Flat Inductive Proximity Sensor TL-W CSM TL-W DS E 12 3 Standard Flat Sensors in Many Different Variations Only 6 mm thick yet provides a sensing distance of 3 mm (TL-W3MC1). Aluminum die-cast models also available. For the most recent information on models that have been certified for Be sure to read Safety Precautions on safety standards, refer to your OMRON website. page 7. Ordering Information Sensors Refer to Dimensions on page 8. DC 2-Wire Models Model Appearance Sensing distance Operation mode NO NC Unshielded TL-W5MD1 2M *1 *2 TL-W5MD2 2M *2 5 mm DC 3-Wire Models Model Appearance Sensing distance Output configuration Operation mode NO NC *1 NPN TL-W1R5MC1 2M --- *2 1.5 mm PNP TL-W1R5MB1 2M --- *1 *1 NPN TL-W3MC1 2M TL-W3MC2 2M *2 *2 3 mm Unshielded PNP TL-W3MB1 2M *2 TL-W3MB2 2M *2 *1 NPN TL-W5MC1 2M TL-W5MC2 2M *2 5 mm PNP TL-W5MB1 2M TL-W5MB2 2M NPN TL-W20ME1 2M *1 TL-W20ME2 2M *1 20 mm NPN TL-W5E1 2M TL-W5E2 2M Shielded 5 mm PNP TL-W5F1 2M TL-W5F2 2M *1. Models with a different frequency are also available to prevent mutual interference. The model numbers are TL-W M 5 (e.g., TL-W5MD15). *2. Models are also available with robotics (bend resistant) cables. Add -R to the model number. (e.g., TL-W5MC1-R 2M) 1TL-W Mounting Bracket (Attachment) Order a Nut Set when required, e.g., if you lose the nuts. Model Applicable Sensors Quantity Y92E-D2R5 TL-W1R5 1 Y92E-D3 TL-W3 Ratings and Specifications DC 2-Wire Models Item Model TL-W5MD Sensing distance 5 mm 10% Set distance 0 to 4 mm Differential travel 10% max. of sensing distance Ferrous metal (The sensing distance decreases with non-ferrous metal. Refer to Engineering Data on page Detectable object 5.) Standard sensing object Iron, 18 18 1 mm Response frequency *1 500 Hz Power supply voltage 12 to 24 VDC (10 to 30 VDC), ripple (p-p): 10% max. (operating voltage range) Leakage current 0.8 mA max. Con- Load current 3 to 100 mA trol Residual voltage 3.3 V max. (under load current of 100 mA with cable length of 2 m) output D1 Models: Operation indicator (red), Setting indicator (green) Indicators D2 Models: Operation indicator (red) Operation mode (with sensing D1 Models: NO Refer to the timing charts under I/O Circuit Diagrams on page 5 for details. object approaching) D2 Models: NC Protection circuits Load short-circuit protection, Surge suppressor Ambient temperature range Operating/Storage: 25 to 70C (with no icing or condensation) *2 Ambient humidity range Operating/Storage: 35% to 95% (with no condensation) Temperature influence 10% max. of sensing distance at 23C in the temperature range of 25 to 70C Voltage influence 2.5% max. of sensing distance at rated voltage in the rated voltage 15% range Insulation resistance 50 M min. (at 500 VDC) between current-carrying parts and case Dielectric strength 1,000 VAC for 1 min between current-carrying parts and case Vibration resistance Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions 2 Shock resistance Destruction: 500 m/s 3 times each in X, Y, and Z directions Degree of protection IEC 60529 IP67, in-house standards: oil-resistant *2 Connection method Pre-wired Models (Standard cable length: 2 m) Weight (packed state) Approx. 80 g Case Materials Heat-resistant ABS Sensing surface Accessories Instruction manual *1. The response frequency is an average value. Measurement conditions are as follows: standard sensing object, a distance of twice the standard sensing object, and a set distance of half the sensing distance. *2. For environments that require oil resistance, the upper limit of the ambient operating temperature range is 40C. 2