Daily Time Switch H5L CSM H5L DS E 2 1 Weekly Control with a Large Time Display Easy Programming with Large Display and Interactive Functions. Easy operation with five keys. Up to 24 steps of ON/OFF operations can be set. Power supply freely selectable from 100 to 240 VAC. 96 mm Memory protection during power failure for up to 10 years. Certified for UL and CSA safety standards. The same setting can be used for multiple-day operation and timer operation. 96 mm Refer to Safety Precautions for All Timers. Refer to Safety Precautions on page 12 Ordering Information Wiring Backup power supply function for memory No. of program steps Model protection Screw terminals Provided (approx. 10 years at 25C) 24 (Each ON or OFF is considered to be one step.) H5L-A Specifications Time Ranges Rated time Time setting range Time division 24 hrs x 7 days 00:00 to 23:59 1 min Ratings Rated supply voltage 100 to 240 VAC (50/60 Hz) Operating voltage range 85% to 110% of rated supply voltage Power consumption Approx. 4 VA at 240 VAC Control outputs 15 A at 250 VAC, resistive load at 50C 12 A at 250 VAC, resistive load at 55C Minimum applied load: 100 mA at 5 VDC (failure level: P, reference value) 1H5L Characteristics Accuracy of operating time 0.01% 0.05 s max. (see note 1) Setting error Influence of voltage Influence of temperature Time accuracy 15 s per month (at 25C) Insulation resistance 100 M min. Dielectric strength 2,000 VAC, 50/60 Hz for 1 min (between current-carrying terminals and exposed non-current-carrying metal parts and between control power supply circuit and contact control output circuits) 1,000 VAC, 50/60 Hz for 1 min (between non-continuous contacts) Vibration resistance Destruction: 10 to 55 Hz with 0.75-mm double amplitude Malfunction: 10 to 55 Hz with 0.5-mm double amplitude 2 Shock resistance Destruction: 300 m/s (approx. 30G) 2 Malfunction: 100 m/s (approx. 10G) Ambient temperature Operating: 10C to 55C Ambient humidity Operating: 35% to 85% Life expectancy 100,000 operations min. (15 A at 250 VAC, resistive load) Approved standards UL (File No. E52800), CSA (File No. LR22310) Weight Approx. 350 g Note: The overall error, which includes repeat accuracy, setting error, and variations due to changes in voltage and temperature, is 0.01% or 0.05 s max. The accuracy of 0.01% also indicates the error in the time interval of the set time. Engineering Data Ambient Operating Temperature and Carry Current Note that the upper limit of the ambient operating temperature lowers when a large carry current is being applies as shown below. Carry current AC/DC (A) 2 Upper limit of ambient temperature (C)