Hybrid Power Relay G9H CSM G9H DS E 6 1 Hybridization of a Magnetic Relay and an SSR Achieves 10-A Switching for 10 Million Operations. UL/CSA certified (-US models). Using a triac to open and close the circuit reduces chattering and arching, thereby increasing the electrical durability to 10 million operations. Relays contacts for power ON and 10-A switching with high- capacity are provided in a compact body without the need of radiators. Plus, there is almost no effect on heat generation or ambient temperature. Operation indicators to easily check operation. For the most recent information on models that have been certified for Built-in temperature fuse prevents internal burning due to safety standards, refer to your OMRON website. triac or relay malfunctions. Socket-type Relays the same size as the 1-pole and 2-pole LY Relays. Refer to Safety Precautions for All Solid State Relays. Ordering Information List of Model Isolation method Zero cross function Operation indicator Applicable output load Rated input voltage Model (See note.) Relay No Yes 5 A 5 VDC G9H-205S DC5 100 to 240 VAC G9H-205S-US DC5 12 VDC G9H-205S DC12 G9H-205S-US DC12 24 VDC G9H-205S DC24 G9H-205S-US DC24 10 A 5 VDC G9H-210S DC5 100 to 240 VAC G9H-210S-US DC5 12 VDC G9H-210S DC12 G9H-210S-US DC12 24 VDC G9H-210S DC24 G9H-210S-US DC24 Note: 1. The actual product is labeled250 VAC 2. For information on products that are certified for international standards, consult your OMRON sales representatives Accessories (Order Separately) Connecting Socket Mounting Plate Model Minimum quantity packaged (units) PYP-1 10 PYP-18 1 Note: Order the models above in increments of the minimum quantity packaged. 1G9H Specifications Ratings Input Rated voltage Item Operating voltage Coil resistance Must operate voltage Must release voltage Power consumption DC 5 V 4 to 6 VDC 104 4 VDC max. 0.5 VDC min. Approx. 240 mW 12 V 9.6 to 14.4 VDC 600 9.6 VDC max. 1.2 VDC min. 24 V 19.2 to 28. 8 VDC 2,400 19.2 VDC max. 2.4 VDC min. Note: 1. The coil resistance is measured at a coil temperature of 23C with a tolerance of 10%. 2. Performance characteristic data are measured at a coil temperature of 23C. Output Item Applicable load Model Rated load voltage Load voltage range Load current (See note.) Inrush current resistance G9H-205S 100 to 240 VAC 75 to 264 VAC 50 mA to 5 A (at 55C) 80 A (60 Hz, 1 cycle) G9H-210S 50 mA to 10 A (at 55C) 170 A (60 Hz, 1 cycle) Note: The load current depends on the ambient temperature. For details, refer to Load Current vs. Ambient Temperature in Engineering Data. Characteristics Item Model G9H-205S G9H-210S Operate time 10 ms max. Release time 1/2 cycle max. + 10 ms Output ON voltage drop 1.6 V max. (RMS) (at 5 A) 1.6 V max. (RMS) (at 10 A) Leakage current 5 mA max. at 250 VAC Inrush current resistance 80 A 170 A Temperature rise 50C max. (rated voltage applied using resistance method) Insulation resistance 100 M min. (at 500 VDC) Dielectric strength 2,000 VAC 50/60 Hz 1 min Vibration resistance Destruction 10 to 55 to 10 Hz, 1-mm single amplitude (2-mm double amplitude) Malfunction 10 to 45 to 10 Hz, 1-mm single amplitude (2-mm double amplitude) 2 Shock resistance (See note.) Destruction 1,000 m/s 2 Malfunction 100 m/s Life expectancy Mechanical 10 million operations min. (switching frequency: 18,000 operations/hour) Electrical 10 million operations min. (resistive load and switching frequency: 18,000 operations/hour) Storage temperature 25 to 70C (with no icing or condensation) Ambient operating temperature 25 to 60C (with no icing or condensation) Ambient operating humidity 35% to 85% Weight Approx. 25 g Note: Value when excited. Connection Layout LED X1 X2 Input C Temperature Varistor Output fuseRR R 2 Coil Triac Load