Safety Relay Unit G9SB CSM G9SB DS E 4 1 Ultra Slim Safety Relay Unit Models of width 17.5 mm available with 2 or 3 poles. Models of width 22.5 mm with 3 poles also available. Conforms to EN standards. (TV approval) DIN track mounting possible. Be sure to read the Safety Precautions on page 8. Model Number Structure Note: Please see Ordering Information below for the actual models that can be ordered. Model Number Legend G9SB- - 1 2 3 4 5 6 1. Function 5. Input Configuration None: Emergency stop None: 1-channel or 2-channel input possible 2. Contact Configuration (Safety Output) 0: None (direct breaking) 2: DPST-NO 2: 2-channel input 3: 3PST-NO 6. Miscellaneous 3. Contact Configuration (OFF-delay Output) A: Auto-reset, inverse input 0: None B: Auto-reset, + common input 4. Contact Configuration (Auxiliary Output) C: Manual reset, inverse input 0: None D: Manual reset, + common input 1: SPST-NC Ordering Information Auxiliary Main contacts Number of input channels Reset mode Input type Rated voltage Model contact 2 channels Inverse G9SB-2002-A Auto-reset 1 channel or 2 channels + common G9SB-200-B DPST-NO None 24 VAC/VDC 2 channels Inverse G9SB-2002-C Manual reset 1 channel or 2 channels + common G9SB-200-D None --- 24 VDC G9SB-3010 * (direct breaking) Auto-reset 2 channels Inverse G9SB-3012-A 3PST-NO SPST-NC 1 channel or 2 channels + common G9SB-301-B 24 VAC/VDC 2 channels Inverse G9SB-3012-C Manual reset 1 channel or 2 channels + common G9SB-301-D Note: 1. Relays with inverse inputs are used mainly when inputting signals from two mechanical switches. 2. Relays with positive commons are used mainly when inputting signals from a safety sensor or from one mechanical switch. * The G9SB-3010 can be applied to Safety Category 3 of the EN954-1 if double breaking is used. 1G9SB Specifications Ratings Power Input Item Model G9SB-200 - G9SB-3010 G9SB-301 - 24 VAC/VDC: 24 VAC, 50/60 Hz, or 24VDC Power supply voltage 24 VDC: 24 VDC Operating voltage 85% to 110% of rated power supply voltage range Power consumption 1.6 VA/1.4 W max. 1.7 W max. 2.0 VA/1.7 W max. Inputs Item Model G9SB-200 - G9SB-3010 G9SB-301 - Input current 25 mA max. 60 mA max. * 30 mA max. * Indicates the current between terminals A1 and A2. Contacts Model G9SB-200 - G9SB-3010 G9SB-301 - Item Load Resistive load 250 VAC, 5 A Rated load 30 VDC, 5 A Rated carry current 5 A Characteristics Item Model G9SB-200 - G9SB-3010 G9SB-301 - Contact resistance *1 100 m Operating time *2 30 ms max. Response time *3 10 ms max. Insulation resistance *4 100 M min. (at 500 VDC) Between different outputs Between inputs Dielectric strength 2,500 VAC, 50/60 Hz for 1 min and outputs Between power inputs and outputs Vibration resistance 10 to 55 to 10 Hz, 0.375-mm single amplitude (0.75-mm double amplitude) 2 Destruction 300 m/s Shock resistance 2 Malfunction 100 m/s Mechanical 5,000,000 operations min. (at approx. 7,200 operations/hr) Durability *5 Electrical 100,000 operations min. (at approx. 1,800 operations/hr) Failure rate (P level) (reference value) 5 VDC, 1 mA Ambient operating temperature 25 to 55C (with no icing or condensation) Ambient operating humidity 35% to 85% Terminal tightening torque 0.5 Nm Weight Approx. 115 g Approx. 135 g Approx. 120 g *1. The contact resistance was measured with 1 A at 5 VDC using the voltage-drop method. *2. Not including bounce time. *3. The response time is the time it takes for the main contact to open after the input is turned OFF. Includes bounce time. *4. The insulation resistance was measured with 500 VDC at the same places that the dielectric strength was checked. *5. The durability is for an ambient temperature of 15 to 35C and an ambient humidity of 25% to 75%. 2