Pushbutton Switch (Cylindrical 10.5-dia.) VAQ CSM VAQ DS E 4 4 Built-in V-series Miniature Basic Switch for Compatibility with Business and Consumer Equipment Momentary operation and lock. Operation Unit available in six colors. Improved sense of touch with bu ilt-in miniature basic switch. Refer to Safety Precautions for All Pushbutton Switches/ Indicators and Safety Precautions on page 4. Ordering Information Operation Unit color Classifica- Shape of Out- tion Operation Unit put Blue (-A) Black (-B) Green (-G) Red (-R) White (-W) Yellow (-Y) 1 *1 VAQ-4A-K VAQ-4B-K VAQ-4G-K VAQ-4R-K VAQ-4W-K VAQ-4Y-K Momentary 13 dia. 1 *2 VAQ-4A-L VAQ-4B-L VAQ-4G-L VAQ-4R-L VAQ-4W-L VAQ-4Y-L operation 2 *2 2VAQ-4A 2VAQ-4B 2VAQ-4G 2VAQ-4R 2VAQ-4W 2VAQ-4Y 11.4 Lock 1 *2 VAQR-4A VAQR-4B VAQR-4G VAQR-4R VAQR-4W *2 *1. The Operation Unit can be inserted and removed. *2. The Operation Unit is screwed in. Specifications Ratings Non-inductive load (A) Inductive load (A) Item Rated Resistive Inductive voltage (V) Lamp load Motor load Built-in Switch load load 125 VAC 15 2 10 3 250 VAC 15 2 10 3 8 VDC 15 4 10 6 V-15-1A5 30 VDC 10 4 10 4 125 VDC 0.6 0.1 0.6 0.1 250 VDC 0.3 0.05 0.3 0.05 Note: 1. The above values are for steady-state currents. 2. Inductive load: Power factor = 0.4 (AC) time constant = 7 ms (DC). 3. The lamp load has an inrush current of 10 times the steady-state current. 4. The motor load has an inrush current of 6 times the steady-state current. 5. The rated values above are for testing conducted under the following conditions. (1) Ambient temperature: 20 2C. (2) Ambient humidity: 65% 5%RH (3) Operating frequency: 20 times/min. 1VAQ Specifications Characteristics Operating Characteristics Mechanical 120 operations/min Operating Output 1 2 frequency Electrical 20 operations/min Operating characteristics Insulation resistance 100 M min. (at 500 VDC) Operating force OF max. 1.96 N 4.90 N Contact resistance 30 m max. (initial value) Releasing force RF min. 0.39 N 0.78 N Between terminals of 1,000 VAC, 50/60 Hz for 1 Pretravel PT max. 1.3 mm 1.6 mm same polarity minute Between current- Contact Form Dielectric carrying metal part and strength Name Contact form ground, and between 1,500 VAC, 50/60 Hz for 1 each terminal and non- minute current-carrying metal part Double-throw contacts NC Vibration 10 to 55 Hz, 1.5 mm Malfunction NO resistance double amplitude * 2 COM Destruction 500 m/s max. Shock resistance 2 Malfunction 200 m/s max. * Approved Standard Ratings Mechanical 3,000,000 operations min. Durability The built-in V-15-1A5 Switch is approved for UL and CSA. Electrical 100,000 operations min. Weight Approx. 12 to 40 g NC 36 A max. Inrush current NO 36 A max. 25 to 80C (with no icing or Ambient operating temperature condensation) Ambient operating humidity 35% to 85%RH 25 to 80C (with no icing or Ambient storage temperature condensation) Degree of protection IP00 Electric shock protection class Class II PTI (proof tracking index) 175 Pollution degree 3 (IEC947-5-1) * Malfunction within 1 ms Insert one of the following letters into the box ( ) in the model number. Refer to Ordering Information for color symbols. Dimensions (Unit: mm) VAQ-4 -K 3 16 tapping screw *4 18 11 5.6 dia. 6 dia. Width across hexagonal nut flats: 14, *2 *3 Thickness: 2. 15 dia. (lock washer) Face nut thickness: 2, Diameter: 14. *1 One, M10 38 22.2 28 13 dia. 7 Note: The Operation Unit can be 11.4 8.6 10.3 *1. Unthreaded screw section: Approx. one thread 10 inserted and removed. 3 *2. Thermoplastic resin foam 21.9 FP: 24.5 max. *3. V-15-1A5 Miniature Basic Switch 25 *4. Three, 187 tab/solder terminals (t = 0.5) 2