F502-EN2-04.book Seite 53 Dienstag, 26. Juli 2005 5:48 17 Standard Flat Inductive Proximity Sensors TL-W Front and side facing surface IP67 DC 2-wire and DC 3-wire models Ordering Information DC 2-wire Models Model Shape Sensing distance Output and operating status NO NC *1 *1 TL-W5MD1 TL-W5MD2 5mm *1. Models with different response frequency are available. These model numbers take the form TL-W5MD 5 (e.g., TL- W5MD15) DC 3-wire Models Model Output Shape Sensing distance Output and operating status specifications PNP-NO PNP-NC NPN-NO NPN-NC *1 TL-W1R5MB1 --- TL-W1R5MC1 --- 1.5mm *1 TL-W3MB1 TL-W3MB2 TL-W3MC1 TL-W3MC2 3mm DC 3-wire *1 TL-W5MB1 TL-W5MB2 TL-W5MC1 TL-W5MC2 5mm *1 *1 --- --- TL-W20ME1 TL-W20ME2 20mm Shielded DC 3-wire TL-W5F1 TL-W5F2 TL-W5E1 TL-W5E2 5mm *1. Models with different response frequency are available. These model numbers take the form TL-W5MD 5 (e.g., TL-W5MD15) TL-W D-53 TL-WF502-EN2-04.book Seite 54 Dienstag, 26. Juli 2005 5:48 17 Rating/Performance DC 2-wire Models Item Model TL-W5MD Sensing distance 5 mm 10% Setting distance 0 to 4 mm Differential distance 10% max. Sensing object Ferrous metal(Sensitivity decreases with non-ferrous metals) Standard sensing object Iron, 18 x 18 x 1 mm Response frequency 0.5 kHz Rated supply voltage 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max. (operating voltage) Leakage current 0.8 mA max. Switching capacity 3 to 100 mA Control output Residual voltage 3.3 V max. (under load current of 100 mA with cable length of 2 m) D1 models: Operation indicator (Red LED), Operation set indicator (Green LED) Indicator lamp D2 models: Operation indicator (Red LED) Operating status D1 models: NO (with sensing object approaching) D2 models: NC Protective circuits Surge absorber, short-circuit protection Ambient temperature Operating/Storage: -25C to 70C (with no icing or condensation) Ambient humidity Operating/Storage: 35% to 95%RH (with no condensation) Temperature influence 10% max. of sensing distance at 23C within a temperature range of -25C and 70C Voltage influence 2.5% max. of Sensing distance within a rated voltage range 15%. Insulation resistance 50 M min. (at 500 VDC) between energized parts and case Dielectric strength 1,000 VAC for 1 min between energized parts and case Vibration resistance 10 to 55 Hz, 1.5 mm double amplitude for 2 hours each in X, Y, and Z directions 2 Shock resistance Destruction: 500 m/s for 3 times each in X, Y, and Z directions Protective structure IEC60529 IP67 Connection method Pre-wired models (standard length: 2 m) Weight (Packed state) Approx. 45 g Case Material Heat-resistant ABS resin Sensing surface Accessories Instruction manual * The response frequencies for DC switching are average values measured under the condition that the distance between each sensing object is twice as large as the size of the sensing object and the sensing distance set is half of the maximum sensing distance. D-54 Inductive Sensors