Solid-state Timer H3YN Miniature Timer with Multiple Time Ranges and Multiple Operating Modes Minimizes stock. Pin configuration compatible with MY Power Relay. Standard multiple operating modes and multiple time ranges. Conforms to VDE 0435/P2021 and approved by UL and CSA. Conforms to EMC standards. RC Ordering Information Supply voltage Time-limit contact Short-time range model Long-time range model (0.1 s to 10 min) (0.1 min to 10 h) 24, 100 to 120, 200 to 230 VAC DPDT H3YN-2 H3YN-21 1212, 24, 48, 100 to 124 48 100 to 11010, 4PDT H3YN-4 H3YN-41 125 VDC 24 VDC 4PDT (Twin contact) H3YN-4-Z H3YN-41-Z Note: Specify both the model number and supply voltage when ordering. Example: H3YN-2 24 VAC Supply voltage Model Number Legend H3YN- - 12 3 1. Output 3. Contact Type 2: DPDT None: Single contact 4: 4PDT Z: Twin contact 2. Time Range None: Short-time range (0.1 s to 10 min) 1: Long-time range (0.1 min to 10 hrs) Accessories (Order Separately) Connecting Socket Timer Track mounting/Frontac ou g/ o Back Connecting Socket CtConnecting SocketiSkt Solder terminal Wire-wrap terminal PC terminal H3YN-2/-21 PYF08A, PYF08A-N, PY08 PY08QN(2) PY08-02 PYF08A-E H3YN-4/-41 PYF14A, PYF14A-N, PY14 PY14QN(2) PY14-02 H3YN-4-Z/-41-Z PYF14A-E 1H3YN H3YN Hold-down Clips Model Applicable Socket Y92H-3 PYF08A, PYF08A-N, PYF08A-E PYF14A, PYF14A-N, PYF14A-E Y92H-4 PY08, PY08QN(2), PY08-02 PY14, PY14QN(2), PY14-02 Specifications Ratings Item H3YN-2/-4/-4-Z H3YN-21/-41/-41-Z Time ranges 0.1 s to 10 min (1 s, 10 s, 1 min, or 10 min 0.1 min to 10 h (1 min, 10 min, 1 h, or 10 h max. selectable) max. selectable) Rated supply voltage 24, 100 to 120, 200 to 230 VAC (50/60 Hz) 12, 24, 48, 100 to 110, 125 VDC (see note 1) Pin type Plug-in Operating mode ON-delay, interval, flicker OFF start, or flicker ON start (selectable with DIP switch) Operating voltage range 85% to 110% of rated supply voltage (12 VDC: 90% to 110% of rated supply voltage) (see note 2) Reset voltage 10% min. of rated supply voltage (see note 3) Power consumption 24 VAC: Relay ON: 1.5 VA (1.1 W) (at 24 VAC, 60 Hz) Relay OFF: 0.2 VA (0.1 W) (at 24 VAC, 60 Hz) 100 to 120 VAC: Relay ON: 1.5 VA (1.3 W) (at 120 VAC, 60 Hz) Relay OFF: 0.6 VA (0.6 W) (at 120 VAC, 60 Hz) 200 to 230 VAC: Relay ON: 1.8 VA (1.5 W) (at 230 VAC, 60 Hz) Relay OFF: 1.2 VA (0.9 W) (at 230 VAC, 60 Hz) 12 VDC: Relay ON: 0.9 W (at 12 VDC) Relay OFF: 0.07 W (at 12 VDC) 24 VDC: Relay ON: 0.9 W (at 24 VDC) Relay OFF: 0.07 W (at 24 VDC) 48 VDC: Relay ON: 1.0 W (at 48 VDC) Relay OFF: 0.2 W (at 48 VDC) 100 to 110 VDC: Relay ON: 1.3 W (at 110 VDC) Relay OFF: 0.3 W (at 110 VDC) 125 VDC: Relay ON: 1.3 W (at 125 VDC) Relay OFF: 0.3 W (at 125 VDC) Control outputs DPDT: 5 A at 250 VAC, resistive load (cos = 1) 4PDT: 3 A at 250 VAC, resistive load (cos = 1) Note: 1. Single-phase, full-wave-rectified power supplies can be used. 2. When using the H3YN continuously in any place where the ambient temperature is in a range of 45C to 50C, supply 90% to 110% of the rated supply voltages (supply 95% to 110% with 12 VDC type). 3. Set the reset voltage as follows to ensure proper resetting. 100 to 120 VAC: 10 VAC max. 200 to 230 VAC: 20 VAC max. 100 to 110 VDC: 10 VDC max. 2