Analog Output Module GT1-DA Analog Output Modules Compatible with MULTIPLE I/O TERMINAL Output block incorporates connectors that can be easily mounted or dismounted. 4 inputs High resolution of 1/6,000. High conversion speed of 4 ms/4 points. Dimensions of connector model: 110 60 65 (W H D) Dimensions of terminal block model: 80 80 65 (W H D) DIN track mounting Ordering Information I/O classification I/O points Terminal Power supply I/O specification Model voltage Analog output 4 Connector 24 VDC 0 to 5 V, 1 to 5 V, GT1-DA04MX 0 to 10 V, --10 to 10 V Terminal block 0 to 5 V, 1 to 5 V, GT1-DA04 0 to 10 V, --10 to 10 V, 4 to 20 mA Note: A communications cable, GCN1--004, is included with each module. Specifications Output Item Voltage output Current output Output points 4 Output type 0 to 5 V, 1 to 5 V, 0 to 10 V, --10 to 4 to 20 mA 10 V Output permissible load resistance 5 kW min. 600 W max. Output impedance 0.5 W max. --- Resolution 1/6,000 (full scale) OOvveerraallll aaccccuurraaccyy 25C 0.4% full scale --10C to 55C 0.8% full scale Conversion speed 4 ms/4 points DA output data Binary data --10- to 10-V range: F448 to 0BB8 full scale Other signal ranges: 0000 to 1770 full scale Insulation method Transistor or photocoupler insulation between outputs and power lines. 59GT1-DA GT1-DA Characteristics I/O power supply voltage 20.4 to 26.4 VDC (24 VDC +10%/--15%) CCuurrrreenntt ccoonnssuummppttiioonn I/O Module Interface Internal circuitry power supply 50 mA max. GT1-DA04MX: 100 mA max. GT1-DA04: 150 mA max. Noise immunity 1,500 V (p-p) with a pulse width of 0.1 to 1 ms 2 Vibration resistance 10 to 150 Hz, 1.0-mm double amplitude or 70 m/s 2 Shock resistance 200 m/s Dielectric strength 500 VAC Mounting method 35-mm DIN track mounting Mounting strength No damage when 100 N pull load was applied in all directions (10 N min. in the DIN track direction) Terminal strength No damage when 100 N pull load was applied Ambient temperature Operating: --10C to 55C Storage: --25C to 65C Ambient humidity Operating: 25% to 85% RH (with no condensation) Connectors Type Model Remarks Molex connector IDC (Use Press-fit tool.) Housing GCN1--MX25--B* (25 piece bag from OMRON) 22 AWG SSoollddeerrlleessss tteerrmmiinnaall Housing 50--57--9403 CChhaaiinn tteerrmmiinnaall 16--02--0069 24 to 30 AWG 16--02--0086 22 to 24 AWG Loose terminal 16--02--0096 24 to 30 AWG Press-fit tool 11--01--0209 (See note.) Note: Contact your OMRON representatives for the above connectors. * Stocked by OMRON. Nomenclature TS indicator (status indicator of I/O Module interface) GT1-DA04MX Indicates the status of the I/O Module interface. PWR indicator (internal power supply indicator) The green indicator is lit if internal circuitry power supply is provided. U.ERR indicator (Unit error indicator) The red indicator is lit if the Module malfunctions or no internal circuitry power supply is provided. Connectors for I/O Module interface Connects to the Communications Modules or other I/O Modules. Connect the Communications Module to connector 1. When connecting I/O Modules to the GT1-AD, connector 2 of the GT1-AD must be connected to Specification setting switch +24 VDC --24 VDC connector 1 of the first I/O Module and connector 2 of the first I/O Module must be connected to connector 1 Internal power of the next I/O Module. Connect all the I/O Modules in supply terminals the same way. Supply 24 VDC +10%/--15% to these ter- minals for the operation of the Module. Be sure to connect the end connector to connector 2 of the last I/O Module. TS Indicator (Status Indicator of I/O Module Interface) Voltage input COM Current input Green indicator lit The Module is normal. Analog input connectors 0 to 7 These connectors are for analog output use. Each Red indicator lit The I/O Module interface has an error. output connector has three pins (i.e., a voltage, COM, and NC pins from left to right) Not lit No power is supplied to the Module or the Module is being initialized. 60