New Product Noise Filter S8V-NF (Single-phase 250 V 3 A / 6 A Type) DIN Rail Mounting Type Ideal for Control Panels Featuring a Slim Design that Saves Space Push-In Connections for Safe and Easy Wiring 150 kHz to 1 MHz high attenuation Operation possible at ambient temperatures from -40 to 85C Complies with RoHS directives Certification for 3,000 m altitude (UL/EN 60939) Five years Warranty *1 *1. Refer to Period and Terms of Warranty on page 9 for details. Refer to Safety Precautions on page 6. Model Number Structure Model Number Legend Note: Not all combinations are possible. Refer to List of Model number in Ordering Information, below. S8V-NF S 2 132 1. Input type 2. Rated voltage 3. Rated current S: Single-phase AC/DC 2: 250 VAC/250 VDC 03: 3 A 06: 6 A Ordering Information Note: For details on normal stock models, contact your nearest OMRON representative. Rated voltage Rated current Model number 3 A S8V-NFS203 250 VAC 250 VDC 6 A S8V-NFS206 1S8V-NF Ratings and Characteristics Item Rated current 3 A 6 A Rated voltage Single-phase 250 VAC 50/60 Hz *1, 250 VDC Leakage current 1.0 mA max. (250 VAC/60 Hz) DC resistance 110 m max. I/O Attenuation 25 dB min. (Common Mode: 0.1 to 10 MHz, Normal Mode: 0.2 to 30 MHz) characteristics Withstand voltage 2.5 kVAC for 1 min. (between line and ground), current cutoff 10 mA Insulation resistance 100 M min. (500 VDC, 1 min.) Ambient operating temperature -40 to 85C (Derating is required. Refer to Engineering Data) (with no condensation or icing) Derating start temperature+85C +60C Storage temperature -40 to 85C (with no condensation or icing) Environment Ambient operating humidity 95% (Storage humidity: 95% max.) Vibration resistance 10 to 55 Hz, maximum 5 G, 0.42 mm half amplitude for 2 h each in X, Y, and Z directions 2 Shock resistance 150 m/s , 3 times each in X, Y, Z directions Weight 140 g max. Construction Degree of protection IP20 by EN/IEC 60529 UL 60939 (Recognition) OVC III (3000 m) Pol2 CSA C22.2 No.8 Standards Safety standards EN 60939 OVC III (3000 m) Pol2 ENEC *2 EAC (TR CU 004 / 2011) *1. If the input is connected to a UPS, do not connect a UPS with a square-wave output. Doing so will cause the internal temperature of the product to increase, possibly causing smoking or damage. *2. ENEC is a certification that makes product distribution to EU member countries, EFTA (European Free Trade Association) member countries, and Eastern European countries possible. Connections Circuit Diagram S8V-NFS203 L1 L1 S8V-NFS206 L(+) L(+) L2 L2 LINE LOAD N1 N1 N() N() N2 N2 NC Construction and Nomenclature Nomenclature S8V-NFS203, S8V-NFS206 No. Terminal name Name Function 1L1 2L2 Line terminals Connect the input lines to these terminals. *1 3N1 4N2 5 NC No connection Do not wire. 6L1 7L2 Connect the output lines to these terminals. Load terminals *1 8N1 9N2 10 PE Protective Earth terminal (PE) Connect the ground line to this terminal. *2 *1. Wiring is generally laid out so that the line terminal is connected to the input side and the load terminal is connected to the output side, though use in the opposite direction is also possible. Note that if the input and output are wired in reverse, the appropriate attenuation characteristics may not be obtained. *2. This is the protective earth terminal specified in the safety standards. Always ground this terminal. 2