Switch Mode Power Supply
S8VM (15/30/50/100/150/300/600/1,500-W Models)
Power Supply Featuring OMRONs Unique, New Undervoltage Alarm Function with
Compact Body Contributing to Machine Downsizing
New undervoltage alarm function assists in determining causes of errors (S8VM-@@@24A@/P@ only).
Power failure alarm function provides notification of output voltage errors (300-, 600-, and 1,500-W models only).
Broad range of possibilities with 8 capacities and 29 models to choose from.
RoHS-compliant including lead-free construction.
Safety standards: UL508/60950-1/1604, CSA C22.2 No. 14/No. 60950-1/No. 213, EN50178, EN60950-1 (The 300-, 600-, and
1,500-W models will not conform to safety standards if the customer replaces the fan.)
Harmonic current emissions: Conforms to EN61000-3-2 (except for 15- and 30-W models).
New, attentive design prevents screws from falling out of terminal block (except for output terminals of 300-, 600-, and 1,500-W
models).
Finger protection prevents electric shock.
DIN Rail mounting.
Note: Refer to Precautions for Safe Use on page 32.
Model Number Structure
Model Number Legend
Note: Not all combinations are possible. Please refer to the list of models in Ordering Information on page 2.
S8VM- @@@@@@@
12 3 4
1. Power Ratings 3. Configuration/Functions
015: 15 W None: Open-frame type Standard type
030: 30 W C: Covered type Standard type
050: 50 W A: Covered type Undervoltage alarm type (Sinking)
(See note 1.)
100: 100 W
P: Covered type Undervoltage alarm type (Sourcing)
150: 150 W
(See note 1.)
300: 300 W
600: 600 W
4. Configuration
152: 1,500 W
None Bottom mounting type (See note 2.)
2. Output Voltage D DIN Rail mounting bracket type
05: 5 V
12: 12 V
15: 15 V
24: 24 V
Note: 1. The housing and terminal of the connector for the undervoltage alarm output are provided with the S8VM-05024A@/P@, S8VM-
10024A@/P@ and S8VM-15024A@/P@.
2. Bottom mounting models cannot be used for front mounting. For a front mounting configuration, use a DIN Rail mounting bracket model
or Mounting Brackets (sold separately).
3. A forced-air cooling method with a fan is used with 300-, 600-, and 1,500-W models.
Switch Mode Power Supply S8VM 1Ordering Information
Note: For details on normal stock models, contact your nearest OMRON representative.
Configura- Power Input voltage Output voltage Output current Bottom mounting DIN Rail mounting bracket
tion ratings
Standard model Undervoltage alarm model Standard model Undervoltage alarm model
Sinking Sourcing Sinking Sourcing
Open-frame 15 W 100 to 240 VAC 5 V 3 A S8VM-01505 --- --- S8VM-01505D --- ---
type
12 V 1.3 A S8VM-01512 --- --- S8VM-01512D --- ---
15 V 1 A S8VM-01515 --- --- S8VM-01515D --- ---
24 V 0.65 A S8VM-01524 --- --- S8VM-01524D --- ---
30 W 5 V 6 A S8VM-03005 --- --- S8VM-03005D --- ---
12 V 2.5 A S8VM-03012 --- --- S8VM-03012D --- ---
15 V 2 A S8VM-03015 --- --- S8VM-03015D --- ---
24 V 1.3 A S8VM-03024 --- --- S8VM-03024D --- ---
50 W 5 V 10 A S8VM-05005 --- --- S8VM-05005D --- ---
12 V 4.3 A S8VM-05012 --- --- S8VM-05012D --- ---
15 V 3.5 A S8VM-05015 --- --- S8VM-05015D --- ---
24 V 2.2 A S8VM-05024 --- --- S8VM-05024D --- ---
100 W 5 V 20 A S8VM-10005 --- --- S8VM-10005D --- ---
12 V 8.5 A S8VM-10012 --- --- S8VM-10012D --- ---
15 V 7 A S8VM-10015 --- --- S8VM-10015D --- ---
24 V 4.5 A S8VM-10024 --- --- S8VM-10024D --- ---
150 W 5 V 27 A S8VM-15005 --- --- S8VM-15005D --- ---
(See note 2.) (See note 2.)
12 V 12.5 A S8VM-15012 --- --- S8VM-15012D --- ---
15 V 10 A S8VM-15015 --- --- S8VM-15015D --- ---
24 V 6.5 A S8VM-15024 --- --- S8VM-15024D --- ---
Covered 15 W 100 to 240 VAC 5 V 3 A S8VM-01505C --- --- S8VM-01505CD --- ---
type
12 V 1.3 A S8VM-01512C --- --- S8VM-01512CD --- ---
15 V 1 A S8VM-01515C --- --- S8VM-01515CD --- ---
24 V 0.65 A S8VM-01524C S8VM-01524A (See note 1.) S8VM-01524CD S8VM-01524AD (See note 1.)
30 W 5 V 6 A S8VM-03005C --- --- S8VM-03005CD --- ---
12 V 2.5 A S8VM-03012C --- --- S8VM-03012CD --- ---
15 V 2 A S8VM-03015C --- --- S8VM-03015CD --- ---
24 V 1.3 A S8VM-03024C S8VM-03024A (See note 1.) S8VM-03024CD S8VM-03024AD (See note 1.)
50 W 5 V 10 A S8VM-05005C --- --- S8VM-05005CD --- ---
12 V 4.3 A S8VM-05012C --- --- S8VM-05012CD --- ---
15 V 3.5 A S8VM-05015C --- --- S8VM-05015CD --- ---
24 V 2.2 A S8VM-05024C S8VM-05024A S8VM-05024P S8VM-05024CD S8VM-05024AD S8VM-05024PD
100 W 5 V 20 A S8VM-10005C --- --- S8VM-10005CD --- ---
12 V 8.5 A S8VM-10012C --- --- S8VM-10012CD --- ---
15 V 7 A S8VM-10015C --- --- S8VM-10015CD --- ---
24 V 4.5 A S8VM-10024C S8VM-10024A S8VM-10024P S8VM-10024CD S8VM-10024AD S8VM-10024PD
150 W 5 V 27 A S8VM-15005C --- --- S8VM-15005CD --- ---
(See note 2.) (See note 2.)
12 V 12.5 A S8VM-15012C --- --- S8VM-15012CD --- ---
15 V 10 A S8VM-15015C --- --- S8VM-15015CD --- ---
24 V 6.5 A S8VM-15024C S8VM-15024A S8VM-15024P S8VM-15024CD S8VM-15024AD S8VM-15024PD
300 W 5 V 60 A S8VM-30005C --- --- --- --- ---
(See note
12 V 27 A S8VM-30012C --- --- --- --- ---
4.)
15 V 22 A S8VM-30015C --- --- --- --- ---
24 V 14 A S8VM-30024C --- --- --- --- ---
Peak current:
16.5 A (200 VAC)
600 W 5 V 120 A S8VM-60005C --- --- --- --- ---
(See note
12 V 53 A S8VM-60012C --- --- --- --- ---
4.)
15 V 43 A S8VM-60015C --- --- --- --- ---
24 V 27 A S8VM-60024C --- --- --- --- ---
Peak current:
31 A (200 VAC)
1,500 W 24 V 65 A (100 VAC) S8VM-15224C --- --- --- --- ---
(See note 70 A (200 VAC) (See note 3.)
4.) Peak current:
105 A (200 VAC)
Note: 1. No outputs are built into these models.
2. The output capacity of the S8VM-15005@@ is 135 W.
3. M8 bolts and nuts for the output terminals are not included with the S8VM-15224C.
4. The 300-, 600-, and 1,500-W models have fans.
5. To perform front mounting using the bottom mounting models, use the Mounting Brackets (S82Y-VM@@F, sold separately).
2 Switch Mode Power Supply S8VM