Switch Mode Power Supply ( ) S8PS 50/100/150/300/600-W Models Compact DIN Rail-mounting Power Supplies Complies with EN 61000-3-2 harmonic current standards. Safety standards: UL, CSA, and EN/VDE. Complies with EN 61204-3 Class B. Mounting Bracket included for front mounting or DIN Rail mount- ing. RoHS-compliant Note: Refer to Safety Precautions on page 12. Model Number Structure Model Number Legend Note: Not all combinations are possible. Refer to List of Models in Ordering Information, below. 2. Output Voltage S8PS- 05: 5 V 1 2 3 12: 12 V 1. Power Ratings 24: 24 V 050: 50 W 3. Configuration 100: 100 W C: Covered type with Front Mounting Bracket 150: 150 W D: Open-frame type with DIN Rail Mounting Bracket 300: 300 W CD: Covered type with DIN Rail Mounting Bracket 600: 600 W None: Open-frame type with Front Mounting Bracket Ordering Information List of Models Note: For details on normal stock models, contact your nearest OMRON representative. Configuration Input voltage Power ratings Output voltage Output current Front-mounting DIN Rail-mounting Model Model Covered type 100 to 240 VAC 50 W 5 V 10 A S8PS-05005C S8PS-05005CD 12 V 4.2 A S8PS-05012C S8PS-05012CD 24 V 2.1 A S8PS-05024C S8PS-05024CD 100 W 24 V 4.5 A S8PS-10024C S8PS-10024CD 150 W 24 V 6.5 A S8PS-15024C S8PS-15024CD 300 W 24 V 14 A S8PS-30024C S8PS-30024CD 600 W 24 V 27 A S8PS-60024C --- Open-frame type 100 to 240 VAC 50 W 5 V 10 A S8PS-05005 S8PS-05005D 12 V 4.2 A S8PS-05012 S8PS-05012D 24 V 2.1 A S8PS-05024 S8PS-05024D 100 W 24 V 4.5 A S8PS-10024 S8PS-10024D 150 W 24 V 6.5 A S8PS-15024 S8PS-15024D Options (Order Separately) Name Model Fan S82Y-JFAN S8PS Specifications Ratings/Characteristics Item 50 W 100 W 150 W 300 W 600 W Efficiency (typical) 74% to 80% (depends on the model) Input Voltage (See note 1.) 100 to 240 VAC (85 to 264 VAC) Frequency (See note 1.) 50/60 Hz (47 to 63 Hz) Current (See note 2.) 100-V input 0.9 A max. 1.8 A max. 2.7 A max. 5.4 A max. 10 A max. 200-V input 0.45 A max. 0.9 A max. 1.4 A max. 2.7 A max. 5 A max. Leakage current (See note 2.) 100-V input 0.5 mA max. 200-V input 1.0 mA max. Inrush current (See note 2.) 100-V input 25 A max. (for a cold start at 25C) 200-V input 50 A max. (for a cold start at 25C) Power factor (See note 2.) 0.95 typical Harmonic current standards Based on EN Complies with EN 61000-3-2 61000-3-2 Output Voltage adjustment range (See note 3.) 5% to 10% Ripple (See note 2.) 2% (p-p) max. Input variation influence 0.4% max. (at 85 to 132 VAC input/at 170 to 264 VAC input, 100% load) Load variation influence 0.8% max. (with rated input, 0 to 100% load) Temperature variation influence (See note 2.) 0.05%/C max. Startup time 1,000 ms max. (up to 90% of output voltage at rated out- 1,500 ms max. put voltage/current) Hold time (See note 2.) 20 ms min. Additional Overload protection 105% min., voltage drop, intermittent operation function (With the 600-W model, output is turned OFF at 5 s min.) Overvoltage protection (See note 5.) Yes Overheat protection No Yes Protection-ON alarm indicator No Yes (color: red) Parallel operation No Yes, 2 units max. Other Heat radiation Natural air-cooling Built-in fan Ambient operating temperature Refer to the derating curve in Engineering Data (with no icing or condensation). Storage temperature 25 to 65C Ambient operating humidity 25% to 85% Dielectric strength 3.0 kVAC for 1 min. (between all inputs and outputs) 2.2 kVAC for 1 min. (between all inputs and PE terminal) 1.0 kVAC for 1 min. (between all outputs and PE terminal) Insulation resistance 100 M min. (between all outputs and inputs/PE terminal at 500 VDC) Vibration resistance 10 to 55 Hz, 0.75-mm amplitude for 2 h each in X, Y, and Z directions 2 Shock resistance 300 m/s , 3 times each in X, Y, and Z directions Output indicator Yes (color: green) EMI Conducted Conforms to EN61204-3 EN55011 Class B and based on FCC Class B Emission (See note 2.) Radiated Conforms to EN61204-3 EN55011 Class B Emission EMS Conforms to EN61204-3 High severity levels Approved standards UL UL508, UL1012, UL60950-1 cUL CSA C22.2 No. 14 cUR CSA No. 60950-1 EN/VDE EN50178 (=VDE0160), EN60950-1 (=VDE0805 Teil 1) Weight (See note 6.) 420 g max. 600 g max. 735 g max. 2,200 g max. 3,500 g max. Mounting method Front Mounting Bracket or DIN Rail Mounting Bracket Front Mounting Bracket Note: 1. Do not use an inverter output for the Power Supply. Inverters with an output frequency of 50/60 Hz are available, but the rise in the internal temperature of the Power Supply may result in ignition or burning. 2. A 100% load for rated input voltage (100 VAC or 200 VAC). 3. If the output voltage adjuster (V. ADJ) is turned, the voltage will increase by more than 10% of the voltage adjustment range. When ad- justing the output voltage, confirm the actual output voltage from the Power Supply and be sure that the load is not damaged. 4. The output will shut off and the protection-ON alarm indicator will simultaneously light. Turn OFF the input power supply, wait 1 min., and then turn ON the input power supply to recover normal operation. 5. Turn OFF the input power supply, wait 1 min., and then turn ON the input power to recover normal operation. (For 300-W and 600-W models, the output will shut off and the protection-ON indicator will simultaneously light.) 6. The weight indicated is for a front-mounting open-frame model. (includes the cover for 300-W and 600-W front-mounting models.)