Three-phase Input Switch Mode Power Supply S8VT DIN-rail mounting, Power Supply with a range of 5 A to 40 A output current 3 phase 400 to 500 VAC 5, 10, 20 and 40 A 24 VDC output Higher stability, lower ripple and noise level Compact design Fuses protection included Natural ventilation UL60950 (CSA22.2-60950), UL508 listing in addition to the CE mark Conform to EN61000-3-2 Parallel & serial operation possible Ordering Information S8VT Input voltage Power rating Output voltage Output current Model number 400 to 500 VAC 120 W 24 V 5 A S8VT-F12024E 3-phase 240 W 24 V 10 A S8VT-F24024E 480 W 24 V 20 A S8VT-F48024E 960 W 24 V 40 A S8VT-F96024E Model Number Legend S8VT - E 1 2 3 1. Input Voltage 2. Power Rating 3. Output Voltage F: 400 to 500 VAC 3-phase 120: 120 W 24: 24 V 240: 240 W 480: 480 W 960: 960 W Three-phase Input Switch Mode Power Supply S8VT 1Specifications Item Nominal Input Voltage F: 400 to 500 VAC Nominal Input Current 5 A 10 A 20 A 40 A Efficiency (400 VAC FULL LOAD) 86% 90% 91% 91% Input Voltage range 340 to 576 V 3AC resp. 480 to 810 VDC Frequency 50 to 60 Hz Current (max.) 0.5A 1A 1.5A 3A (Vin = Range min., Pmax) Power factor (400 VAC FULL 0.66 0.66 0.86 0.86 LOAD) Leakage current (max.) <3.5mA <3.5mA <3.5mA <3.5mA Inrush current (max.) < 30A Vin max. < 30A Vin max. < 40A Vin max. < 30A Vin max. (Pmax) EMI filter 210 mH 227 mH 26.8 mH 22.2 mH Line fuses T2A T3.15A T4A T6.3A Output Voltage adjustment range 21.6 to 28.0 VDC min. Tolerance adjustment accuracy 1% Ripple & noise (Pmax.) 100 mV max. (p.p. 0-20 MHz) Load variation influence 0.5% max. Input variation influence 0.25% max. Temperature variation influ- Less than 0.05%/C ence Startup time (max.) 1.3 s 1.3 s 1.3 s 1.3 s Hold time (min.) 15 ms 15 ms 15 ms 15 ms (Vin = 400 VAC) Protection - Short circuit protection continuative - Over load protection - Over voltage protection Parallel operation Yes (for two units) Serial operation Yes (for two units) Indicator Yes (Green LED) Others Heat radiation Natural air cooling Ambient temperature -10 to 70C (de-rating: 5%/C for 60 to 70C) Temperature power derating 60 to 70C see diagram Storage temperature -40 to 85C Ambient humidity 10 to 90% noncondensing Dielectric strength 2.5 kVAC Input-PE (for 1 sec. routine test) 3 kVAC Input-Output on isolation components (transformers) (for 1 sec. high-pot routine test) 1 kVAC Output-PE (for 1 sec. routine test). Insulation resistance 500 Mohm min at 500 VDC, Output - P.E. Vibration resistance 10 to 55 Hz, 0.375 mm single amplitude for 2 h each in X, Y and Z directions 10 to 150 Hz, 0.35 mm single amplitude for 80 min each in-X, Y and Z directions Shock resistance 150 m/s, 3 times each in X, Y, Z directions EMC EN55011 (EN55022) EN61000-3-2, EN61000-4-2, EN61000-4-3,EN61000-4-4,EN61000-4-5, EN61000-4-6,EN61000-4-8,EN61000-4-11, EN61204-3 *1 Approval standards IEC60950-1, EN60950-1 UL60950-1, CSA 22.2 No. 60950-1, UL508 Listed , EN50178, EN60204 (AC and DC input) Life expectancy 10 years (Vin=400-500 VAC 50% of rated output current Ta=40C) Weight 0.71 kg 0.91 kg 1.8 kg 3.3 kg *1 For the 5 A and 10 A models UL is pending 2 Three-phase Input Switch Mode Power Supply S8VT