Panel Meters with Advanced Signal Processing Capabilities K3HB K3HB-X/Process Indicator K3HB-V/Weighing Indicator K3HB-H/Temperature Indicator K3HB-S/Linear Sensor Indicator Features Red-Green Display Allows Easy High-speed Sampling at 50 Times per Recognition of Judgement Results Second (20 ms) The measurement value display can be set to switch be- Provides an input sampling cycle at least three times faster tween red and green in accordance with the status of com- than earlier models (12.5 times faster for temperature input parative outputs. This means that the status can be models) at 50 times/second (see note). In addition to im- ascertained at a distance. proved response times for judgement output and transfer output, average processing can be used to increase the sta- Position Meter Enables Easy Monitoring of bility of measurements. Operating Status Trends Note: The K3HB-S Linear Sensor Indicator features high-speed re- sponse of 2,000 times/second. The present value with respect to the measurement or dis- play range (full scale) can be viewed on a bar display. The Sampling at 15 times/second Sampling at 50 times/second operating status can be grasped intuitively, allowing easy judgement of levels and threshold values. Peak value 100 96 HH Timing of Timing of Max H Min internal internal Position meter P B sampling sampling L L T-ZR CMW TG HH H LL Zero Hold TLL L 0 Time Time MAX/MIN LEVEL MODE SHIFT UP Short Body with Depth of Only 95 mm Many Measurement and Discrimination (from Behind the Front Panel) Functions Using External Event Input A short body of only 95 mm (see note) contributes to the de- velopment of slimmer and smaller control panels and instal- Offers a wide variety of application possibilities, such as de- lations. tection and judgement while synchronizing on an external signal. Sampling hold value Input Measurement value 27% Sampling shorter measurement Time than earlier TIMING ON models input OFF Depth: 95 mm (See note.) Input Peak hold value (The depth is 100 mm when mounted to the terminal cover.) Measurement Peak/bottom hold value Note: Depth of DeviceNet models is 97 mm. measurement Bottom hold value Time TIMING OFF input ON Input Peak-to-peak value (b2a2) (b1a1) Peak-to-peak hold Measurement value b1 b2 measurement a1 a2 Time TIMING ON input OFF B-8 K3HB Series K3HBSelect a Comparative Output Pattern to DeviceNet Models Enable High-speed Data Suit the Discrimination or Control Communications with PLCs without Application Special Programming The output pattern for comparative outputs can be selected. DeviceNet compliance enables high-speed data transmis- In addition to high/low comparison with set values, output sion of discrimination results and hold values by allocating based on level changes is also possible. (Use the type of out- setting and monitoring parameters in the I/O memory of the put pattern appropriate for the application.) PLC. This capability greatly reduces labor spent in develop- ing communications programs. Measurement Measurement Standard Output Level Output Comparative Comparative value value set value HH set value HH Higher Higher Comparative Comparative set value H set value H Comparative Comparative set value L set value L Lower Comparative Lower Comparative set value LL set value LL Output HH ON Output HH ON Ethernet OFF OFF Output H Output H Output PASS Output PASS DeviceNet Master Output L Output L Output LL Output LL Measurement Comparative Zone Output value set value HH Higher Comparative set value H Comparative set value L P Lower Comparative H Zero set value LL K3HB Output HH ON Digital Indicators OFF Output H Output PASS P ) Zero DeviceNet Output L Configurator Output LL Note: The HH, H, L, or LL outputs must be set in that order for the zone outputs to output correctly. (This is because the comparative set values and outputs for standard and level outputs are in a 1-to-1 relationship, whereas the meaning of zone outputs depends on the settings of all the comparative set values.) Panel Meter Series K3HB B-9