Power PCB Relay G8PT Up to 30 A switching capacity in compact package. Available with quick-connect contact terminals for easy load connecting with either QC or PCB coil terminals. UL Class F coil insulation standard Minimum 6 kV Impulse Surge Withstand. Ideal for home and industrial appliances, HVAC and many other applications. UL recognized / CSA certified. VDE approved. RoHS Compliant Ordering Information To Order: Select the part number and add the desired coil voltage rating, (e.g., G8P-1A4P-DC12). Mounting type Contact form Construction Model PCB SPST-NO Open frame G8P-1AP Sealed with ventable nib* G8P-1A4P SPDT Open frame G8P-1CP Sealed with ventable nib* G8P-1C4P PCB & Quick Connect SPST-NO Open frame G8P-1ATP load terminals Sealed with ventable nib* G8P-1A4TP SPDT Open frame G8P-1CTP Sealed with ventable nib* G8P-1C4TP Flange mount Quick SPST-NO Vented G8P-1A2T-F Connect terminals SPDT Vented G8P-1C2T-F Note: Load terminals are .250 Quick Connect. Coil terminals on Flange Mount versions are .187 Quick Connect. * Sealed and vented optional. Specifications Contact Data Type SPST-NO SPDT Rated load 30 A 250 VAC, 20 A 28 VDC 20/10 A* at 250 VAC, 20/10 A at 28 VDC Contact material Ag-Alloy Carry current 30 A max. 20/10 A* Max. operating voltage 250 VAC, 28 VDC Max. operating current AC 30 A, DC 20 A AC 20/10 A, DC 20/10 A* Max. switching capacity 7,500 VA, 560 W 5,000/2,500 VA, 560/280 W* Min. permissible load 500 mA 5 VDC (See note 1), 100 mA 5 VDC (See note 2) * NO contact/NC contact Note: 1. Applicable for G8P-1A4TP, G8P-1CP, G8P-1C4P, G8P-1C4TP and G8P-1C2T-F versions. 2. Applicable for G8P-1AP, G8P-1A4P, G8P-1ATP and G8P-1CTP versions. Power PCB Relay G8PT 247 Coil Data Rated Rated Coil Pick-up Dropout Maximum Power voltage current resistance voltage voltage voltage consumption (VDC) (mA) () (mW) % of rated voltage 5 185 27 75% max. 10% min. 120% max. Approx. 900 993 97 12 77 155 24 36 660 48 19 2,480 110 9 12,400 Note: The rated current and coil resistance are measured at a coil temperature of 23C (73F) with tolerances of 10%. Characteristics Contact resistance 100 m max. (measured with 5 VDC, 1 A) Operate time 15 ms. max. Release time 10 ms. max. Insulation resistance 100 M min. (at 500 VDC) Dielectric strength 2,500 VAC, 50/60 Hz for 1 minute (coil to contacts), 1,500 VAC, 50/60 Hz for 1 minute (between contacts) Impulse surge withstand 6,000 V between coil to contacts (1.2 s/50 s & 100 kHz ring wave per IEC 1000-4-12) Vibration Mechanical durability 10 to 55 Hz, 1.65 mm (0.06 in) double amplitude for 2 hours Malfunction durability 10 to 55 Hz, 1.65 mm (0.06 in) double amplitude for 5 minutes 2 Shock Mechanical durability 1,000 m/s (approx. 100 G) 2 Malfunction durability 100 m/s (approx. 10 G) Ambient temperature -55 to 105C, cold coil condition (with no icing) -55 to 85C, hot coil condition (hot start) (with no icing) Humidity 5% to 85% RH Service life Mechanical 10 million operations minimum Electrical 100,000 operations, 360 ops/hr, at rated load (minimum) Note: 1. Data shown are of initial value. Operate and release times excluding bounce. 2. Please vent sealed relays after processing in order to achieve rated electrical service life, by removing the vent nib. Characteristic Data Maximum switching capacity SPDT SPST-NO Rated operating voltage (V) Rated operating voltage (V) 248 Power PCB Relay G8PT Rated operating current (A) Rated operating current (A)