General-purpose Basic Switch X Direct Current Switch with Built-in Magnetic Blowout Incorporates a small permanent magnet in the contact mechanism to deflect the arc to effectively extinguish it. Ideal for switching DC circuits Wide variety of actuators for a wide scope of applications Same shape and mounting procedures as Omrons Model Z snap action switches. Ordering Information Solder Screw Solder Screw Terminal Terminal terminal terminal terminal terminal Actuator Model Model Actuator Model Model Pin plunger X-10G X-10G-B Hinge lever X-10GW X-10GW-B Slim spring plunger X-10GS X-10GS-B Low-force hinge lever X-10GW4 X-10GW4-B Short hinge roller Short spring plunger X-10GD X-10GD-B X-10GW22 X-10GW22-B lever Panel mount plunger X-10GQ X-10GQ-B Hinge roller lever X-10GW2 X-10GW2-B Panel mount roller Reverse hinge lever X-10GM X-10GM-B X-10GQ22 X-10GQ22-B plunger Reverse short hinge Panel mount cross X-10GM22 X-10GM22-B X-10GQ21 X-10GQ21-B roller lever * roller plunger Reverse hinge roller X-10GM2 X-10GM2-B Leaf spring X-10GL X-10GL-B lever * * The plungers of reverse-type models are continuously pressed by the Short hinge lever X-10GW21 X-10GW21-B compression coil springs and the plungers are freed by operating the levers. Model Number Legend X - 10 G - 3. Actuator 4. Terminals 1. Ratings 1 2 3 4 None: Solder terminal 10: 10 A (125 VDC) None: Pin plunger B: Screw terminal D: Short spring plunger (with toothed washer) S: Slim spring plunger 2. Contact Gap Q: Panel mount plunger G: 0.9 mm Q21: Panel mount cross roller plunger Q22: Panel mount roller plunger L: Leaf spring W: Hinge lever W2: Hinge roller lever W21: Short hinge lever W22: Short hinge roller lever W4: Low-force hinge lever M: Reverse hinge lever M2: Reverse hinge roller lever M22: Reverse short hinge roller lever General-purpose Basic Switch X 141Specifications Characteristics Operating speed 0.1 mm to 1 m/s (See note 1) Operating frequency Mechanical 240 operations/min Electrical 20 operations/min Contact resistance 15 m max. (initial value) Insulation resistance 100 M min. (at 500 VDC) Dielectric strength 1,500 VAC, 50/60 Hz for 1 min between terminals of the same polarity, between current-carrying metal parts and the ground, and between each terminal and non-current-carrying metal parts Vibration resistance Malfunction 10 to 55 Hz, 1.5-mm double amplitude (See note 2) 2 Shock resistance Destruction 1,000 m/s max. 2 Malfunction 300 m/s max. (See notes 1 and 2) Degree of protection IP00 Degree of protection against electric shock Class I Proof tracking index (PTI) 175 Ambient operating temperature 25C to 80C (with no icing) Ambient operating humidity 35% to 85%RH Service life Mechanical 1,000,000 operations min. Electrical 100,000 operations min. Weight Approx. 27 to 63 g Note: 1. The values are for the pin plunger models. 2. Malfunction: 1 ms max. Ratings Non-inductive load (A) Inductive load (A) Rated Resistive load Lamp load Inductive load Motor load voltage NC NO NC NO NC NO NC NO 8 VDC 10 3 1.5 10 10 5 2.5 14 VDC 10 3 1.5 10 10 5 2.5 30 VDC 10 3 1.5 10 10 5 2.5 125 VDC 10 3 1.5 7.5 6 5 2.5 250 VDC 3 1.5 0.75 2 1.5 2 1.5 Note: 1. The above values are for the steady-state current. 5. The above electrical ratings also apply to the AC voltage. 2. Inductive load has a power factor of 0.4 min. (AC) and a time 6. With the reverse-type models (X-10GM ), the normally constant of 7 ms max. (DC). closed circuits and normally open circuits are reversed. 3. Lamp load has an inrush current of 10 times the steady- 7. The ratings values apply under the following test conditions: state current. (1) Ambient temperature: 202C (2) Ambient humidity: 655%RH 4. Motor load has an inrush current of 6 times the steady-state (3) Operating frequency: 20 operations/min current. Contact Specification Safety Standards Ratings UL/CSA Material Silver Contacts Gap (standard value) 0.9 mm Rated voltage X-10G NC 30 A max. Inrush current 125 VDC 10 A NO 15 A max. 250 VDC 3 A EN (CE) (Conform to EN61058-1) Rated voltage X-10 125 VDC 10 A 142 General-purpose Basic Switch X