New Product Solid-State Timer H3RN- -B Compact, Multi-function Timers Fit G2R Relay Footprint The Push-In Plus Terminal Block Socket-compatible H3RN--B Timers in a black design join the Compact, Multi-function H3RN Timers. Standard multiple time ranges and multiple operating modes. Timers plug into P2RF-PU Sockets with Push-In Plus Terminals reducing wiring time by 60 percent UL listed.* Conforms to CSA and CE Marking. * When used in combination with a Push-In Plus Terminal Block Socket (P2RF- -PU). For the most recent information on models that have been certified for safety standards, refer to your Refer to Safety Precautions on page 6. OMRON website. Model Number Structure Model Number Legend H3RN- -B 1 2 1.Output 2.Time Range 1: SPDT None: Short-time range (0.1 s to 10 min) 2: DPST-NO 1: Long-time range (0.1 min to 10 hrs) Ordering Information List of Models Short-time range model Long-time range model Supply voltage Time-limit contact (0.1 s to 10 min) (0.1 min to 10 h) SPDT H3RN-1-B H3RN-11-B 24 VAC 12, 24 VDC DPST-NO H3RN-2-B H3RN-21-B Note: Specify both the model number and supply voltage when ordering. Example: H3RN-1-B 24 VAC Supply voltage Accessories (Order Separately) Socket Timer Track mounting/Front connecting socket H3RN-1-B/-11-B P2RF-05-PU H3RN-2-B/-21-B P2RF-08-PU 1H3RN- -B Specifications Ratings Item H3RN-1-B/H3RN-2-B H3RN-11-B/H3RN-21-B 0.1 s to 10 min (1 s, 10 s, 1 min, or 10 min max. 0.1 min to 10 h (1 min, 10 min, 1 h, or 10 hrs max. Time ranges selectable) selectable) Rated supply voltage *2 24 VAC (50/60 Hz) 12, 24 VDC Pin type Plug-in Operating mode ON-delay, interval, flicker OFF-start, or flicker-ON start selectable by DIP switch Operating voltage range 85% to 110% of rated supply voltage (12 VDC: 90% to 110% of rated supply voltage) *1 Reset voltage 10% max. of rated supply voltage 24 VAC: Relay ON: approx. 0.8 VA Power consumption 12 VDC: Relay ON: approx. 0.5 W 24 VDC: Relay ON: approx. 0.4 W 3 A at 250 VAC, resistive load (cos = 1) (G6B-2 14P-FD-US used (Contact materials : AgSnIn)) Control outputs The minimum applicable load is 10 mA at 5 VDC (P reference value). *1. When using the H3RN in any place where the ambient temperature is more than 50C, supply 90% to 110% of the rated voltages (12 VDC: 95% to 110% of the rated voltage). *2. Refer to Safety Precautions for All Times when combining the Timer with an AC 2-wire proximity sensor. Characteristics Item H3RN-1-B/H3RN-2-B H3RN-11-B/H3RN-21-B Accuracy of operating time 1% FS max. (1 s range: 1%10 ms max.) Setting error 15%50 ms FS max. Min. power-opening time:12, 24 VDC: 0.1 s max. (including halfway reset) Reset time 24 VAC: 0.5 s max. (including halfway reset) Influence of voltage 2% FS max. Influence of temperature 2% FS max. Insulation resistance 100 M min. (at 500 VDC) 2,000 VAC, 50/60 Hz for 1 min (between operating circuit and control output, or contacts of different Dielectric strength poles) 1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts) Destruction: 10 to 55 Hz, 0.75-mm single amplitude for 1 h each in 3 directions Vibration resistance Malfunction: 10 to 55 Hz, 0.5-mm single amplitude for 10 min each in 3 directions 2 Destruction: 980 m/s *1 Shock resistance 2 Malfunction: 100 m/s Operating: 10C to 55C (with no icing) Ambient temperature Storage: 25C to 65C (with no icing) Ambient humidity Operating: 35% to 85% Mechanical: 10,000,000 operations min. (under no load at 1,800 operations/h) Life expectancy Electrical: 100,000 operations min. (3 A at 250 VAC, resistive load at 1,800 operations/h) Impulse withstand voltage Between power terminals: 1 kV Noise immunity 1.5 kV, square-wave noise by noise simulator (pulse width: 100 ns/1 s, 1-ns rise) Destruction: 8 kV Static immunity Malfunction: 4 kV Degree of protection IP40 (Terminal screw sections are excluded.) Weight Approx. 18 g (EMI) EN 61812-1 Emission Enclosure: EN 55011 Group 1 class A Emission AC Mains: EN 55011 Group 1 class A (EMS) EN 61812-1 Immunity ESD: IEC 61000-4-2 EMC Immunity RF-interference: IEC 61000-4-3 Immunity Burst: IEC 61000-4-4 Immunity Surge: IEC 51000-4-5 Immunity Conducted Disturbance: IEC 61000-4-6 Immunity Voltage Dip/Interruption: IEC 61000-4-11 cULus (or cURus): UL 508/CSA C22.2 No.14 *2, CSA C22.2 No.14 Approved standards Conforms to EN 61812-1, IEC 60664-1 4 kV/2. *1. The destructive shock resistance test was performed on a standalone Timer. *2. cULus (Listing): Applicable when an OMRON P2RF- -PU Socket is used. cURus (Recognition): Applicable when any other socket is used. 2