Power PCB Relay G8P Up to 30 A switching capacity in compact package Available with quick-connect terminals for easy load connecting UL Class F coil insulation standard Complies with UL 873 and UL 508 column A spacings up to 300 V Minimum 6kV Impulse Surge Withstand Ideal for home and industrial appliances, HVAC (heating, ventilating, and air condi- tioning), and many other applications UL/CSA approvals, VDE pending Ordering Information To Order: Select the part number and add the desired coil voltage rating, (e.g., G8P-1A4P-DC12). Mounting type Contact form Construction Part number PCB SPST-NO Open frame G8P-1AP Sealed with ventable nib G8P-1A4P SPDT Open frame G8P-1CP Sealed with ventable nib G8P-1C4P PCB & Quick Connect SPST-NO Open frame G8P-1ATP load terminals Sealed with ventable nib G8P-1A4TP SPDT Open frame G8P-1CTP Sealed with ventable nib G8P-1C4TP Flange mount Quick SPST-NO Vented G8P-1A2T-F Connect terminals SPDT Vented G8P-1C2T-F Note: Load terminals are .250 Quick Connect. Coil terminals on Flange Mount versions are .187 Quick Connect. Specifications CONTACT DATA Type SPST-NO SPDT Rated load 30 A at 250 VAC, 20 A at 28 VDC 20/10 A* at 250 VAC, 20/10 A at 28 VDC Contact material AgCdO Carry current 30 A 20/10 A* Max. operating voltage 250 VAC, 28 VDC Max. operating current AC 30 A, DC 20 A AC 20/10 A, DC 20/10 A* Max. switching capacity 7,500 VA, 560 W 5,000/2,500 VA, 560/280 W* Min. permissible load DC 5 V, 500 mA * NO contact/NC contactG8P G8P COIL DATA Rated Rated Coil Pick-up Dropout Maximum Power voltage current resistance voltage voltage voltage consumption (VDC) (mA) ( ) (mW) % of rated voltage 5 185 27 75% max. 10% min. 120% max. Approx. 900 993 97 12 77 155 24 36 660 48 19 2480 110 9 12400 Note: The rated current and coil resistance are measured at a coil temperature of 23C (73F) with tolerances of 10%. CHARACTERISTICS Contact resistance 100 m max. (measured with 5 VDC, 1 A) Operate time 15 ms max. Release time 10 ms max. Insulation resistance 10 M min. (at 500 VDC) Dielectric strength 2,500 VAC, 50/60 Hz for 1 minute (coil to contacts), 1,500 VAC, 50/60 Hz for 1 minute (between contacts) Impulse surge withstand 6,000 V between coil to contacts (1.2 s/50 s & 100 kHz ring wave per IEC 1000-4-12) Vibration Mechanical durability 10 to 55 Hz, 1.65 mm (0.06 in) double amplitude for 2 hours Malfunction durability 10 to 55 Hz, 1.65 mm (0.06 in) double amplitude for 5 minutes 2 Shock Mechanical durability 1,000 m/s (approx. 100 G) 2 Malfunction durability 100 m/s (approx. 10 G) Ambient temperature -55 to 105C (-67 to 221F) Humidity 45% to 85% RH Service life Mechanical 10 million operations minimum Electrical 100,000 operations at rated load (minimum) Note: Data shown are of initial value. Operate and release times excluding bounce. CHARACTERISTIC DATA Maximum switching capacity SPST-NO SPDT Rated operating voltage (V) Rated operating voltage (V) 2 Rated operating current (A) Rated operating current (A)