X-On Electronics has gained recognition as a prominent supplier of K3HB-VLC 100-240VAC Specialist Controllers across the USA, India, Europe, Australia, and various other global locations. K3HB-VLC 100-240VAC Specialist Controllers are a product manufactured by Omron. We provide cost-effective solutions for Specialist Controllers, ensuring timely deliveries around the world.

K3HB-VLC 100-240VAC Omron

K3HB-VLC 100-240VAC electronic component of Omron
Product Image X-ON
Product Image X-ON
Product Image X-ON

Images are for reference only
See Product Specifications
Part No.K3HB-VLC 100-240VAC
Manufacturer: Omron
Category: Specialist Controllers
Description: Controllers Weighing Indicator 100-240VAC
Datasheet: K3HB-VLC 100-240VAC Datasheet (PDF)
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges



Price (USD)
1: USD 720.5006 ea
Line Total: USD 720.5 
Availability - 2
Ship by Wed. 25 Dec to Fri. 27 Dec
MOQ: 1  Multiples: 1
Pack Size: 1
Availability Price Quantity
1
Ship by Fri. 27 Dec to Thu. 02 Jan
MOQ : 1
Multiples : 1
1 : USD 869.1769
3 : USD 839.0812
5 : USD 805.5207
10 : USD 793.4325

2
Ship by Wed. 25 Dec to Fri. 27 Dec
MOQ : 1
Multiples : 1
1 : USD 720.5006
10 : USD 651.9513

   
Manufacturer
Product Category
RoHS - XON
Icon ROHS
Series
Product Type
Packaging
Brand
Factory Pack Quantity :
Hts Code
Subcategory
LoadingGif
 
Notes:- Show Stocked Products With Similar Attributes.

We are delighted to provide the K3HB-VLC 100-240VAC from our Specialist Controllers category, at competitive rates not only in the United States, Australia, and India, but also across Europe and beyond. A long established and extensive electronic component distribution network has enhanced our global reach and dependability, ensuring cost savings through prompt deliveries worldwide. Client satisfaction is at the heart of our business, where every component counts and every customer matters. Our technical service team is ready to assist you. From product selection to after-sales support, we strive to deliver a seamless and satisfying experience. Are you ready to experience the best in electronic component distribution? Contact X-ON Electronics today and discover why X-On are a preferred choice for the K3HB-VLC 100-240VAC and other electronic components in the Specialist Controllers category and beyond.

Image Part-Description
Stock Image K3HBVLC24VACVDC
Weighing Indicator Asy Recognition Of Judgement Results Using Color Display
Stock : 1
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image K3HB-XAD 24VAC/VDC
Process Controllers Process Indicator 24VAC/VDC DC Curr
Stock : 2
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image K3HB-VLC 24VAC/VDC
Controllers Weighing Indicator 24VAC/VDC
Stock : 2
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image K3HB-XAD 100-240VAC
Controllers Process Indicator 100-240VAC DC Curr
Stock : 0
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image K3HB-XAA 100-240VAC
Controllers ProcMtr ACcurrnt in 100-240VAC
Stock : 1
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image K3HBXAD24VACVDC
Process Indicator Ideal For Discriminating And Displaying Measurements For Voltage/Current Signals
Stock : 3
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image K3HB-XVA 100-240VAC
Controllers AC Volt Input 100-2 40 VAC
Stock : 2
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image K3HB-XVA 24VAC/VDC
Controllers AC Volt Input 24 VA C/DC
Stock : 0
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image K3HB-XAA 24VAC/VDC
Controllers AC Current Input 24 VAC/DC
Stock : 0
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Image Part-Description
Stock Image K3HB-XAA 100-240VAC
Controllers ProcMtr ACcurrnt in 100-240VAC
Stock : 1
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image K3HBXAD24VACVDC
Process Indicator Ideal For Discriminating And Displaying Measurements For Voltage/Current Signals
Stock : 3
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image K3MA-F-A2 100-240VAC
Controllers Frequency/Rate Meter 100-240VAC 2 Relay
Stock : 5
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image K3MA-L 100-240VAC
Controllers TEMPERATURE METER W/ NO OUTPUT
Stock : 0
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image K3MA-L-C 100-240VAC
Controllers Temp Meter 100-240VAC 1 Relay
Stock : 3
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image K3SC-10 AC100-240
Controllers RS-232/USBto-422/485 CONVERTER
Stock : 0
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image K33-L2A
Controllers 12VDC PS w/Analog Volt
Stock : 0
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image K34-C2
Controllers 63HB HH/H/L/LL RLYOUTPUT BRD
Stock : 6
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Hot Stock Image K3MA-J 100-240VAC
Process Controllers PROCESS METER WITH N O OUTPUT
Stock : 23
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.
Stock Image K3TF-V714
Controllers PANEL METERAC INPUTS
Stock : 0
This product is classified as Large/Heavy, additional shipping charges may apply. A customer service representative may contact you after ordering to confirm exact shipping charges.

Weighing Indicator K3HB-V CSM K3HB-V DS E 11 4 An Ideal Indicator for OK/NG Judgements in Automated and Picking Machines, Measuring Factors such as Pressure, Load, Torque, and Weight Using Load Cell Signal Input. Easy recognition of judgement results using color display that can be switched between red and green. * Equipped with a position meter for monitoring operating status trends. External event input allows use in various measurement and discrimination applications. Input 0.001 mVDC or higher (0.000 to 19.999 mV range supported). External power takeoff of 100 mA at 10 VDC provided. (Models with 5-VDC power takeoff also available.) Series expanded to include DeviceNet models. Short body with depth of only 95 mm (from behind the front panel), or 97 mm for DeviceNet models. UL certification approval (Certification Mark License). CE Marking conformance by third party assessment body. For the most recent information on models that have been certified for Water-resistant enclosure conforms to NEMA 4X (equivalent to IP66). safety standards, refer to your OMRON website. Capable of high-speed sampling at 50 times per second (20 ms) Easy-to-set two-point scaling allows conversion and display of any user-set values. Refer to Safety Precautions for All Digital Panel * Visual confirmation of judgement results is not supported on models that do not have an Meters. output or models that do not support DeviceNet. You can change the display color by setting it, but you cannot switch it based on the judgement results. Model Number Structure Model Number Legend Base Units and Optional Boards can be ordered individually or as sets. Base Units Base Units with Optional Boards K3HB-V - K3HB-V 12 34 5 1 5 2. Sensor Power Supply/Output Type Code 1. Input Sensor Code None: None LC: Load cell input (DC low-voltage input) CPB: Relay output (PASS: SPDT) + Sensor power supply (10 VDC +/5%, 100 mA) (See note 1.) 5. Supply Voltage L1B: Linear current output (0 to 20 or 4 to 20 mA DC) + Sensor power supply (10 VDC +/5%, 100 mA) (See note 2.) 100-240 VAC: 100 to 240 VAC L2B: Linear voltage output (0 to 5, 1 to 5, or 0 to 10 VDC) + Sensor 24 VAC/VDC: 24 VAC/VDC power supply (10 VDC +/5%, 100 mA) (See note 2.) B: Sensor power supply (10 VDC +/5%, 100 mA) FLK1B: Communications (RS-232C) + Sensor power supply (10 VDC +/5%, 100 mA) (See note 2.) FLK3B: Communications (RS-485) + Sensor power supply (10 VDC +/5%, 100 mA) (See note 2.) CPE: Relay output (PASS: SPDT) + Sensor power supply (5 VDC +/5%, 100 mA) (See note1.) L1E: Linear current output (DC0(4) 20 mA) + Sensor power supply (5 VDC +/5%, 100 mA) (See note 2.) L2E: Linear voltage output (DC0(1) 5 V, 010 V)+ Sensor power supply (5 VDC +/5%, 100 mA) (See note 2.) E: Sensor power supply (5 VDC +/5%, 100 mA) FLK1E: Communications (RS-232C) + Sensor power supply (5 VDC +/5%, 100 mA) (See note 2.) FLK3E: Communications RS-485) + Sensor power supply (5 VDC +/5%, 100 mA) (See note 2.) Note: 1. CPA can be combined with relay outputs only. 2. Only one of the following can be used by each Digital Indicator: RS- 232C/RS-485 communications, a linear output, or DeviceNet communications. Optional Boards 3. Relay/Transistor Output Type Code Sensor Power Supply/Output Boards None: None C1: Relay contact (H/L: SPDT each) K33- C2: Relay contact (HH/H/LL/L: SPST-NO each) 2 T1: Transistor (NPN open collector: HH/H/PASS/L/LL) Relay/Transistor Output Boards T2: Transistor (PNP open collector: HH/H/PASS/L/LL) BCD *: BCD output + transistor output (NPN open collector: HH/H/PASS/L/LL) DRT: DeviceNet (See note 2.) K34- * A Special BCD Output Cable (sold separately) is required. 3 4. Event Input Type Code Event Input Boards None: None 1: 5 inputs (M3 terminal blocks), NPN open collector K35- 2 *: 8 inputs (10-pin MIL connector), NPN open collector 3: 5 inputs (M3 terminal blocks), PNP open collector 4 4 *: 8 inputs (10-pin MIL connector), PNP open collector * There is no bank selection forNon andDeviceNe types ofTransistor Output Type Cod. Note: The following combinations are not possible. Communications (FLK B/E) + DeviceNet (DRT) Communications (FLK B/E) + BCD output (BCD) Linear current/voltage (L B/E) + DeviceNet (DRT) 1K3HB-V Accessories (Sold Separately) K32-DICN: Special Cable (for event inputs, with 8-pin connector) K32-BCD: Special BCD Output Cable Watertight Cover Rubber Packing Model Model K32-P1 Y92A-49N Note: Rubber packing is provided with the Controller. Specifications Ratings Power supply voltage 100 to 240 VAC (50/60 Hz), 24 VAC/VDC, DeviceNet power supply: 24 VDC Allowable power supply voltage range 85% to 110% of the rated power supply voltage, DeviceNet power supply: 11 to 25 VDC Power consumption 100 to 240 V: 18 VA max. (max. load) (See note 1.) 24 VAC/DC: 11 VA/7 W max. (max. load) Current consumption DeviceNet power supply: 50 mA max. (24 VDC) Input DC voltage A/D conversion method Delta-Sigma method External power supply 10 VDC 5%, 100 mA (models with external power supply only) or 5 VDC, 100 mA (models with external power supply only) Event inputs Timing input NPN open collector or no-voltage contact signal (See note 2.) ON residual voltage: 3 V max. ON current at 0 : 17 mA max. Max. applied voltage: 30 VDC max. OFF leakage current: 1.5 mA max. Startup compensation NPN open collector or no-voltage contact signal timer input ON residual voltage: 2 V max. ON current at 0 : 4 mA max. Hold input Max. applied voltage: 30 VDC max. Reset input OFF leakage current: 0.1 mA max. Forced-zero input Bank input Output ratings (depends Relay output 250 VAC, 30 VDC, 5 A (resistive load) on the model) Mechanical life expectancy: 5,000,000 operations, Electrical life expectancy: 100,000 operations Transistor output Maximum load voltage: 24 VDC, Maximum load current: 50 mA, Leakage current: 100 A max. Linear output Linear output 0 to 20 mA DC, 4 to 20 mA DC: Load: 500 max, Resolution: Approx. 10,000, Output error: 0.5% FS Linear output 0 to 5 VDC, 1 to 5 VDC, 0 to 10 VDC: Load: 5 k max, Resolution: Approx. 10,000, Output error: 0.5% FS (1 V or less: 0.15 V no output for 0 V or less) Display method Negative LCD (backlit LED) display 7-segment digital display (Character height: PV: 14.2 mm (green/red) SV: 4.9 mm (green) Main functions Scaling function, measurement operation selection, averaging, previous average value comparison, forced- zero, zero-limit, output hysteresis, output OFF delay, output test, teaching, display value selection, display color selection, key protection, bank selection, display refresh period, maximum/minimum hold, reset Ambient operating temperature 10 to 55C (with no icing or condensation) Ambient operating humidity 25% to 85% Storage temperature 25 to 65C (with no icing or condensation) Altitude 2,000 m max. Accessories Watertight packing, 2 fixtures, terminal cover, unit stickers, operation manual. DeviceNet models also include a DeviceNet connector (Hirose HR31-5.08P-5SC(01)) and crimp terminals (Hirose HR31-SC-121) (See note 3.) Note: 1. DC power supply models require a control power supply capacity of approximately 1 A per Unit when power is turned ON. Particular attention is required when using two or more DC power supply models. The OMRON S8VS-series DC Power Supply Unit is recommended. 2. PNP input types are also available. 3. For K3HB-series DeviceNet models, use only the DeviceNet Connector included with the product. The crimp terminals provided are for Thin Cables. 2

Tariff Desc

8473.30.00 - Parts and accessories of the machines of 8471 AUTOMATIC DATA PROCESSING MACHINES AND UNITS THEREOF; MAGNETIC OR OPTICAL READERS, MACHINES FOR TRANSCRIBING DATA ONTO DATA MEDIA IN CODED FORM AND MACHINES FOR PROCESSING SUCH DATA, NOT ELSEWHERE SPECIFIED OR INCLUDED: Free
62 No .Cards (including network, sound, video, IDE, SCSI, and other similar cards)
Omron Automation
Omron Automation & Safety
Omron Automation and Safety
OMRON AUTOMATION CANADA
OMRON ELECTRONIC COM
OMRON ELECTRONIC COMPONENTS
OMRON ELECTRONICS
Omron Electronics In
Omron Electronics Inc-EMC Div
Omron Electronics Inc-IA Div
OMRON INDUSTRIAL
OMRON INDUSTRIAL AUTOMATION
Omron Industrial Products
OMRON OCB
OMRON SAFETY
OMRON STI
Best Retailer of the LPH-14-S-B Headers & Wire Housings in India image

Sep 9, 2024
Discover why Xon Electronic is the best global retailer for the **LPH-14-S-B Headers & Wire Housings** by Itek. This 14-way low-profile header offers superior durability, secure connections, and high current capacity, making it ideal for applications in consumer electronics, automotive, telecommuni
R15-2013-23-5230-WTL Industrial Relays by Relpol Retailers image

Dec 11, 2024
Discover the R15-2013-23-5230-WTL Industrial Relay by Relpol, available at Xon Electronics. This electromagnetic 3PDT relay features a 230VAC coil voltage and a robust switching capacity of 10A for 250VAC or 24VDC applications. Designed for industrial automation, motor control, and power systems, i
Linear Voltage Regulator image

Nov 29, 2021
Uncover the advantages of a linear voltage regulator in maintaining a constant voltage supply. Improve your devices' performance. Upgrade now for seamless power management!
97-3101A-14S-6P Circular MIL Spec Connector by Amphenol image

Nov 11, 2024
The 97-3101A-14S-6P Circular MIL Spec Connector by Amphenol is a reliable, high-performance connector featuring a 6-pin configuration, 14S shell size, and solder termination. Widely used in military, aerospace, and industrial applications, it ensures secure, durable connections even in harsh cond

Looking for help? Visit our FAQ's Section to answer to all your questions

 

X-ON Worldwide Electronics

Welcome To X-ON Electronics
For over three decades, we have been advocating and shaping the electronic components industry. Our management complements our worldwide business scope and focus. We are committed to innovation, backed by a strong business foundation. If you need a trustworthy supplier of electronic components for your business – look no further.
 

Copyright ©2024  X-ON Electronics Services. All rights reserved.
Please ensure you have read and understood our Terms & Conditions before purchasing. All prices exclude GST.

Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted Image for all the cards that are accepted AS9120 Certified