G6Z Surface-mounting High-frequency Relay Surface-mounting, 3-GHz-Band, Miniature, SPDT, High-frequency Relay Superior high-frequency characteristics, such as an isolation of 30 dB min., insertion loss of 0.5 dB max., and V.SWR of 1.5 max. at 2.6 GHz. Surface-mounting terminals and superior high frequency characteristics combined using semi triplate strip transmission lines. Miniature dimensions of 20 8.6 8.9 mm (L W H). Choose from a lineup that includes single-winding latching models (200 mW), double-winding latching models (360 mW), and models with a reverse contact arrangement. Series includes models with an E-shape terminal structure (same as existing models), and models with a Y-shape terminal structure, allowing greater freedom with PCB design. Models with 75- impedance and models with 50- impedance are available. RoHS Compliant G 6 Model Number Legend Application Examples Z These Relays can be used for switching signals in media G6Z - - equipment. 1234 56 Wire communications: Cable TV (STB and broadcasting infrastructure), cable modems, and 1. Relay Function 4. Terminal arrangement VRS (video response systems) None: Single-side stable None: Y-shape terminal Wireless communications:Transceivers, ham radios, car U: Single-winding structure telephones, ETC, ITS, high-level latching E: E-shape terminal TV, satellite broadcasting, text K: Double-winding structure multiplex broadcasting, pay TV, latching 5. Characteristic Impedance mobile phone stations, TV 2. Contact Form None: 75 broadcasting facilities, and 1: SPDT (1c) A: 50 community antenna systems 3. Terminal Shape 6. Contact Arrangement Public equipment: TVs, TV games, satellite radio units, F: Surface-mounting None: Standard contact car navigation systems terminals arrangement Industrial equipment: Measuring equipment, test P: PCB terminals R: Reverse contact equipment, and multiplex arrangement transmission devices Ordering Information Standard Models with PCB Terminals Enclosure Contact Terminal Characteristic Minmum packing Relay Function Model Rated coil voltage rating form arrangement impedance unit 75 G6Z-1PE 3, 4.5, 5, 9, 12, 24 VDC E-shape 50 G6Z-1PE-A 3, 4.5, 5, 9, 12, 24 VDC Singleside stable 75 G6Z-1P 3, 4.5, 5, 9, 12, 24 VDC Y-shape 50 G6Z-1P-A 3, 4.5, 5, 9, 12, 24 VDC 75 G6ZU-1PE E-shape 50 G6ZU-1PE-A Singlewinding SPDT Fully sealed 3, 4.5, 5, 9, 12, 24 VDC 25 pcs/tube latching (1c) 75 G6ZU-1P Y-shape 50 G6ZU-1P-A 75 G6ZK-1PE E-shape 50 G6ZK-1PE-A Doublewinding 3, 4.5, 5, 9, 12, 24 VDC latching 75 G6ZK-1P Y-shape 50 G6ZK-1P-A Note. Please add the coil rated voltage (V) to the model number when ordering. Example: G6Z-1PE DC3 In addition, the delivered product and its package will be marked with voltage specification as VD. 1G6Z Surface-mounting High-frequency Relay Standard Models with Surface-mounting Terminals Minimum Enclosure Contact Terminal Characteristic Rated coil Minmum Relay Function Model ordering unit rating form arrangement impedance voltage packing unit (Tape packing) 75 G6Z-1FE E-shape 50 G6Z-1FE-A 3, 4.5, 5, 9, 12 Singleside stable and 24 VDC 75 G6Z-1F Y-shape 50 G6Z-1F-A 75 G6ZU-1FE E-shape 25 pcs/tube 50 G6ZU-1FE-A Singlewinding SPDT 3, 4.5, 5, 9, 12 Fully sealed (300 pcs/ 300 pcs/reel latching (1c) and 24 VDC 75 G6ZU-1F reel) Y-shape 50 G6ZU-1F-A 75 G6ZK-1FE E-shape 50 G6ZK-1FE-A Doublewinding 3, 4.5, 5, 9, 12 latching and 24 VDC 75 G6ZK-1F Y-shape 50 G6ZK-1F-A Note 1. Please add the coil rated voltage (V) to the model number when ordering. Example: G6Z-1PE DC3 In addition, the delivered product and its package will be marked with voltage specification as VD. Note 2. When ordering Relays in tape packing (surface mounting terminal models), add-T to the end of the model number. This specification, however, is not part of the relay model number, so it is not marked on the relay case. (If-T is not added to the end of the model number, the Relays will be provided in tube packing.) G Note 3. Consult your OMRON representative for reverse contact models. 6 Z Ratings Coil: Single-side Stable Models (G6E-2P(E), G6Z-1F(E)) Must operate voltage Must release voltage Maximum voltage Rated current Coil resistance Power consumption (V) (V) (V) (mA) () (mW) Raged voltage % of rated voltage 3 VDC 66.7 45 4.5 VDC 44.4 101 5 VDC 40.0 125 75% max. 10% min. 150% Approx. 200 9 VDC 22.2 405 12 VDC 16.7 720 24 VDC 8.3 2,880 Coil: Single-winding Latching Models (G6ZU-1P(E), G6ZU-1F(E)) Must set voltage Must reset voltage Maximum voltage Rated current Coil resistance Power consumption (V) (V) (V) (mA) () (mW) Raged voltage % of rated voltage 3 VDC 66.7 45 4.5 VDC 44.4 101 5 VDC 40.0 125 75% max. 75% max. 150% Approx. 200 9 VDC 22.2 405 12 VDC 16.7 720 24 VDC 8.3 2,880 Coil: Double-winding Latching Models (G6ZK-1P(E), G6ZK-1F(E)) Must set voltage Must reset voltage Maximum voltage Rated current Coil resistance Power consumption (V) (V) (V) (mA) () (mW) Raged voltage % of rated voltage 3 VDC 120 25 4.5 VDC 80 56 5 VDC 72 69 75% max. 75% max. 150% Approx. 360 9 VDC 40 225 12 VDC 30 400 24 VDC 15 1,600 Note 1. The rated current and coil resistance are measured at a coil temperature of 23C with a tolerance of 10%. Note 2. The operating characteristics are measured at a coil temperature of 23C. Note 3. The maximum voltage is the highest voltage that can be imposed on the Relay coil instantaneously. Note 4. The voltage measurements for operate/release and set/reset are the values obtained for instantaneous changes in the voltage (rectangular wave). 2