Solid-state Timer H3CA CSM H3CA DS E 2 1 DIN-sized (48 x 48, 45 x 75 mm) Timer with Digital Setting and LCD Display Dual power supplies for free AC/DC. Eight operation modes selectable with one unit. Any desired time can be set digitally within a range from 0.1 seconds to 9,990 hrs. Four external signal inputs. ON/OFF indicator for control output and bar indicator for remaining time. Conforms to UL, CSA, and CE marking. Ordering Information Operation/resetting Operation mode Terminal Time-limit Instantaneous Mounting system contact contact Surface Flush mounting mounting/ track mounting Time-limit operation/self- 8 operation modes 11-pin round socket SPDT --- H3CA-A H3CA-A resetting/external (selectable) Front screw H3CA-FA --- resetting (see note 2) (see note 3) Time-limit operation/ ON-delay operation 8-pin round socket DPDT --- H3CA-8 H3CA-8 self-resetting SPDT SPDT H3CA-8H H3CA-8H Note: 1. Specify both the model number and supply voltage when ordering for the H3CA-8H and H3CA-8. 2. The operation/resetting system depends on the selected operation mode. For details, see Timing Chart. 3. The 8 operation modes are as follows: A: ON-delay operation E: Interval operation B: Repeat cycle operation F: One-shot and flicker operation C: Signal ON/OFF-delay operation (1) G: Signal ON/OFF-delay operation (2) D: Signal OFF-delay operation (1) H: Signal OFF-delay operation (2) Accessories (Order Separately) Timer Track mounted socket Back connecting socket (See note.) Solder terminal Screw terminal H3CA-A P2CF-11 PL11 P3GA-11 H3CA-8H/H3CA-8 P2CF-08 PL08 P3G-08 Note: Track mounted socket can be used as a front connecting socket. Specifications Time Ranges A desired time can be set within a range of 0.1 s to 9,990 hrs by combining the three thumbwheel switch modules for time setting and one module for time unit selection. Time unit 0.1 s 1 s 0.1 min 1 min 0.1 hrs 1 hr 10 hrs Time range 1 to 999 (3 digits) 1H3CA Ratings Item H3CA-A/H3CA-FA H3CA-8 H3CA-8H Rated supply voltage 24 to 240 VAC (50/60 Hz), 100/110/120, 200/220/240 VAC, (50/60 Hz), (See note 2.) 12 to 240 VDC (permissible ripple: 24 VDC, 110 VDC (permissible ripple: 20% max.) (See note 1.) 20% max.) Operating voltage range 90% to 110% of rated supply voltage 85% to 110% of rated supply voltage Power consumption AC: approx. 4 VA AC: approx. 10 VA/1 W AC: approx. 10 VA/1.5 W DC: approx. 2 W DC: approx. 1 W DC: approx. 2 W Control outputs 3 A at 250 VAC, resistive load (cos = 1) Note: 1. Single-phase, full-wave rectified power sources may be used for 24 to 240 VDC. 2. Refer to Safety Precautions for All Times when combining the Timer with an AC 2-wire proximity sensor. Characteristics Accuracy of operating 0.3% 0.05 s time Influence of voltage Influence of temperature Setting error 0.5% 0.05 s max. Reset time H3CA-A/-FA: 0.5 s max. H3CA-8H/-8: 0.1 s max. Insulation resistance 100 M min. (at 500 VDC) Dielectric strength 2,000 VAC, 50/60 Hz for 1 min (between current-carrying and non-current-carrying parts and between contact and control circuit) 1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts) Impulse withstand 3 kV voltage Vibration resistance Destruction: 10 to 55 Hz with 0.75-mm double amplitude for 1 h each in three directions Malfunction: 10 to 55 Hz with 0.5-mm double amplitude for 10 min each in three directions 2 Shock resistance Destruction: 980 m/s 2 Malfunction: 98 m/s Ambient temperature Operating: 10C to 55C Ambient humidity Operating: 35% to 85% Life expectancy Mechanical: 10,000,000 operations min. (under no load at 1,800 operations/h) Electrical: 100,000 operations min. (3 A at 250 VAC, cos = 1 at 1,800 operations/h) See Lift-test Curve for more details. Approved standards UL508, CSA C22.2 No. 14, LR, NK Conforms to EN61010-1. EMC (EMI) EN61326 Emission Enclosure: EN55011 Group 1 class A Emission AC mains: EN55011 Group 1 class A (EMS) EN61326 Immunity ESD: EN61000-4-2: 4 kV contact discharge (level 2) 8 kV air discharge (level 3) Immunity RF-interference: EN61000-4-3: 10 V/m (Amplitude-modulated, 80 MHz to 1 GHz) (level 3) 10 V/m (Pulse-modulated, 900 MHz 5 MHz) (level 3) Immunity Conducted Disturbance: EN61000-4-6: 10 V (0.15 to 80 MHz) (according to EN61000-6-2) Immunity Burst: EN61000-4-4: 2 kV power-line (level 3) 1 kV I/O signal-line (level 4) Immunity Surge: EN61000-4-5: 1 kV line to lines (power and output lines) (level 3) 2 kV line to ground (power and output lines) (level 3) Immunity Voltage Dip/Interruption EN61000-4-11: 0.5 cycle, 100% (rated voltage) Weight H3CA-A: approx. 110 g H3CA-FA: approx. 190 g 2