completely eliminated. RoHS Compliant G 6 L Model Number Legend Application Examples Peripherals of MODEM/PC G6L-1 Telephones 12 Office automation machines 1. Number of poles/ Contact form Audio-visual products 1: 1-pole/SPST-NO (1a) Communications equipment Measurement devices 2. Terminal shape Amusement equipment P: PCB terminals Security equipment F: Surface-mounting terminals Ordering Information Surface-mounting Relay Standard Models (UL, CSA) Minimum ordering unit Classification Relay Function Enclosure rating Contact form Model Rated coil voltage Minimum packing unit (tape packing) 3 VDC 45 VDC G6L-1P 5 VDC 50 pcs/tube 12 VDC 24 VDC SPST-NO Standard Single-side stable Fully sealed 1000 pcs/reel (1a) 3 VDC 45 VDC 50 pcs/tube G6L-1F 5 VDC (1,000 pcs/reel) 12 VDC 24 VDC Note 1. When ordering, add the rated coil voltage to the model number. Example: G6L-1P 3 VDC Rated coil voltage Note 2. When ordering tape packing, add -TR to the model number. Be sure since -TR is not part of the relay model number, it is not marked on the relay case. (Otherwise, the Relays in tube packing will be provided.) 1G6L Surface-mounting Relay Ratings Coil: Single-side stable Relays (G6L-1P, G6L-1F) Item Must operate voltage Must release voltage Maximum voltage Rated current Coil resistance Power consumption (V) (V) (V) (mA) () (mW) Rated voltage % of rated voltage 3 VDC 60.0 50.0 4.5 VDC 40.0 112.5 150% Approx. 180 5 VDC 36.0 139.0 75% max. 10% min. 12 VDC 15.0 800.0 24 VDC 9.6 2,504.0 130% Approx. 230 Note 1. The rated current and coil resistance are measured at a coil temperature of 23C with a tolerance of 10%. Note 2. The operating characteristics are measured at a coil temperature of 23C. Note 3. The maximum voltage is the highest voltage that can be imposed on the relay coil. Note 4. The voltage measurements for operate/release are the values obtained for instantaneous changes in the voltage (rectangular wave). Contacts Item Load Resistive load Contact type Single crossbar Contact material Ag (Au-alloy surface) 0.3 A at 125 VAC, Rated load 1 A at 24 VDC Rated carry current 1 A Max. switching voltage 125 VAC, 60 VDC G 6 Max. switching current 1 A L Characteristics Classification Single-side Stable Relays Item Model G6L-1P, G6L-1F Contact resistance *1 100 m max. Operating time 5 ms max. Release time 5 ms max. Insulation resistance *2 1,000 M min. (at 500 VDC) Between coil and 1,000 VAC, 50/60 Hz for 1 min contacts Dielectric strength Between contacts of 750 VAC, 50/60 Hz for 1 min same polarity Impulse Between coil and withstand 1,500 VAC, 10 160 s contacts voltage Destruction 10 to 55 Hz, 1.65 mm single amplitude (3.3 mm double amplitude) Vibration resistance Malfunction 10 to 55 Hz, 1.65 mm single amplitude (3.3 mm double amplitude) 2 Destruction 1,000 m/s Shock resistance 2 Malfunction 100 m/s Mechanical 5,000,000 operations min. (at 36,000 operations/hour) Durability Electrical 100,000 operations min. (with a rated load at 1,800 operations/hour) Failure rate (P level) *3 1 mA at 5 VDC Ambient temperature Operating: -40C to 70C (with no icing or condensation) Ambient humidity Operating: 5% to 85% Weight Approx. 0.6 g Note: The above values are initial values. *1. The contact resistance was measured with 10 mA at 1 VDC with a fall-of-potential method. *2. The insulation resistance was measured with a 500 VDC Megger Tester applied to the same parts as those used for checking the dielectric strength. *3. This value was measured at a switching frequency of 120 operations/min. This value may vary, depending on switching frequency, operating conditions, expected reliability level of the relay, etc. It is always recommended to double-check relay suitability under actual load conditions. 2