Solid-state Timer H3JA Economical, Compact, Plug-in Timer Time limit, ON-delay, operation with automatic resetting. DIN size (36 x 36 mm), fits standard 8-pin sockets. Wide choice of supply voltages: 24, 100 to 120, 200 to 240 VAC, 12, 24 VDC. Dual LED indication for power and output status. Large transparent setting knob. Setting error rating almost matches that of a 48 x 48 timer. Conforms to UL and CSA, and meets CE marking requirements. Ordering Information Stock Note: Shaded models are normally stocked. Operation/resetting Time-limit contact Mounting method Rated time Model system Time-limit operation/ SPDT Surface mounting, flush 1 s, 3 s, 5 s, 10 s, 30 s, 60 s, H3JA-8A self-resetting mounting, and DIN track 3 min, 5 min, 10 min, 30 mounting min, 60 min, 3 hrs DPDT 1 s, 3 s, 5 s, 10 s, 30 s, 60 s, H3JA-8C 3 min, 5 min, 10 min, 30 min, 60 min, 3 hrs Note: Specify the model number, supply voltage, and rated time when ordering. Ex. H3JA-8A 100 to 120 VAC 1 s Rated time Supply voltage Solid-state Timer H3JA 1 Accessories (Order Separately) Stock Note: Shaded models are normally stocked. Name/specifications Model Flush mounting adapter Y92F-31 Mounting track 50 cm (l) x 7.3 mm (t) PFP-50N 1 m (l) x 7.3 mm (t) PFP-100N 1 m (l) x 16 mm (t) PFP-100N2 End plate PFP-M Spacer PFP-S Track mounting/ 8-pin PF085A Front connecting socket Back connecting socket 8-pin P3G-08 8-pin, finger safe type P3G-08 with Y92A-48G (see note 1) Hold-down clip (see note 2) For PF085A Socket Y92H-6 Note: 1. Y92A-48G is a finger safe terminal cover which is attached to the P3G-08 Socket. 2. Hold-down Clips are sold in sets of two. Specifications Time Ranges Rated time Time range Rated time Time range 1 s 0.1 to 1 s 3 min 0.3 to 3 min 3 s 0.3 to 3 s 5 min 0.5 to 5 min 5 s 0.5 to 5 s 10 min 1 to 10 min 10 s 1 to 10 s 30 min 3 to 30 min 30 s 3 to 30 s 60 min 6 to 60 min 60 s 6 to 60 s 3 hrs 0.3 to 3 hrs Ratings Rated supply voltage 24, 100 to 120 or 200 to 240 VAC (50/60 Hz) 24 VDC 12 VDC (only available on H3JA-8A model) Operating voltage range 85% to 110% of rated supply voltage Power consumption H3JA-8A 100 to 120 VAC: Approx. 3 VA (1.3 W) at 120 VAC 200 to 240 VAC: Approx. 5 VA (1.5 W) at 240 VAC 24 VAC: Approx. 1.2 VA (0.9 W) at 24 VAC 24 VDC: Approx. 0.8 W at 24 VDC H3JA-8C 100 to 120 VAC: Approx. 3 VA (1.1 W) at 120 VAC 200 to 240 VAC: Approx. 5 VA (1.3 W) at 240 VAC 24 VAC: Approx. 1.3 VA (1 W) at 24 VAC 24 VDC: Approx. 0.9 W at 24 VDC Control outputs H3JA-8A: 7 A at 250 VAC, resistive load H3JA-8C: 5 A at 250 VAC, resistive load 2 Solid-state Timer H3JA