CSM G3NA DS E 9 2 CSM G3NA DS E 9 2 The reliable choice for Hockey-puck-style Solid State Relays. Available in a wide Range of Currents and Voltage. (5 to 90A, max 660 VAC) All models feature the same compact dimensions to provide a uniform mounting pitch. Operation indicator enables monitoring operation. Protective cover for greater safety. Built-in varistor effectively absorbs external surges. (except G3NA-D210B) Standard models certified by UL and CSA UTU models by also TV (except G3NA-420B, 610B, 625B, 650B) For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Refer to Safety Precautions for All Solid State Relays. Refer to Safety Precautions for All Solid State Relays. Model Number Structure Model Number Legend G3NA- - - 2 3 4 5 6 7 8 1 1. Basic Model Name 5. Terminal Type G3NA: Solid State Relay B: Screw terminals 2. Load Power Supply 6. Zero Cross Function Blank: AC output Blank: Equipped with zero cross function (AC-output models only) D: DC output 7. Certification 3. Rated Load Power Supply Voltage Blank: Standard models (certified by UL and CSA) 2: 200 VAC or 200 VDC UTU: Certified by UL, CSA, and TV 4: 400 VAC 8. RoHS Conformance 6: 600 VAC Blank, 2: RoHS conformance each type 4. Rated Load Current (All products are RoHS conformance) 05: 5 A 10: 10 A 20: 20 A 25: 25 A 40: 40 A 50: 50 A 75: 75 A 90: 90 A G3NA Solid State Relays 1Ordering Information List of Models Zero cross Applicable output load Isolation LED Indicator Rated input voltage Model function (See note 1) Phototriac Coupler 5 to 24 VDC G3NA-205B DC5-24 5 A at 24 to 240 VAC 100 to 120 VAC G3NA-205B AC100-120 (See note 2.) Photocoupler 200 to 240 VAC G3NA-205B AC200-240 Phototriac Coupler 5 to 24 VDC G3NA-210B DC5-24 10 A at 24 to 240 VAC 100 to 120 VAC G3NA-210B AC100-120 (See note 2.) Photocoupler 200 to 240 VAC G3NA-210B AC200-240 Phototriac Coupler 5 to 24 VDC G3NA-220B DC5-24 20 A at 24 to 240 VAC 100 to 120 VAC G3NA-220B AC100-120 (See note 2.) Photocoupler 200 to 240 VAC G3NA-220B AC200-240 Phototriac Coupler 5 to 24 VDC G3NA-225B DC5-24 25 A at 24 to 240 VAC (See note 2.) 100 to 120 VAC G3NA-225B AC100-120 Photocoupler 200 to 240 VAC G3NA-225B AC200-240 Phototriac Coupler 5 to 24 VDC G3NA-240B DC5-24 40 A at 24 to 240 VAC (See note 2.) 100 to 120 VAC G3NA-240B AC100-120 Photocoupler 200 to 240 VAC G3NA-240B AC200-240 Phototriac Coupler 5 to 24 VDC G3NA-250B-UTU DC5-24 50 A at 24 to 240 VAC 100 to 120 VAC G3NA-250B-UTU AC100-120 (See note 2.) Photocoupler 200 to 240 VAC G3NA-250B-UTU AC200-240 Phototriac Coupler 5 to 24 VDC G3NA-275B-UTU-2 DC5-24 75 A at 24 to 240 VAC (See note 2.) Photocoupler 100 to 240 VAC G3NA-275B-UTU-2 AC100-120 Phototriac Coupler 5 to 24 VDC G3NA-290B-UTU-2 DC5-24 90 A at 24 to 240 VAC Yes (See note 2.) 100 to 240 VAC G3NA-290B-UTU-2 AC100-120 Yes 5 to 24 VDC G3NA-410B DC5-24 10 A at 200 to 480 VAC 100 to 240 VAC G3NA-410B AC100-240 5 to 24 VDC G3NA-420B DC5-24 20 A at 200 to 480 VAC 100 to 240 VAC G3NA-420B AC100-240 5 to 24 VDC G3NA-425B-2 DC5-24 25 A at 200 to 480 VAC 100 to 240 VAC G3NA-425B-2 AC100-240 5 to 24 VDC G3NA-440B-2 DC5-24 40 A at 200 to 480 VAC 100 to 240 VAC G3NA-440B-2 AC100-240 5 to 24 VDC G3NA-450B-UTU-2 DC5-24 50 A at 200 to 480 VAC 100 to 240 VAC G3NA-450B-UTU-2 AC100-240 Photocoupler 5 to 24 VDC G3NA-475B-UTU-2 DC5-24 75 A at 200 to 480 VAC 100 to 240 VAC G3NA-475B-UTU-2 AC100-240 5 to 24 VDC G3NA-490B-UTU-2 DC5-24 90 A at 200 to 480 VAC 100 to 240 VAC G3NA-490B-UTU-2 AC100-240 5 to 24 VDC G3NA-610B DC5-24 10 A at 400 to 600 VAC 100 to 240 VAC G3NA-610B AC100-240 5 to 24 VDC G3NA-625B DC5-24 25 A at 400 to 600 VAC 100 to 240 VAC G3NA-625B AC100-240 5 to 24 VDC G3NA-650B DC5-24 50 A at 400 to 600 VAC 100 to 240 VAC G3NA-650B AC100-240 5 to 24 VDC G3NA-D210B DC5-24 10 A at 5 to 200 VDC 100 to 240 VAC G3NA-D210B AC100-240 * The standard models are certified by UL and CSA. To order a TV-certified model, add -UTU to the model number as shown below: Example: G3NA-210B-UTU DC5-24. Note: 1. The applicable load is the value for when the SSR is used with silicon grease applied to the specified heat sink. The applicable load depends on the ambient temperature. Refer to Load Current vs. Ambient Temperature in Engineering Data on page 6. 2. Loss time increases under 75 VAC. (Refer to page 18.) Confirm operation with the actual load. 2 G3NA Solid State Relays