Low Signal Relay
G6S
Surface Mount DPDT Relay
High dielectric withstand voltage of 2,000 VAC between coil
and contacts (standard type); 1,500 VAC between contacts
of different polarity.
Meets FCC Part 68 and Telcordia 2.5 kV surge withstand.
Standard models conform to UL/CSA standards. BSI
(EN60950) certified models available (-Y versions)
Low power consumption of 140 mW (Non-latching)
Available in through-hole and SMT terminals.
Tape and reel or tube packaging.
RoHS Compliant.
Ordering Information
Standard Version
.
Model Non-latching
Terminal Single coil latching Dual coil latching
Standard European Version*
Contact form
Gull-wing DPDT G6S-2F G6S-2F-Y G6SU-2F G6SK-2F
Inside L G6S-2G G6S-2G-Y G6SU-2G G6SK-2G
PCB through-hole G6S-2 G6S-2-Y G6SU-2 G6SK-2
* BSI certified for EN60950
Notes: 1. When ordering, add the rated coil voltage to the model number.
Example: G6S-2F DC12
Rated coil voltage
2. When ordering tape packing (surface mount models), add -T to the model number.
Example: G6S-2F-TR DC12
Tape packing
-T is not part of the relay model number. Therefore, it is not marked on the relay case.
3. Dual coil latching models are available with a High-sensitivity coil. (140 mW; 200 mW for DC24)
When ordering High-sensitivity dual coil latching models, add-H to the model number.
Example: G6SK-2G-H-TR DC5
High-sensitivity coil
Model Number Legend
G6S - - - DC
1 2 3 4 5 6
3. Terminal Shape 5. Packaging
1. Relay Function
None: Tube packaging
None: Non-latching None: Through-hole
TR: Tape and reel packaging
U: Single coil latching F: Gull-wing surface mount
(Surface mount models)
K: Dual coil latching G: Inside L surface mount
2. Contact Form 4. Approved Standards
6. Rated Coil Voltage
2: DPDT
None: UL, CSA 3, 4.5, 5, 12, 24 VDC
Y: UL, CSA, BSI (EN60950)
(Standard coil models - 5, 12, 24 VDC )
Low Signal Relay G6S 1Specification
Contact Data
Load Resistive load (cos f=1)
Rated load 0.5 A at 125 VAC
2Aat30VDC
Contact type Bifurcated crossbar
Contact material Ag (Au-Alloy)
Max. carry current 2A
Max. operating voltage 250 VAC, 220 VDC
Max. operating current 2A
Max. switching capacity 62.5 VA, 60 W
Min. permissible load 10 A, 10 mVDC
-6
Note: P level: =0.1x10 /operation
60
This value was measured at a switching frequency of 120 operations/min and the criterion of contact resistance is 50 . This value may vary
depending on the operating environment. Always double-check relay suitability under actual operating conditions.
Coil Data
G6S - Standard Non-latching (G6S-2F, G6S-2G, G6S-2)
Pick-up Dropout Maximum
Rated Rated Coil
voltage voltage voltage
voltage current resistance Power consumption (mW)
(VDC) (mA) ()
% of rated voltage
3 46.7 64.3 75% max. 10% min. 200% max.@ 23C Approx. 140
4.5 31.0 145
5 28.1 178
12 11.7 1,028
24 8.3 2,880 170% max.@ 23C Approx. 200
G6SU - Standard Single Coil Latching (G6SU-2F, G6SU-2G, G6SU-2)
Coil Inductance (H) Set pick-up Reset pick-up
Rated Rated Coil Power
Maximum volt-
(ref. value) voltage voltage
voltage current resistance consumption
age
(VDC) (mA) () (mW)
Armature OFF Armature ON % of rated voltage
3 33.3 90 0.108 0.069 75% max. 75% max. 180% max. Approx. 100
@23C
4.5 22.2 203 0.27 0.14
5 20.0 250 0.36 0.18
12 8.3 1,440 2.12 1.14
24 6.3 3,840 5.80 3.79 Approx. 150
G6SK - Standard Dual Coil Latching (G6SK-2F, G6SK-2G, G6SK-2)
Coil Inductance (H)
Set Reset
(ref. value)
pick-up pick-up
Rated Rated Coil Power
Maximum
voltage voltage
voltage current resistance Set Reset consumption
voltage
(VDC) (mA) () (mW)
Armature Armature Armature Armature
% of rated voltage
OFF ON OFF ON
3 66.6 45 0.045 0.035 0.032 0.045 75% max. 75% max. 170% max. Approx. 200
@23C
4.5 44.4 101 0.12 0.074 0.082 0.14
5 40 125 0.14 0.088 0.098 0.16
12 16.7 720 0.60 0.41 0.46 0.54
24 12.5 1,920 1.98 1.23 1.34 2.23 140% max. Approx. 300
@23C
G6S - European Version (EN60950 certified), Non-latching (G6S-2F-Y, G6S-2G-Y, G6S-2-Y)
Rated Rated Coil Pick-up Dropout Maximum Power consumption (mW)
voltage current resistance voltage voltage voltage
(VDC) (mA) ()
% of rated voltage
5 40.0 125 75% max. 10% min. 170% max.@ 23C Approx. 200
12 16.7 720
24 9.6 2,504 Approx. 230
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23C with a tolerance of 10%.
2. The operating characteristics are measured at a coil temperature of 23C.
3. Pick-up voltage will vary with temperature.
4. The maximum voltage is the highest voltage that can be imposed on the relay coil.
2 Low Signal Relay G6S