Smart Sensors (High-precision Contact Type) ZX Series (ZX-T) For the most recent information on models that have been certified for safety standards, refer to your OMRON website. Ordering Information Sensors Sensor Heads Size Type Sensing distance Resolution (See note.) Model 6 dia. Short type 1 mm 0.1 m ZX-TDS01T Standard type 4 mm ZX-TDS04T Low measurement type ZX-TDS04T-L 8 dia. Standard type 10 mm 0.4 m ZX-TDS10T Ultra-low-load Type ZX-TDS10T-L Air Lift Type ZX-TDS10T-V Air Lift/Air Push Type ZX-TDS10T-VL Note:The resolution refers to the minimum value that can be read when a ZX-TDA 1 Amplifier Unit is connected. Amplifier Units Appearance Power supply Output type Model DC NPN ZX-TDA11 2M PNP ZX-TDA41 2M Accessories (Order Separately) Calculating Unit ZX-series Communications Interface Unit Appearance Model Appearance Model ZX-CAL2 ZX-SF11 ZX Series (ZX-T) Smart Sensors (High-precision Contact Type) 1 SmartMonitor Sensor Setup Tool for Cables with Connectors on Both Ends (for Personal Computer Connection Extension)* Appearance Name Model Cable length Model Quantity ZX-series Communi- ZX-SF11 1 m ZX-XC1A 1 cations Interface 4 m ZX-XC4A Unit 8 m ZX-XC8A * Robot Cable models are also available. The model numbers are ZX-XC R. ZX-series Communi- ZX-SFW11EV3 Preamplifier Mounting Brackets cations Interface *1, *2 Unit + ZX-series Appearance Model Remarks Sensor Setup Soft- ZX-XBT1 Attached to each + ware Basic Sensor Head CD-ROM CD-ROM ZX-series Sensor ZX-SW11EV3 Setup Software *1 ZX-XBT2 For DIN track mount- ing *1. When using the ZX-TDA11/41 with the SmartMonitor, either the ZX-SFW11EV3 or the ZX-SW11EV3 SmartMonitor must be used. Earlier versions cannot be used. *2. The ZX-SFW11EV3 SmartMonitor can be used only to set functions and monitor waveforms. Specifications Amplifier Units Item ZX-TDA11 ZX-TDA41 Measurement period 1 ms Possible average count set- 1, 16, 32, 64, 128, 256, 512, or 1,024 tings (See note 1.) Linear output (See note 2.) Current output: 4 to 20 mA/F.S., Max. load resistance: 300 Voltage output: 4 V (5 V, 1 to 5 V (See note 3.)), Output impedance: 100 Judgement outputs NPN open-collector outputs, 30 VDC, 30 mA max. PNP open-collector outputs, 30 VDC, 30 mA max. (3 outputs: HIGH/PASS/ Residual voltage: 1.2 V max. Residual voltage: 2 V max. LOW) Zero reset input, timing in- ON: Short-circuited with 0-V terminal or 1.5 V or less ON: Supply voltage short-circuited or supply voltage of put, reset input, judgement 1.5 V or less OFF: Open (leakage current: 0.1 mA max.) output hold input OFF: Open (leakage current: 0.1 mA max.) Function - Measurement value display - Present value/set value/output value display - Display reverse - ECO mode - Number of display digit changes - Sample hold - Peak hold - Bottom hold, peak-to-peak hold - Self-peak hold - Self-bottom hold - Zero reset - Initial reset - Direct threshold value setting - Position teaching - Hysteresis width setting - Timing inputs - Reset input - Judgement output hold input - (A-B) calculations (See note 4.) - (A+B) calculations (See note 4.) - Sensor disconnection detection - Zero reset memory - Function lock - Non-measurement setting - Clamp value setting - Scale inversion - Zero reset indicator - Span adjustment - Warming-up display - Pressing force alarm Indicators Judgement indicators: High (orange), pass (green), low (yellow), 7-segment main digital display (red), 7-segment sub-digital display (yellow), power ON (green), zero reset (green), enable (green) Power supply voltage 12 to 24 VDC 10%, Ripple (p-p): 10% max. Current consumption 140 mA max. (with Sensor connected), For 24-VDC power supply voltage: 140 mA max. (with Sensor connected) Ambient temperature Operating and storage: 0 to 50C (with no icing or condensation) Temperature characteristic 0.03% F.S./C Connection method Prewired (standard cable length: 2 m) Weight (packed state) Approx. 350 g Materials Case: PBT (polybutylene terephthalate), Cover: Polycarbonate Note 1. The response speed of the linear output is calculated as the measurement period (average count setting + 1). The response speed of the judgement outputs is calculated as the measurement period (average count setting + 1). 2. The output can be switched between a current output and voltage output using a switch on the bottom of the Amplifier Unit. 3. Setting is possible via the monitor focus function. 4. A Calculating Unit (ZX-CAL2) is required. 2 ZX Series (ZX-T) Smart Sensors (High-precision Contact Type)