G6S Surface-mounting Relay Surface-mounting, double-pole signal switching Relay, with terminals jutting out from both sides of the case Long terminals for ideal for soldering and mounting reliability. (Surface mounting terminal models) Space-saving inside-L terminal. (Surface mounting terminal models) Unique terminal construction allowing the terminal temperature to rise easily, ideal for soldering reliability. (Surface mounting terminal models) High dielectric strength (2,000 VAC) and impulse withstand voltage between coil and contacts (2,500 V, 2 10 s: Telcordia requirements). High sensitivity with 140 mW rated power consumption. Ultra-miniature at 9.4 mm (H) 7.5 mm (W) 15 mm (L). Applicable to IRS using heat-resistant material. Standard model conforms to UL/CSA standards. Model with PCB terminals (G6S -2) is added to this series. EN60950 certified type is available. (-Y type) G RoHS Compliant 6 S Model Number Legend Application Examples Telecommunication equipment G6S - - Measurement devices 123 4 Office automation machines 1. Relay Function 3. Terminal Shape Audio-visual products. None : Single-side stable None : PCB terminals U : Single-winding latching F : Outside-L surface mounting terminals K : Double-winding latching G : Inside-L surface mounting terminals 2. Number of poles/ 4. Approved Standards Contact form None : UL/CSA 2: 2-pole/DPDT (2c) Y : EN60950 certified Ordering Information Surface mounting terminal standard models (UL, CSA certified) Relay Function Single-side stable Single-winding latching Double-winding latching Minimum Minimum Enclosure ordering unit packing unit Contact form Model Rated coil voltage Model Rated coil voltage Model Rated coil voltage rating (tape packing) 3 VDC 3 VDC 3 VDC 4.5 VDC 4.5 VDC 4.5 VDC G6S-2F G6SU-2F G6SK-2F 50 pcs/tube 800 pcs/ Fully sealed DPDT (2c) 5 VDC 5 VDC 5 VDC G6S-2G G6SU-2G G6SK-2G (400 pcs/reel) 2 reels 12 VDC 12 VDC 12 VDC 24 VDC 24 VDC 24 VDC Surface mounting terminal standard models (EN60950 certified) Relay Function Single-side stable Minimum Minimum Enclosure ordering unit packing unit Contact form Model Rated coil voltage rating (tape packing) 5 VDC G6S-2F-Y 800 pcs/ 50 pcs/tube Fully sealed DPDT (2c) 12 VDC G6S-2G-Y (400 pcs/reel) 2 reels 24 VDC Note 1. When ordering, add the rated coil voltage to the model number. Example: G6S-2F 3 VDC Rated coil voltage Note 2.When ordering tape packing, add -T to the model number. Be sure since -T is not part of the relay model number, it is not marked on the relay case. 1G6S Surface-mounting Relay PCB Terminal Standard Models (UL, CSA certified) Relay Function Single-side stable Single-winding latching Double-winding latching Minimum Enclosure packing unit rating Contact form Model Rated coil voltage Model Rated coil voltage Model Rated coil voltage 3 VDC 3 VDC 3 VDC 4.5 VDC 4.5 VDC 4.5 VDC Fully sealed DPDT (2c) G6S-2 5 VDC G6SU-2 5 VDC G6SK-2 5 VDC 50 pcs/tube 12 VDC 12 VDC 12 VDC 24 VDC 24 VDC 24 VDC PCB Terminal Standard Models (EN60950 certified) Relay Function Single-side stable Minimum Enclosure packing unit rating Contact form Model Rated coil voltage 5 VDC Note: When ordering, add the rated coil voltage to the model number. Fully sealed DPDT (2c) G6S-2-Y 12 VDC 50 pcs/tube Example: G6S-2 3 VDC Rated coil voltage 24 VDC Ratings Single-side Stable Model (G6S-2, G6S-2F, G6S-2G) Contacts Must operate Must release Max. voltage Item Load Resistive load Item Rated Coil Power voltage (V) voltage (V) (V) current resistance consumption Contact type Bifurcated crossbar Rated voltage (mA) () (mW) % of rated voltage Contact material Ag (Au-Alloy) 3 VDC 46.7 64.3 0.5 A at 125 VAC Rated load G 4.5 VDC 31.0 145 2 A at 30 VDC 200% Approx. 140 6 (at 23C) 5 VDC 28.1 178 Rated carry 75% max. 10% min. 2 A S current 12 VDC 11.7 1,028 Max. switching 170% 250 VAC, 220 VDC 24 VDC 8.3 2,880 Approx. 200 voltage (at 23C) Max. switching Note 1. The rated current and coil resistance are measured at a coil temperature of 23C with a tolerance of 10%. 2 A current 2.Operating characteristics are measured at a coil temperature of 23C. 3.The maximum voltage is the highest voltage that can be imposed on the relay coil. Single-winding Latching Model (G6SU-2, G6SU-2F, G6SU-2G) Must set Must reset Max. voltage Item Rated Coil Power voltage (V) voltage (V) (V) current resistance consumption Rated voltage (mA) () (mW) % of rated voltage 3 VDC 33.3 90 4.5 VDC 22.2 203 Approx. 100 180% 5 VDC 20 250 75% max. 75% max. (at 23C) 12 VDC 8.3 1,440 24 VDC 6.3 1,152 Approx. 150 Note 1. The rated current and coil resistance are measured at a coil temperature of 23C with a tolerance of 10%. 2.Operating characteristics are measured at a coil temperature of 23C. 3.The maximum voltage is the highest voltage that can be imposed on the relay coil. Double-winding Latching Model (G6SK-2, G6SK-2F, G6SK-2G) Must set Must reset Max. voltage Item Rated Coil Power voltage (V) voltage (V) (V) current resistance consumption Rated voltage (mA) () (mW) % of rated voltage 3 VDC 66.6 45 4.5 VDC 44.4 101 170% Approx. 200 (at 23C) 5 VDC 40 125 75% max. 75% max. 12 VDC 16.7 720 140% 24 VDC 12.5 1,920 Approx. 300 (at 23C) Note 1. The rated current and coil resistance are measured at a coil temperature of 23C with a tolerance of 10%. 2.Operating characteristics are measured at a coil temperature of 23C. 3.The maximum voltage is the highest voltage that can be imposed on the relay coil. EN60950 certified Model (G6S-2F-Y, G6S-2G-Y, G6S-2-Y) Must operate Must release Max. voltage Item Rated Coil Power voltage (V) voltage (V) (V) current resistance consumption Rated voltage (mA) () (mW) % of rated voltage 5 VDC 40 125 Approx. 200 170% 12 VDC 16.7 720 75% max. 10% min. (at 23C) 24 VDC 9.6 2,504 Approx. 230 Note 1. The rated current and coil resistance are measured at a coil temperature of 23C with a tolerance of 10%. 2.Operating characteristics are measured at a coil temperature of 23C. 3.The maximum voltage is the highest voltage that can be imposed on the relay coil. 2