Motor Protective Relay SE CSM SE DS E 6 1 Solid-state Relay Provides Three Operating Functions in a Compact Package Prevents burnouts in 3-phase induction motors due to overcur- rent, open-phase, or reverse-phase. LEDs indicate operation of the selected operating function. Wide setting ranges: current: 1 to 160 A operating time: 1 to 40 s. Protects the motor from reversing without starting it. The SE cannot be used with circuits with distorted waveforms, inverter circuits, or capacitor loads. Model Number Structure Model Number Legend SE-K N 12 3 4 5 6 7 8 1. Basic model name 5. Control voltage SE: Motor Protective Relay 1: 100/110/120 VAC 2. Protective functions 2: 200/220/240 VAC K: Three possible operating functions: overcurrent, open- 4: 380/400/440 VAC phase, or reverse-phase protection 6. Reset method 3. Operating time characteristics for overload element None: Manual reset Q: Instantaneous type: Fixed time at starting and instanta- A: Automatic reset neous during operation 7. Operating value None:Inverse type: Inverse operation both at starting and during None: 115% of the current SV operation E: 100% of the current SV 4. Case 8. Product history P: Plug-in type N: New version None: Flush mount type Note: A 3-phase transformer (sold separately) must be used to operate Plug-in Relays at 380, 400, 415, or 440 VAC. Drop the primary voltage (380 to 440 VAC) to a 200-VAC secondary voltage before applying it to the SE-KP2EN or SE-KQP2EN. Ordering Information SE- EN Overcurrent operating value: 100% of the current SV. Terminal/mounting Control voltage Reset Model Inverse type Instantaneous type (See note.) Plug-in terminal/DIN 100/110/120 VAC Manual SE-KP1EN SE-KQP1EN rail via socket 200/220/240 VAC SE-KP2EN SE-KQP2EN Screw terminal/flush 100/110/120 VAC SE-K1EN SE-KQ1EN mount 200/220/240 VAC SE-K2EN SE-KQ2EN 380/400/440 VAC SE-K4EN SE-KQ4EN Note: With start-up lock: fixed time-limit on start-up, instantaneous thereafter. Plug-in type requires a socket (8PFA1) which is sold separately. 1SE SE- N Overcurrent operating value: 115% of current SV. Control voltage Reset Model Inverse type Instantaneous type (See note 1.) 100/110 120 VAC Manual SE-KP1N SE-KQP1N Automatic SE-KP1AN SE-KQP1AN 200/220/240 VAC Manual SE-KP2N SE-KQP2N Automatic SE-KP2AN SE-KQP2AN 100/110/120 VAC Manual SE-K1N SE-KQ1N Automatic SE-K1AN SE-KQ1AN 200/220/240 VAC Manual SE-K2N SE-KQ2N Automatic SE-K2AN SE-KQ2AN 380/400/440 VAC Manual SE-K4N SE-KQ4N Automatic --- --- Note: 1. With start-up lock: fixed time-limit on start-up, instantaneous thereafter. 2. The operating value for the overload detection function of the SE- N is 115% of the current SV. Accessories (Order Separately) Current Converters 3-phase Transformer Specify the primary voltage when ordering. Model Current range Only one SE relay can be connected. SET-3A 1 to 80 A SET-3B 64 to 160 A Model Voltage specification Secondary power consumption DIN rail socket SE-PT400 Primary side 380 to 480 V 7VA (wide power 8PFA1 supply range) Secondary side 190 to 240 V (wide power supply range) Adapter Model SE-F7AD This Adapter is used to replace existing flush mount models with new models. Specifications Ratings Motor circuit Voltage: 500 VAC max. 3-phase (primary voltage at SET current converter) Current: 1 to 80 A or 64 to 160 A 3-phase (primary current at SET current converter) Power supply circuit Voltage: 100/110/120 VAC, 200/220/240 VAC, or 380/400/440 VAC 3-phase (treat as a single phase voltage when the reverse-phase function is not needed) Voltage fluctuation: +10/15% max. of the rated voltage (+10/50% max. for open-phase function) Frequency: 50/60 Hz 5% Current SV range See table of Current Converter. Output relay contact Configuration: SPDT Capacity: Refer to the table below. Power consumption 100/110/120 VAC: approx. 3.5 VA 200/220/240 VAC: approx. 7 VA 380/400/440 VAC: approx. 11 VA Plug-in model: Munsell 5Y7/1 Case color Panel-mount model: Munsell N1.5 Output Contact Capacity Control power supply Contact Manual reset Automatic reset 100/110/120 VAC or NO 3 A (cos = 1.0)/1.5 A (cos = 0.3 to 0.4) at 240 VAC 3 A (cos = 1.0)/2 A (cos = 0.4) at 240 VAC 200/220/240 VAC NC 3 A (cos = 1.0)/2 A (cos = 0.3 to 0.4) at 240 VAC 380/400/440 VAC NO 3 A (cos = 1.0)/1.5 A (cos = 0.3 to 0.4) at 440 VAC --- NC 3 A (cos = 1.0)/2 A (cos = 0.3 to 0.4) at 440 VAC 2