AC-DC Power Supplies ALM150 Series 150 Watts Medical & IT Safety Approvals Energy Efficiency Level VI & EU CoC Tier 2 Compliant 4th Edition Medical EMC IP32 Environmental Rating Class I and Class II Versions <0.15 W Standby Power 0 C to 60 C Operation Low Earth Leakage Current 3 Year Warranty Dimensions: The ALM150 series of medical external power supplies is fully approved to international medical & ALM150: 7.323 x 2.843 x 1.496 (186.0 x 72.0 x 38.0 mm) IT safety standards. It has been designed with very high efficiency and low standby power, enabling it to meet the latest environmental legislation. The unit has a fully sealed enclosure complying with IP32 and a smooth surface finish making it easier to wipe down in a clinical setting. Models & Ratings (1,2,3) Output Power Output Voltage Output Current Total Regulation Model Number 12.0 V 12.5 A ALM150PS12 15.0 V 10.0 A ALM150PS15 150 W 19.0 V 7.9 A 5% ALM150PS19 24.0 V 6.2 A ALM150PS24 48.0 V 3.1 A ALM150PS48 Notes 1. For class II versions, add suffix C2-8 to the end of the part number e.g. 3. Power de-rated <100 VAC for 12 & 15 V models, refer to input specifications. ALM150PS24C2-8. 2. For optional input connector retention clip add suffix -A to the model number, e.g. ALM150PS24-A (not available for C2 versions) Mechanical Details 0.193 7.32 (186.0) 35.43 0.79 (900.0 20.0) (4.9) 1 1.41 0.079 (36.0 2.0) 4 Pin Power DIN 0.78 0.079 (20.0 2.0) 4 Pin Power DIN (KPPX-4P Equivalent ( Non-locking type) 2.83 Shell (72.0) 1.96 0.78 (50.0 20.0) AC Input IEC 320-C8 1.49 Pin Connection (38.0) 1 +Vout 2 +Vout 0.039 (1.0) 3.94 (100.3) 3 RTN 4 RTN AC Input Standard Models: 1.96 (50.0) IEC 320-C14 1.58 Shell Functional Earth (40.3) C2 Models: Floating 6.10 (155.0) Notes 1. All dimensions shown in inches (mm). Tolerance is 0.02 (0.5) maximum, except 4. For UK mains lead order part UK-MAINS-IEC for C14 versions, or UK-MAINS-8 output cable length. for C8 versions. 2. Weight: 1.4 lbs (635 g) approx. 5. For US mains lead order part US-MAINS-IEC for C14 versions, or US-MAINS-8 3. For European mains lead order part EU-MAINS-IEC for C14 versions, for C8 versions. or EU-MAINS-8 for C8 versions. 6. Output connector: 4 pin power din with pin 1 & 2 - positive and pin 3 & 4 - return, equivalent to KPPX-4P (non-locking). www.xppower.com 1AC-DC Power Supplies ALM150 Series Input Characteristic Minimum Typical Maximum Units Notes & Conditions 19, 24 & 48V models: Derate linearly from 100% load at 90 VAC to 80% load at 80 VAC, 300 VAC/5s maximum. Input Voltage 80 264 VAC 12 & 15 V models: Derate linearly from 100% load at 100 VAC to 80% load at 80 VAC, 300 VAC/5s maximum. Input Frequency 47 63 Hz Input Current 1.8/0.9 A Measured at 115/230 VAC Inrush Current 160 A 230 VAC, cold start at 25 C Power Factor >0.9 EN61000-3-2 Class A Earth Leakage Current 250 A 264 VAC, 60 Hz No Load Input Power 0.15 W Input Protection T3.15A/250 VAC internal fuse in both line & neutral Output Characteristic Minimum Typical Maximum Units Notes & Conditions Output Voltage 12 48 VDC See Models and Ratings table Initial Set Accuracy 2 % At 50% load Minimum Load No minimum load required Start Up Delay 12 s Start Up Rise Time 50 ms Hold Up Time 20 30 ms Full load and 115/230 VAC Line Regulation 0.5 % Total Regulation 5 % Maximum deviation, recovering to less than 1% within Transient Response 4% 500 s for 50-75-50% load change 20 MHz bandwidth, measured with 20 MHz Bandwidth and Ripple and Noise 1.5 % pk-pk 10 F electrolytic in parallel with 0.1 F ceramic capacitor. Overshoot 5 10 % At turn on / turn off Overload Protection 115 175 % Overvoltage Protection 150 % Recycle mains to reset Short Circuit Protection Trip and restart (hiccup), auto resetting Thermal Protection Measured internally, auto resetting Temperature Coefficient 0.02 %/C Patient Leakage Current 95 A 264 VAC, 60 Hz Environmental Characteristic Minimum Typical Maximum Units Notes & Conditions Operating Temperature 0 +60 C Derate from 100% load at 40 C to 30% load at 60 C Cooling Natural convection Operating Humidity 5 95 %RH Non-condensing Storage Temperature -25 +80 C Operating Altitude 5000 m Shock IEC68-2-27, 30 g, 11 ms half sine, 3 times in each of 6 axes Vibration IEC68-2-6, 10-500 Hz, 2 g 10 mins/sweep, 60 mins for each of 3 axes Derating Curve 100% 80% 60% 40% 20% 0 20 40 60 Ambient Temperature (C) www.xppower.com 2 Output Power (%)