Temperature Controller E5CS-X 1/16 DIN Sized Controller Offers Selectable Control, Alarm Modes Accurate to 0.5% of full scale Multiple temperature scale ranges allow flexibility to match application Field-selectable temperature ranges in F and C Selectable ON/OFF and PID control with auto-tuning of proportional band 8-function alarm, standard Tamper-proof setting, faulty sensor compensation and controller diagnostics Easy-to-read 11 mm high LED display Nonvolatile memory backup 3-year warranty Ordering Information TEMPERATURE CONTROLLERS Item Part number Sensor input type Thermocouple Platinum RTD (Pt: 100 , Interchangeable thermistor (Types J and K) DIN and JIS standards) (THE types) Output Contact E5CS-R1KJX-F E5CS-R1PX-F E5CS-R1GX-F Voltage E5CS-Q1KJX-F E5CS-Q1PX-F E5CS-Q1GX-F Temperature Ranges Thermocouple Input Type Input type Type K Type J Temperature range 0 to 200 0 to 300 0 to 400 0 to 500 0 to 600 0 to 999 0 to 999 0 to 200 0 to 300 0 to 400 0 t0 500 Scale indication C C C/F C/F C/F C/F F C C C/F C/F Unit of measure 1 C or F Platinum RTD Input Type Temperature range 50 to 50 0.0 to 50.0 20 to 80 0.0 to 99.9 0 to 200 0 to 300 0 to 400 0 to 600 0 to 800 Scale indication C C C C/F C/F C C/F F F Unit of measure 1 C or F 0.1 C or F 1 C or F 0.1 C or F 1 C or F Thermistor Input Type Temp. range 50 to 50 0 to 100 50 to 150 100 to 200 150 to 300 50 to 100 0 to 200 100 to 300 200 to 400 300 to 600 Scale indication C F Unit of measure 1 C or F 37E5CS-X E5CS-X ACCESSORIES (ORDER SEPARATELY) Description Part number Protective cover Hard plastic protects front panel against dust, dirt and water drops Y92A-48 Panel mounting adapter Replacement for one supplied with each unit Y92F-30 Specifications Part number E5CS- 1KJX E5CS- 1PX E5CS- 1GX Sensor input type Thermocouple Platinum RTD (Pt: 100 ) Thermistor Type J (IC) and Type K (CA) DIN or JIS standard (interchangeable type) Supply voltage 100 to 240 VAC, 50/60 Hz operates on 85 to 110% of rated voltage Power consumption Approx. 7 VA Control Contact Type SPDT relay output Max. load 3 A, 250 VAC (resistive load) Voltage Logic load 12 VDC, 20 mA with short-circuit protection Hysteresis 0.2% of full scale during ON/OFF control action Response Output 2 seconds for output to change time Display 2 seconds for displayed indication to change Service life Mechanical 10 million operation minimum with contact output Electrical 100,000 operations minimum with contact output Alarm output Type SPST-NO relay Max. load 1 A, 250 VAC (resistive load) Setting range Absolute value alarm: Same as control output setting range Others: 0 to full scale Setting accuracy Set value coincides with indicated value, so no relative error exists Indication accuracy 0.5% of full scale, 1 digit max. Display range 999 to 999 (limited to input type) Control Type ON/OFF and PID with automatic tuning of proportional band, switch selectable modes Proportional band 3% to 20% (in PID mode) automatically adjusted according to the rise time of the controlled system Reset time 4 minutes (in PID mode) Rate time 0.4 minutes (in PID mode) Proportional period 2 or 20 seconds, switch selectable Sampling period 500 ms Materials Plastic case Mounting Fits 1/16 DIN panel cutout includes panel mounting adapter Connections Screw terminals Weight 170 g (6 oz.) without mounting adapter Enclosure ratings Front panel IP50, NEMA 4 with optional Y92A-48N waterproof cover Rear panel IP30 Terminals IP00 Approvals UL Recognized, File Number E68481 CSA Certified, File Number LR59623 CE Conforms to EN61010-1 Ambient temperature Operating 10C to 55C (14F to 131F) Storage 25C to 65C (13F to 149F) Humidity 35 to 85% RH Insulation resistance 20 M minimum at 500 VDC Dielectric strength 2,000 VAC, 50/60 Hz for 1 minute between current-carrying terminals of different polarity Vibration Mechanical durability 10 to 55 Hz, 0.75 mm (0.03 in) double amplitude in X, Y, and Z directions for 2 hours each Malfunction durability 2 to 55 Hz, 2 G in X, Y, and Z directions for 10 minutes each 2 Shock Mechanical durability 30 m/s , in 6 directions, 3 times each 2 Malfunction durability 100 m/s , in 6 directions, 3 times each 38