Limit Touch Switch NL CSM NL DS E 2 2 Object Actuates Switch and Turns Built-in Monitor Indicator ON Instantaneous operation upon contact with extremely limited hysteresis for high-precision position detection. Detects minute displacement or lightweight objects with minimal operating force. Built-in LED indicator ensures easy operation monitoring. DC models provide versatile functions in combination with the S3D2 Sensor Controller. Be sure to read Safety Precautions on page 6 to 7 and Safety Precautions for All Limit Switches. Application Examples Detection of press completion position. Drill positioning. Detection of workpiece edges. Detection of mistakes in workpiece Material positioning. setting or removal. Detection of minute workpieces. Press Workpiece NL NL NL Paper (cloth) Grounding Grounding rod rod NL NL (Ground) Detection of paper or cloth edge Displacement detection and control. Thickness control of rolling plates. (using indirect grounding). Pressure NL Paper (cloth) NL Roller Ground side Bellows Detection of paper or cloth seam (using indirect grounding). NL Controller Motor NL Controller Unit Unit NL Grounding rod Paper (cloth) 1NL Ordering Information Built-in Antenna Model Model Built-in antenna model Provides sufficient OT (overtravel). Ensures high-precision positioning control. Features Antenna tip withstands bending. OT of 5-mm max. (overtravel) Coil spring Plunger Antenna Series Power supply voltage Model Model NL1 12 VDC NL1-C NL1-P NL2 24 VDC NL2-C NL2-P 100 VAC NL3-C 100V NL3-P 100V NL3 200 VAC NL3-C 200V NL3-P 200V Antenna only NL1-C ANTENNA ASSY (Same for NL1, NL2, and NL3) --- Note: Each model is provided with a standard 1-m cable. Separate Antenna Model Model Separate antenna model Features Antenna with 3-m extension cable is available for narrow spaces where conventional limit switches cannot be used. No antenna Plunger Coil spring with antenna with antenna Antenna Series Power supply voltage Model Model Model NL1 12 VDC NL1-S NL1-SP NL1-SC NL2 24 VDC NL2-S NL2-SP NL2-SC Antenna only --- --- NL1-SC ANTENNA (Same for NL1 and NL2) Note: Each model is provided with a standard 1-m cable. Specifications Item Model NL1 NL2 NL3 Degree of protection IP60 Supply voltage 12 VDC 24 VDC 100 VAC or 200 VAC Rated frequency --- 50/60 Hz Grounded object: Contact resistance of 3 k max. Sensitivity Non-grounded object: Antenna-to-ground capacitance of 100 pF min. Current consumption 8 mA 15 mA --- Leakage current --- Circuit: 2 mA Antenna: 1 mA *1 Response time 5 ms max. 20 ms max. Voltage output model: 30 mA at Current output model: Thyristor output model: Output signal 12 VDC with output 24 VDC (directly switching 100 or 200 VAC (directly switching resistive impedance of 4.7 k resistive load of 170 mA max.) load of 30 to 300 mA) *2 Insulation resistance 0 V (blue lead wire) is connected to casing 100 M min. at 500 VDC *3 Dielectric strength 0 V (blue lead wire) is connected to casing 1,500 VAC at 50/60 Hz for 1 min *3 Pollution degree 3 (IEC947-5-1) (operating environment) Protection against Class II electric shock Proof tracking index (PTI) 175 Switch category D (IEC335) Vibration resistance 10 to 55 Hz, 1.5-mm double amplitude 2 Shock resistance 200 m/s max. Ambient temperature 10C to +60C (with no icing) Ambient humidity 35% to 95%RH Weight Approx. 370 g (NL -C, -P) Approx. 550 g (NL -S) Approx. 680 g (NL -SP, -SC) *1. The NL3 has a capacitor and resistor for the protection of the built-in SCR. Therefore, the NL3 has leakage current. *2. The NL3 requires a current of 30 mA for circuit protection. Red (Brown) If the load current is less than 30 mA, connect the bleeder resistance R in i Power supply Load parallel with the load as shown below so that the total current of the load circuit will be 30 to 300 mA. White 100 VAC (Black) (200 VAC) Obtain R from the following formula. R NL3 Black (Blue) V R= (k) 30 i Make sure that the permissible power of the resistor is sufficient. *3. Between current-carrying and non-current-carrying metal parts 2