G6RN PCB Power Relay Miniature Power Relay for Switching 8 A Low-profile height of 15 mm (approx. 60% the height of the Omron G2R model). Capable of switching with 8 A at 250 VAC despite its small size. High sensitivity with 220mW power consumption. Offers high insulation with insulation distance of 8 mm and impulse withstand voltage of 10kV between coil and contacts. Satisfies ambient operating temperature requirement of 85C. Standard model conforms to VDE standards. RoHS Compliant Model Number Legend Application Examples Control equipments G6RN- G 12 Characteristics 6 1. Number of Poles 2. Contact Form R 1: 1-pole None: SPDT (1c) Contact resistance *1 100 m max. N A: SPST-NO (1a) Operate time 15 ms max. Release time 5 ms max. 1,000 M min. Ordering Information Insulation resistance *2 (at 500 VDC) Between Enclosure Rated coil Minimun coil and 4,000 VAC, 50/60 Hz for 1 min Classification Contact form Terminal shape Model rating voltage packing unit contacts Dielectric 5, 6, 12 VDC Between SPST-NO (1a) G6RN-1A strength PCB 24 VDC contacts of Standard Fully sealed 20 pcs/tube 1,000 VAC, 50/60 Hz for 1 min the same terminals 5, 6, 12 VDC SPDT (1c) G6RN-1 polarity 24 VDC Impulse withstand Note. When ordering, add the rated coil voltage to the model number. voltage (between coil 10,000 V (1.2 x 50 s) Example: G6RN-1A 5 VDC and contacts) Rated coil voltage 10 to 55 to 10 Hz, 0.75 mm Destruction single amplitude (1.5 mm double amplitude) Ratings Vibration 10 to 55 to 10 Hz resistance NO: 0.75 mm single amplitude Coil Malfunction (1.5 mm double amplitude) Item Must operate Must release Max. NC: 0.4 mm single amplitude Rated Coil Power voltage voltage voltage (0.8 mm double amplitude) current resistance consumption 2 (V) (V) (V) Destruction 1,000 m/s (mA) () (mW) Shock 2 Rated voltage % of rated voltage NO: 100 m/s resistance Malfunction 2 NC:: 50 m/s 5 VDC 43.9 114 10,000,000 operations min. 6 VDC 36.6 164 150% Mechanical 70% max. 10% min. Approx. 220 (at 36,000 operations/hr) (at 23C) 12 VDC 18.3 655 50,000 operations min. 24 VDC 9.2 2,620 (8 A at 250 VAC, resistive load) Durability Note 1. The rated current and coil resistance are measured at a coil temperature of 23C with a tolerance of 50,000 operations min. Electrical *3 10%. (5 A at 30 VDC, resistive load) *2. The operating characteristics are measured at a coil temperature of 23C. (at 360 operations/hr under *3. The Max. voltage is the maximum voltage that can be applied to the relay coil. rated load) Failure rate (P level) Contacts 10 mA at 5 VDC (reference value) *4 Load Ambient operating -40C to 85C (with no icing or Resistive load Item temperature condensation) Contact type Single Ambient operating 5% to 85% Ag-Alloy + gold plating humidity Contact material (Cd free) Weight Approx. 9 g 8 A at 250 VAC Note. The data given above are initial values. Rated load 5 A at 30 VDC *1. Measurement conditions: 5 VDC, 1 A, voltage drop Rated carry method. 8 A current *2. Measurement conditions: The insulation resistance Max. switching was measured with a 500 VDC megohmmeter at the 250 VAC, 30 VDC voltage same locations as the dielectric strength was Max. switching measured. 8 A current *3. Test conditions: With diode *4. This value was measured at a switching frequency of 120 operations/min. 1G6RN PCB Power Relay Engineering Data Maximum Switching Capacity Durability Ambient Temperature vs. Maximum Coil Voltage 100 200 250 VAC resistive load 50 30 VDC resistive load 50 180 30 AC resistive load 30 DC resistive load 160 10 8 150 5 140 3 10 130 120 1 5 110 100 0.5 3 0.3 80 0.1 1 0 0 3 5 10 30 50 100 250 500 0 2 4 6 8 10 -40 20 23 30 40 50 60 70 80 90 100 Switching Voltage (V) Switching Current (A) Ambient Temperature (C) Note. The maximum coil voltage refers to the maximum value in a varying range of operating power voltage, not a continuous voltage. Ambient Temperature vs. Shock Malfunction Maximum Coil Voltage G6RN-1 Y 100 1,000 Must operate voltage Sample: G6RN-1 24 VDC Sample: contact A Must release voltage G6RN-1 12 VDC Number of Relays: 5 pcs Number of Relays: Test conditions: The value at which G 5 pcs 80 malfunction occurred was measured X Z 6 max. 1,000 1,000 after applying shock to the test piece 3 X R min. times each in 6 directions along 3 axes. N 60 2 Standard value: 100m/s at contact A, 88.2 contact B 2 50m/s at contact B 40 1,000 1,000 Z X max. X 20 Shock direction min. XX 1,000 2 Y Unit: m/s Y Z 0 Z -40 -20 0 20 40 60 80 100 Y Ambient Temperature (C) Dimensions PCB Mounting Holes Terminal Arrangement/ G6RN-1 (Bottom View) Internal Connections (Bottom View) 0.5 10 0.5 28.5 Five, 1.3-dia. holes (1.19) 1 2 0.5 15 3.5 7.620.1 0.5 5 4 3 (1.19) 0.1 3.2 7.62 19 (1.5) (No coil polarity) 3.20.1 3.20.1 (1.6) 19 3.2 PCB Mounting Holes Terminal Arrangement/ G6RN-1A (Bottom View) Internal Connections 100.5 (Bottom View) 0.5 28.5 Four, 1.3-dia. holes (1.19) 1 2 0.5 15 3.5 7.620.1 0.5 5 3 (1.19) 0.1 19 5.1 7.62 19 (No coil polarity) 0.1 (1.6) 5.1 (2.8) Approved Standards Precautions Please refer to PCB Relays The rated values approved by each of the safety standards may be different from the performance characteristics individually defined in this catalog. Common Precautions for correct use. UL Recognized (File No. E41515) Number of Number of test Model Coil ratings Contact ratings poles operations G6RN-1 1 5 to 48 VDC 8 A, 250 VAC 85C 6,000 EN/TV Certified (Registration No. 6135) Number of Approved switching Model Coil ratings Contact ratings poles operations G6RN-1 1 5, 6, 12, 24, 48 VDC 8 A, 250 VAC (Resistive) 85C 10,000 G6RN-1A 2 Operate/Release voltage (percentage of rated value) (%) Switching current (A) 4 Durability (x 10 operations) Maximum coil voltage (%)