G6RL PCB Power Relay Low-profile 12.3 mm height power relay with maximum switching of 10A Low profile: 12.3 mm in height Max. switching capacity: 2,500 VA (NO) Dielectric strength: 5 kV Clearance and creepage distance: 10 mm. 2 Models with high shock resistance (250 m/s ) are available. Models for P1 load (2 x 200 W lamps parallel to ignition transformer) are available. RoHS Compliant Model Number Legend G6RL- - - - 12 3 4 5 6 G 1. Number of Poles 3. Enclosure rating 5. Contact material 6 1: 1-pole None: Flux protection None: Standard (Ag-alloy, Cd free) R L 4: Fully sealed ASI: AgSnIn 2. Contact Form None: SPDT (1c) 4. Special Function 6. Special Functions A: SPST-NO (1a) SR: Shock resistance of 25G PL: P1 load Application Examples Boilers PLCs I/O ports Timers Temperature controllers Ordering Information Classification Terminal Shape Contact form Enclosure rating Model Rated coil voltage Minimum packing unit G6RL-1A Standard G6RL-1A-ASI Flux protection SPST-NO (1a) 3 VDC P1 Load G6RL-1A-ASI-PL 5 VDC Fully sealed G6RL-1A4-ASI 6 VDC Standard G6RL-1 12 VDC PCB terminals 100 pcs/tray G6RL-1-ASI 24 VDC Flux protection (48 VDC) P1 Load G6RL-1-ASI-PL SPDT (1c) Shock resistance G6RL-1-SR-ASI ( ): Except -SR Standard G6RL-14-ASI Fully sealed Shock resistance G6RL-14-SR-ASI Note. When ordering, add the rated coil voltage to the model number. Example: G6RL-1A 3 VDC Rated coil voltage Ratings Coil Standard, P1 Load (-PL type) Must operate voltage Must release voltage Max. voltage Rated Voltage Rated current Coil resistance Power consumption (V) (V) (V) (VDC) (mA) () (mW) % of rated voltage 3 73.3 40 5 44 113 6 36.7 Approx. 220 163 150% 70% max. 10% min. (at 23C) 12 18.3 654 24 9.2 2618 48 5 Approx. 240 9600 1G6RL PCB Power Relay Must operate voltage Must release voltage Max. voltage Rated Voltage Rated current Coil resistance Power consumption (V) (V) (V) (VDC) (mA) () (mW) % of rated voltage 3 101 30 5 60.2 83 150% 6 50.1 80% max. 10% min. Approx. 300 120 (at 23C) 12 25.2 476 24 12.6 1912 Note 1. The rated current and coil resistance are measured at a coil temperature of 23C with a tolerance of 10%. Note 2. The operating characteristics are measured at a coil temperature of 23C. Note 3. The Max. voltage is the maximum voltage that can be applied to the relay coil. Contacts Load Resistive load Contacts type Single Contacts material Ag-alloy (Cd free) 10 A at 250 VAC, (NO) resistive load Rated load * 8 A at 250 VAC, resistive load 5 A at 30 VDC, resistive load Rated carry current 10 A Max. switching current NO: 10 A, NC: 8 A * G6RL-1(A), G6RL-1(A)4-ASI: 8 A 250 VAC, resistive load 5 A 24 VDC resistive load. Characteristics Contact resistance *1 100 m max. Operate time 10 ms max. (SR Models: 15 ms max.) Release time 5 ms max. Insulation resistance *2 1,000 min. (at 500 VDC) Between coil and contacts 5,000 VAC, 50/60 Hz for 1 min G Dielectric strength Between contacts of the same polarity 1,000 VAC, 50/60 Hz for 1 min 6 Impulse withstand voltage Between coil and contacts 10kV (1.250s) R Destruction 10 to 55 to 10 Hz, 0.75 mm single amplitude (1.5 mm double amplitude) L Vibration resistance 10 to 55 to 10 Hz, 0.825 mm single amplitude (1.65 mm double amplitude) when energized Malfunction 10 to 55 to 10 Hz, 0.4 mm single amplitude (0.8 mm double amplitude) when de-energized. 2 Destruction 1,000 m/s Shock resistance 2 2 Malfunction NO: 200 m/s , NC: 50 m/s Mechanical 10,000,000 operations min. (at 18,000 operations/h) G6RL-1(A) 50,000 operations min. (NO) at 250 VAC, 8A (resistive load) 50,000 operations min. (NC) at 250 VAC, 8A (resistive load) 50,000 operations min. at 24 VDC, 5A (resistive load) (at 600 operations/h) G6RL-1(A)-(SR)-ASI-(PL) 100,000 operations min. (NO) at 250 VAC, 10A (resistive load) 100,000 operations min. at 250 VAC, 8A (resistive load) 50,000 operations min. at 30 VDC, 5A (resistive load) (at 1,800 operations/h) Endurance Electrical G6RL-1(A)4-ASI 50,000 operations min. (NO) at 250 VAC, 8A (resistive load) 50,000 operations min. (NC) at 250 VAC, 8A (resistive load) 50,000 operations min. at 24 VDC, 5A (resistive load) (at 1,800 operations/h) G6RL-14-SR-ASI 50,000 operations min. (NO) at 250 VAC, 8A (resistive load) 100,000 operations min. (NC) at 250 VAC, 3A (resistive load) 50,000 operations min. (NO) at 24 VDC, 5A (resistive load) 30,000 operations min. (NC) at 24 VDC, 5A (resistive load) (at 1,800 operations/h) Failure rate (P level) (reference value) *3 10 mA at 5 VDC Ambient operating temperature -40C to 85C (with no icing or condensation) Ambient operating humidity 5% to 85% Weight Approx. 7.8 g Note. The given values are initial values. *1. Measurement conditions: 5 VDC, 1 A, voltage drop method. *2. Measurement conditions: The insulation resistance was measured with a 500 VDC megohmmeter at the same locations as the dielectric strength was measured. *3. This value was measured at a switching frequency of 120 operations/min. Other data Enclosure rating Flux protection Fully sealed Insulation material group IIIa Rated Insulation Voltage 250 V Pollution degree 3 2 Rated voltage system 250 V 400 V Overvoltage category III Creepage distance 10 mm Clearance distance 10 mm RoHS Compliant Tracking Index of relay base PTI 250 Flammability class according to UL94 V-0 GWFI (IEC 60695-2-12) 850C Flammability-flame GWIT (IEC 60695-2-13) 750C Ball pressure test (IEC 60695-10-2) 170C 2