General-purpose Limit Switch HL-5000 CSM HL-5000 DS E 3 2 Economical, Miniature Limit Switch Boasting Rigid Construction The Head, Box, and Cover mate with ridged surfaces to maintain strength. A unique Head structure provides a large OT for smooth operation. Easy-to-wire conduit opening design. Ideal for application in printing machines, forming machines, and light machines. (High Switches with high sealing characteristics, such as WL or D4C Switches, in locations subject to oil, water, or precipitation.) Models with grounding terminals conform to the CE marking. Approved by CCC (Chinese standard). (Ask your OMRON representative for information on approved models.) Be sure to read Safety Precautions on page 4 to 5 and Safety Precautions for All Limit Switches. For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Model Number Structure Specifications (Not all combinations are possible. Ask Model Number Legend Approved Standards your OMRON representative for details.) HL-5 Agency Standard File No. HL-5 (1)(2) CCC (CQC) GB14048.5 2003010303077624 (1) Actuators Note: Ask your OMRON representative for information on approved models. 000: Roller lever Ratings 030: Adjustable roller lever 050: Adjustable rod lever Non-inductive load (A) Inductive load (A) 100: Sealed plunger Rated Resistive Inductive Lamp load Motor load 200: Sealed roller plunger voltage load load 300: Coil spring NC NO NC NO NC NO NC NO (2) Ground Terminal Specifications 125 VAC 51.5 0.7 32 1 250 VAC 5 1 0.5 3 1.5 0.8 Blank : Without ground terminal 12 VDC 53 43 G : With ground terminal/M5 tapping on the rear side 24 VDC 53 43 125 VDC 0.4 0.2 Ordering Information 250 VDC 0.4 0.2 Note: 1. The above figures are for steady-state currents. Actuator Model 2. Inductive loads have a power factor of 0.4 min. (AC) and a time constant of 7 ms max. (DC). HL-5000 * Roller lever 3. Lamp load has an inrush current of 10 times the steady-state current. 4. Motor load has an inrush current of 6 times the steady-state current. Adjustable HL-5030 * NC 24 A max. Inrush roller lever current NO 12 A max. Adjustable HL-5050 * Approved Standard Ratings rod lever CCC (GB14048.5) Sealed HL-5100 * Applicable category and ratings plunger AC-15 3 A/250 VAC Sealed roller HL-5200 plunger Coil spring HL-5300 * HL-5000 Limit Switches are offered with a choice of ground terminal/M5 tapping on the rear side conforming to various standards. When placing an order, add the code to the model number to indicate if ground terminal/M5 tapping on the rear side is required. -G: with ground terminal/M5 tapping on the rear side. 1HL-5000 Characteristics Engineering Data Electrical Durability (cos dia. =1) Degree of protection IP65 (Operating temperature: +5C to +35C, 10,000,000 operations min. (under Mechanical Operating humidity: 40% to 70%RH) rated conditions) Durability * Electrical See the following Electrical Durability. Operating frequency: 1,000 30 operations/min Operating speed 5 mm/s to 0.5 m/s 125 VAC (cos dia. = 1) Mechanical 120 operations/min Operating frequency Electrical 30 operations/min Insulation resistance 100 M min. (at 500 VDC) Contact resistance 25 m max. (initial value) 1,000 VAC, 50/60 Hz for 1 min between 500 terminals of the same polarity 1,500 VAC, 50/60 Hz for 1 min between Dielectric strength current-carrying metal parts and ground 1,500 VAC, 50/60 Hz for 1 min between each terminal and non-current-carrying metal part 0 12 3 4 5 6 Rated frequency 50/60 Hz Switching current (A) Vibration Malfunction 10 to 55 Hz, 1.5-mm double amplitude resistance 2 Destruction 1,000 m/s max. Shock 2 resistance Malfunction 300 m/s max. Ambient operating 5C to +65C (with no icing) temperature Ambient operating 35% to 95%RH humidity Weight Approx. 130 to 190 g Note: 1. The above figures are initial values. 2. The above characteristics may vary depending on the model. For further details, contact your OMRON sales representative. * The values are calculated at an operating temperature of +5C to +35C, and an operating humidity of 40% to 70%RH. Contact your OMRON sales representative for more detailed information on other operating environments. Structure and Nomenclature Structure Contact Form Za (NO) 4 3 (NO) Resin roller Lever (NC) 1 2 (NC) Head Cover Built-in switch Connector 2 4 Durability (x 10 operations)