Digital Daily Time Switch H5F CSM H5F DS E 3 1 Daily Time Control with Simple Operations Specify the operation days. (However, you can set only one pattern of operation days and specified days.) Up to 12 ON/OFF operations (2 4 for pulse-output operation). Special holidays can be handled easily with the holiday setting function. Adjustments for sudden schedule changes can be made eas- ily using output override and automatic return operation. The operation program can be checked easily with the pro- gram check function. Enables pulse output operation and summer time setting. Incorporates finger-safe terminals. Conforms to UL, CSA, and CE marking. Meets a variety of mounting requirements: flush mounting, surface mounting, and DIN track mounting. Model Number Structure Model Number Legend H5F- B 12 1. Mounting method None: Flush mounting F: Surface mounting K: Surface mounting/track mounting 2. Language B: English Ordering Information List of Models Wiring Mounting method Model Screw terminals Flush mounting H5F-B Surface mounting H5F-FB Surface mounting/track mounting H5F-KB Accessories (Order Separately) Name Models Soft cover Y92A-48F1 Hard cover For H5F-B Y92A-48 For H5F-FB/-KB Y92A-48E (See note 1.) Flush Mounting Adapter (See note 2.) Y92F-30 Mounting Track 50 cm (l) 7.3 mm (t) PFP-50N 1 m (l) 7.3 mm (t) PFP-100N 1 m (l) 16 mm (t) PFP-100N2 End Plate PFP-M Spacer PFP-S Note: 1. Supplied with H5F-KB model. 2. Supplied with H5F-B (flush-mounting) model. 1H5F Specifications Ratings Rated supply voltage 100 to 240 VAC (50/60 Hz) Operating voltage range 85% to 110% of rated supply voltage Power consumption Approx. 2.4 VA at 264 VAC Control outputs Contact output: SPST-NO, 15 A at 250 VAC, resistive load, 10 A at 24 VDC, resistive load Minimum applied load: 100 mA at 5 VDC (failure level: P, reference value) NEMA A300 Pilot Duty, 1/3 HP at 120 VAC External connections Screw terminals (M3.5 screw) Terminal screw tightening torque 0.98 to 1.17 N m Characteristics Accuracy of operating time 0.01% 0.05 s max. (see note 1) Setting error Influence of voltage Influence of temperature Time accuracy 15 s per month (at 25C) Memory protection Continuous use: 5 years min. (at 25C) Power-interruption rate of 50%: 10 years min. (at 25C) (see note 2) (lithium battery) Insulation resistance 100 M min. (between current-carrying terminals and exposed non-current-carrying metal parts, between operating power supply circuit and control output circuit and between non-continuous contacts) Dielectric strength 2,000 VAC, 50/60 Hz for 1 min (between current-carrying terminals and exposed non-current-carrying metal parts and between operating power supply circuit and control output circuit) 1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts) Noise immunity 1.5 kV (between power terminals) Square-wave noise by noise simulator (pulse width: 100 ns/1 s, 1-ns rise) Vibration resistance Destruction:10 to 55 Hz with 0.375-mm single amplitude, four cycles each in three directions (8 minutes per cycle) Malfunction:10 to 55 Hz with 0.25-mm single amplitude for 10 minutes each in three directions 2 Shock resistance Destruction:300 m/s 3 times each in 6 directions 2 Malfunction:100 m/s 3 times each in 6 directions Ambient temperature Operating:10C to 55C (with no icing) Storage: 25C to 65C (with no icing) Ambient humidity Operating: 35% to 85% Life expectancy Mechanical (at 20C): 100,000 operations min. Electrical (at 20C): 50,000 operations min. (15 A, 250 VAC, resistive load) 50,000 operations min. (1 HP, 250 VAC, motor load) 50,000 operations min. (10 A, 250 VAC, inductive load (cos = 0.7)) 50,000 operations min. (100 W, 100 VAC, lamp load) 10,000 operations min. (300 W, 100 VAC, lamp load) Approved safety standards UL508/Listing, CSA C22.2 No. 14, conforms to EN61010-1 (Pollution degree 2/overvoltage category II) Conforms to VDE0106/P100 (finger protection). Conforms to Electrical Appliance and Material Safety Law (for Japan) EMC (EMI) EN61326 Emission Enclosure: EN55011 Group 1 class A Emission AC mains: EN55011 Group 1 class A (EMS) EN61326 Immunity ESD: EN61000-4-2: 4 kV contact discharge (level 2) 8 kV air discharge (level 3) Immunity RF-interference: EN61000-4-3: 10 V/m (Amplitude-modulated, 80 MHz to 1 GHz, 1.4 to 2 GHz) (level 3) Immunity Conducted Disturbance: EN61000-4-6: 10 V (0.15 to 80 MHz) (according to EN61000-6-2) Immunity Burst: EN61000-4-4: 2 kV power-line (level 3) 1 kV I/O signal-line (level 4) Immunity Surge: EN61000-4-5: 1 kV line to lines (power and output lines) (level 2) 2 kV line to ground (power and output lines) (level 3) Immunity Voltage Dip/Interruption: EN61000-4-11: 0.5 cycle, 100% (rated voltage) Immunity Magnetic Power Field: EN61000-4-8: 30 A/m Case color Light gray (Munsell 5Y7/1) Weight H5F-B: approx. 115 g H5F-KB: approx. 160 g H5F-FB: approx. 130 g Note: 1. The total error including the repeat accuracy, setting error, variation due to voltage change, and variation due to temperature change is 0.01%0.05 s max. 0.01% also indicates an error in the time interval of a set time. 2. The total time when power is not being supplied. 2