General-purpose Basic Switch X CSM X DS E 4 3 Direct Current Switch with Built-in Magnetic Blowout Incorporates a small permanent magnet in the contact mechanism to deflect the arc to effectively extinguish it. Same shape and mounting procedures as the Z Basic Switches. Be sure to read Safety Precautions on page 9 and Safety Precautions for All Basic Switches. For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Model Number Structure Ordering Information Model Number Legend Terminal Solder terminal Screw terminal Actuator Model Model X-10G - (1) (2)(3) (4) Pin plunger X-10G X-10G-B (1) Ratings Slim spring plunger X-10GS X-10GS-B 10 : 10 A (125 VDC) (2) Contact Gap Short spring plunger X-10GD X-10GD-B G : 0.9 mm Panel mount plunger X-10GQ X-10GQ-B (3) Actuator None : Pin plunger D : Short spring plunger Panel mount roller plunger X-10GQ22 X-10GQ22-B S : Slim spring plunger Panel mount cross Q : Panel mount plunger X-10GQ21 X-10GQ21-B roller plunger Q21 : Panel mount cross roller plunger Q22 : Panel mount roller plunger X-10GL X-10GL-B Leaf spring L : Leaf spring W : Hinge lever Short hinge lever X-10GW21 X-10GW21-B W2 : Hinge roller lever W21 : Short hinge lever W22 : Short hinge roller lever Hinge lever X-10GW X-10GW-B W4 : Low-force hinge lever M : Reverse hinge lever X-10GW4 X-10GW4-B Low-force hinge lever M2 : Reverse hinge roller lever M22 : Reverse short hinge roller lever Short hinge roller lever X-10GW22 X-10GW22-B (4) Terminals None : Solder terminal Hinge roller lever X-10GW2 X-10GW2-B B : Screw terminal (with toothed washer) X-10GM X-10GM-B Reverse hinge lever Reverse short hinge X-10GM22 X-10GM22-B roller lever * Reverse hinge roller lever * X-10GM2 X-10GM2-B * The plungers of reverse-type models are continuously pressed by the compression coil springs and the plungers are freed by operating the levers. 1X Specifications Ratings Contact Specification Non-inductive load (A) Inductive load (A) Material Silver Contacts Rated Resistive Inductive Gap Lamp load Motor load 0.9 mm voltage load load (standard value) NC NO NC NO NC NO NC NO NC 30 A max. Inrush current 8 VDC 10 3 1.5 10 10 5 2.5 NO 15 A max. 14 VDC 10 3 1.5 10 10 5 2.5 30 VDC 10 3 1.5 10 10 5 2.5 Engineering Data 125 VDC 10 3 1.5 7.5 6 5 2.5 Mechanical Durability (X-10G) 250 VDC 3 1.5 0.75 2 1.5 2 1.5 5,000 Note: 1. The above values are for the steady-state current. Ambient temperature: 202C 3,000 2. Inductive load has a power factor of 0.4 min. (AC) and a time constant Ambient humidity: 655%RH of 7 ms max. (DC). Without load Operating frequency: 240 operations/min 3. Lamp load has an inrush current of 10 times the steady-state current. 1,000 4. Motor load has an inrush current of 6 times the steady-state current. 700 5. The above electrical ratings also apply to the AC voltage. 500 6. With the reverse-type models (X-10GM ), the normally closed circuits and normally open circuits are reversed. 300 7. The ratings values apply under the following test conditions: 200 (1) Ambient temperature: 202C (2) Ambient humidity: 655%RH 100 (3) Operating frequency: 20 operations/min 70 50 Certified Standard Ratings 30 20 Ask your OMRON representative for information on certified models. UL/CSA 10 0 0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 Rated voltage Model X-10G Overtravel (mm) 125 VDC 10 A Electrical Durability (X-10G) 250 VDC 3 A 500 Ambient temperature: 202C EN (CE) (Conform to EN61058-1) 300 Ambient humidity: 655%RH 200 Operating frequency: 20 operations/min Rated voltage Model X-10 125 VDC 10 A 100 70 50 Characteristics 125 VDC L/R = 0 30 Operating speed 0.1 mm to 1 m/s *1 20 Mechanical 240 operations/min 125 VDC Operating L/R = 7 ms frequency Electrical 20 operations/min 10 7 Insulation resistance 100 M min. (at 500 VDC) 5 Contact resistance 15 m max. (initial value) 3 1,500 VAC, 50/60 Hz for 1 min between 2 terminals of the same polarity, between Dielectric strength current-carrying metal parts and the ground, 1 02148610124 and between each terminal and non-current- Switching current (A) carrying metal parts Vibration Malfunction 10 to 55 Hz, 1.5-mm double amplitude *2 resistance 2 Destruction 1,000 m/s max. Shock 2 resistance Malfunction 300 m/s max. *1 *2 Mechanical 1,000,000 operations min. Durability Electrical 100,000 operations min. Degree of protection IP00 Degree of protection Class I against electric shock Proof tracking index (PTI) 175 Ambient operating 25C to 80C (with no icing) temperature Ambient operating 35% to 85%RH humidity Weight Approx. 27 to 63 g *1. The values are for the pin plunger models. (Contact your OMRON representative for other models.) *2. Malfunction: 1 ms max. Structure Contact Form (SPDT) (+) COM NC NO Note: With the reverse-type models (X-10GM ), the NC and NO terminal arrangements are reversed. 2 4 4 Durability (x10 operations) Durability (x10 operations)