General-purpose Relay
MY New model
Versatile and Function-filled Miniature Power
Relay for Sequence Control and Power
Switching Applications
Models with lockable test buttons now available.
Many variations possible through a selection of operation indi-
cators (mechanical and LED indicators), lockable test button,
built-in diode and CR (surge suppression), bifurcated contacts,
etc.
Arc barrier standard on 4-pole Relays.
Dielectric strength: 2,000 VAC (coil to contact)
Environment-friendly cadmium-free contacts.
Safety standard approvals obtained.
LR
Wide range of Sockets (PY, PYF Series) and optional parts are
available.
Max. Switching Current: 2-pole: 10 A, 4-pole: 5 A
Provided with nameplate.
Ordering Information
Relays
Standard Coil Polarity
Type Contact form Plug-in socket/Solder terminals Without LED indicator
Standard with LED indicator With LED indicator and
lockable test button
Standard DPDT MY2N MY2IN MY2
4PDT MY4N MY4IN MY4
4PDT (bifurcated) MY4ZN MY4ZIN MY4Z
With built-in diode DPDT MY2N-D2 MY2IN-D2 ---
(DC only)
4PDT MY4N-D2 MY4IN-D2 ---
4PDT (bifurcated) MY4ZN-D2 MY4ZIN-D2 ---
With built-in CR DPDT MY2N-CR MY2IN-CR ---
(220/240 VAC, 110/120 VAC
4PDT MY4N-CR MY4IN-CR ---
only)
4PDT (bifurcated) MY4ZN-CR MY4ZIN-CR ---
Reverse Coil Polarity
Type Contact form Plug-in socket/Solder terminals
With LED indicator With LED indicator and
lockable test button
Standard (DC only) DPDT MY2N1 MY2IN1
4PDT MY4N1 MY4IN1
4PDT (bifurcated) MY4ZN1 MY4ZIN1
With built-in diode DPDT MY2N1-D2 MY2IN1-D2
(DC only)
4PDT MY4N1-D2 MY4IN1-D2
4PDT (bifurcated) MY4ZN1-D2 MY4ZIN1-D2
Note: When ordering, add the rated coil voltage and (s) to the model number. Rated coil voltages are given in the coil ratings table.
Example: MY2 6VAC (S)
New model
Rated coil voltage
General-purpose Relay MY New model 1 Accessories (Order Separately)
Sockets
Poles Front-mounting Back-mounting Socket
Socket (DIN-track/
Solder terminals Wire-wrap terminals PCB terminals
screw mounting)
Without clip With clip Without clip With clip
2 PYF08A-E PY08 PY08-Y1 PY08QN PY08QN-Y1 PY08-02
PYF08A-N PY08QN2 PY08QN2-Y1
4 PYF14A-E PY14 PY14-Y1 PY14QN PY14QN-Y1 PY14-02
PYF14A-N PY14QN2 PY14QN2-Y1
Socket Hold-down Clip Pairing
Relay type Poles Front-connecting Socket (DIN-track/ Back-connecting Socket
screw mounting)
Solder/Wire-wrap terminals PCB terminals
Socket Clip Socket Clip Socket Clip
Without 2-pole test 2 PYF08A-E PYC-A1 PY08(QN) PYC-P PY08-02 PYC-P
button PYF08A-N PYC-P2 PYC-P2
4 PYF14A-E PY14(QN) PY14-02
PYF14A-N
2-pole test button 2 PYF08A-E PYC-E1 PY08(QN) PYC-P2 PY08-02 PYC-P2
PYF08A-N
Mounting Plates for Sockets
Socket model For 1 Socket For 18 Sockets For 36 Sockets
PY08, PY08QN(2), PY14, PY14QN(2) PYP-1 PYP-18 PYP-36
Note: PYP-18 and PYP-36 can be cut into any desired length in accordance with the number of Sockets.
Track and Accessories
Supporting Track (length = 500 mm) PFP-50N
Supporting Track (length = 1,000 mm) PFP-100N, PFP-100N2
End Plate PFP-M
Spacer PFP-S
Specifications
Coil Ratings
Rated voltage Rated current Coil Coil inductance Must Must Max. Power
resistance (reference value) operate release voltage consumption
voltage voltage (approx.)
50 Hz 60 Hz Arm. OFF Arm. ON % of rated voltage
AC 6 V* 214.1 mA 183 mA 12.2 0.04 H 0.08 H 80% max. 30% min. 110% 1.0 to 1.2 VA
(60 Hz)
12 V 106.5 mA 91 mA 46 0.17 H 0.33 H
24 V 53.8 mA 46 mA 180 0.69 H 1.30 H
48/50 V* 24.7/ 21.1/ 788 3.22 H 5.66 H
25.7 mA 22.0 mA
110/120 V 9.9/10.8 mA 8.4/9.2 mA 4,430 19.20 H 32.1 H 0.9 to 1.1 VA
(60 Hz)
220/240 V 4.8/5.3 mA 4.2/4.6 mA 18,790 83.50 H 136.4 H
DC 6 V* 151 mA 39.8 0.17 H 0.33 H 10% min. 0.9 W
12 V 75 mA 160 0.73 H 1.37 H
24 V 37.7 mA 636 3.20 H 5.72 H
48 V* 18.8 mA 2,560 10.60 H 21.0 H
100/110 V 9.0/9.9 mA 11,100 45.60 H 86.2 H
Note: 1. The rated current and coil resistance are measured at a coil temperature of 23C with tolerances of +15%/20% for rated currents and
15% for DC coil resistance.
2. Performance characteristic data are measured at a coil temperature of 23C.
3. AC coil resistance and impedance are provided as reference values (at 60 Hz).
4. Power consumption drop was measured for the above data. When driving transistors, check leakage current and connect a bleeder re-
sistor if required.
5. Rated voltage denoted by * will be manufactured upon request. Ask your OMRON representative.
2 General-purpose Relay MY New model