CV (ACV) AUTOMOTIVE LOW PROFILE CV RELAYS (ACV) MICRO-ISO RELAY FEATURES TYPICAL APPLICATIONS Low prole: Headlights 22.5 mm(L)15 mm(W)15.7 mm(H) Magnetic clutches .886 inch(L).591 inch(W).618 inch(H) Radiator fans Low temperature rise Blowers Terminal temperature has been reduced Fog lamps Micro ISO Micro ISO compared with using our conventional Tail lights 1 Form C type 1 Form A type product Heaters Low sound pressure level Defoggers Noise level has been reduced Horns approx.10dB compared with using our Condenser fans, etc. conventional product. Wide line-up Micro ISO terminal types and resistor inside type. Plastic sealed type Plastically sealed for automatic cleaning. Compact and high-capacity 20A load switching N.O.: 20A 14V DC, N.C.: 10A 14V DC RoHS compliant (Max. carrying current: at 85C 185F) ORDERING INFORMATION ACV Contact arrangement 1: 1 Form C 3: 1 Form A Mounting classification 1: Micro ISO plug-in type Protective element 0: None (Standard type) 2: With resistor inside Coil voltage, DC 12: 12 V TYPES Contact arrangement Coil voltage Protective construction Mounting classication Part No. 1 Form A Micro ISO plug-in type ACV31012 12 V DC Sealed type 1 Form C Micro ISO plug-in type ACV11012 Note: Please use ACV212 to order built-in resistor type. (Asterisks should be lled in from ORDERING INFORMATION.) Standard packing Carton: 50 pcs. Case: 200 pcs. RATING 1. Coil data Nominal operating Nominal operating Nominal coil Pick-up voltage* Drop-out voltage Coil resistance Usable voltage range current power voltage (at 20C 68F) (at 20C 68F) 10% (at 20C 68F) (at 85C 185F) 10% (at 20C 68F) (at 20C 68F) Max. 7.0 V DC Min. 0.6 V DC 67 mA, 180 , 0.8 W, 12V DC 10 to 16V DC (Initial) (Initial) 84 mA (with resistor) 142.3 (with resistor) 1.0 W (with resistor) Note: * Other pick-up voltage types are also available. Please contact us for details. ASCTB230E 201203-T1 Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/CV (ACV) 2. Specications Characteristics Item Specications Arrangement 1 Form A 1 Form C Contact resistance (Initial) Typ 3m (By voltage drop 6V DC 1A) Contact N.O.: Max. 0.2 V (By voltage drop 14 V DC 20 A) Contact voltage drop (after electrical life test) N.O.: Max. 0.2 V (By voltage drop 14 V DC 20 A) N.C.: Max. 0.5 V (By voltage drop 14 V DC 10 A) Contact material Ag alloy (Cadmium free) Nominal switching capacity (resistive load) N.O.: 20 A 14V DC N.O.: 20 A 14V DC, N.C.: 10 A 14V DC Max. carrying current N.O.: 20 A 14V DC N.O.: 20 A 14V DC (at 85C 185F, continuous) N.C.: 10 A 14V DC Rating Nominal operating power 0.8 W, 1.0 W (built-in resistor type) 1 Min. switching capacity (resistive load)* 1 A 12V DC Insulation resistance (Initial) Min. 20 M (at 500V DC) Between open contacts 500 Vrms for 1 min. (Detection current: 10mA) Breakdown voltage (Initial) Between contacts and coil 500 Vrms for 1 min. (Detection current: 10mA) Electrical Operate time (at nominal voltage) characteristics Max. 10ms (excluding contact bounce time) (Initial) (at 20C 68F) Release time (at nominal voltage) Max. 10ms (excluding contact bounce time) (Initial) (at 20C 68F) 2 Functional Min. 100 m/s 10G (Half-wave pulse of sine wave: 11ms detection time: 10s) Shock resistance 2 Destructive Min. 1,000 m/s 100G (Half-wave pulse of sine wave: 6ms) Mechanical 2 characteristics Functional 10 Hz to 100 Hz, Min. 44.1 m/s 4.5G (Detection time: 10s) Vibration resistance 2 Destructive 10 Hz to 500 Hz, Min. 44.1 m/s 4.5G , Time of vibration for each direction X, Y, Z direction: 4 hours 6 Mechanical Min. 10 (at 120 cpm) Expected life 5 Electrical (at nominal switching capacity) Min. 10 (operating frequency: 2s ON, 2s OFF) 3 Ambient temperature: 40C to +85C 40F to +185F* , Conditions for operation, transport and Conditions Humidity: 5% R.H. to 85% R.H. (Not freezing and condensing at low temperature), 2 storage* air pressure: 86 to 106kPa Mass Approx. 15 g .53 oz Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the actual load. *2. The upper operation ambient temperature limit is the maximum temperature that can satisfy the coil temperature rise value. Please refer to Usage ambient condition in CAUTIONS FOR USE OF AUTOMOTIVE RELAYS. *3. Please inquire if you will be using the relay in a high temperature atmosphere. * Regarding solder, this product is not MIL (Military Standard) compliant. Please evaluate solder mounting by the actual equipment before using. REFERENCE DATA 1. Coil temperature rise (20A) 2. Distribution of pick-up and drop-out voltage 3. Distribution of operate and release time Point measured: Inside the coil Sample: ACV11012, 100pcs Sample: ACV11012, 100pcs. Contact carrying current: 20A Coil applied voltage: 13.5V 70 100 180 Operate time Pick-up voltage 90 Drop-out voltage Release time 60 150 80 20A 50 70 120 60 40 90 50 30 40 60 30 20 20 30 10 10 0 0 0 01 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 7.5 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 55 65 75 85 Ambient temperature, C Voltage, V Operate and release time, ms 4. Ambient temperature and operating voltage range 30 25 20 Operation range 15 10 5 Pick-up voltage (Cold start) 0 40 20 0 20 40 60 80 85 100 120 Ambient temperature, C ASCTB230E 201203-T1 Panasonic Corporation Automation Controls Business Unit industrial.panasonic.com/ac/e/ Coil applied voltage, VDC Temperature rise, C Quantity, n Quantity, n