Suitable for lighting and motor load, 1 Form A 50A DJ-H RELAYS (ADJH) latching relays FEATURES TYPICAL APPLICATIONS 15.0 1. High inrush capability 1. Smart house 39.0 .591 1.535 Tungsten load (TV-20 class) (Shutter and Sunblind control) Electronic ballast load (NEMA410) 2. Lighting control 30.2 1.189 Capacitive load (IEC60669-1) 2. Supports manual operation 15.0 39.0 .591 Manual switch type available 1.535 30.2 1.189 Standard type Manual switch type mm inch RoHS compliant Protective construction: Flux-resistant type ORDERING INFORMATION ADJH 2 Contact arrangement 2: 1 Form A Operating function 1: 1 coil latching 2: 1 coil latching (Reverse polarity) 3: 2 coil latching 4: 2 coil latching (Reverse polarity) Type classification 0: Standard type (Without manual switch) 1: Manual switch type Rated voltage (DC) 05: 5V, 12: 12V, 24: 24V TYPES 1. Standard type (Without manual switch) Part No. Standard packing Contact arrangement Rated voltage 1 coil latching type 2 coil latching type Carton Case 5V DC ADJH21005 ADJH23005 1 Form A 12V DC ADJH21012 ADJH23012 50 pcs. 200 pcs. 24V DC ADJH21024 ADJH23024 *Reverse polarity type available. (1 coil latching type: ADJH220**, 2 coil latching type: ADJH240**) ASCTB383E 201704-T 1 NewDJ-H (ADJH2) 2. Manual switch type Part No. Standard packing Contact arrangement Rated voltage 1 coil latching type 2 coil latching type Carton Case 5V DC ADJH21105 ADJH23105 1 Form A 12V DC ADJH21112 ADJH23112 50 pcs. 200 pcs. 24V DC ADJH21124 ADJH23124 *Reverse polarity type available. (1 coil latching type: ADJH221**, 2 coil latching type: ADJH241**) RATING 1. Coil data 1) 1 coil latching type Rated operating current Coil resistance Set voltage Reset voltage Max. allowable voltage 10% (at 20C 68F) 10% (at 20C 68F) Rated voltage Rated operating power 1 1 (at 20C 68F)* (at 20C 68F)* (at 20C 68F) Set coil Reset coil Set coil Reset coil 5V DC 200mA 200mA 25 25 Max. 75% or less of Max. 75% or less of 12V DC rated voltage rated voltage 83.3mA 83.3mA 144 144 1,000mW 130% of rated voltage (Initial) (Initial) 24V DC 41.7mA 41.7mA 576 576 *1. Square, pulse drive 2) 2 coil latching type Rated operating current Coil resistance Set voltage Reset voltage Max. allowable voltage 10% (at 20C 68F) 10% (at 20C 68F) Rated voltage Rated operating power 1 1 (at 20C 68F)* (at 20C 68F)* (at 20C 68F) Set coil Reset coil Set coil Reset coil 5V DC 400mA 400mA 12.5 12.5 Max. 75% or less of Max. 75% or less of 12V DC rated voltage rated voltage 166.7mA 166.7mA 72 72 2,000mW 130% of rated voltage (Initial) (Initial) 24V DC 83.3mA 83.3mA 288 288 *1. Square, pulse drive 2. Specications Characteristics Item Specications Arrangement 1 Form A Contact resistance (initial) Max. 20 m (by voltage drop 24 V DC 1A) Contact material AgSnO2 type Contact rating (resistive) 50A 277V AC Contact data Max. switching power (resistive) 13,850 VA (50A 277V AC) Max. switching voltage 480V AC Max. switching current 50A (AC) 1 Min. switching load (reference value)* 100mA 5 V DC Insulation resistance (initial) Min. 1,000M (at 500V DC) Measured portion is the same as the case of dielectric voltage Between open contacts 1,500 Vrms for 1min. (Detection current: 10mA) Dielectric strength (initial) Between contact and coil 4,000 Vrms for 1min. (Detection current: 10mA) Surge withstand Between contact and coil 12,000 V 2 voltage* (initial) Set time (initial) Max. 20ms (at rated voltage, at 20C 68F, without bounce) Reset time (initial) Max. 20ms (at rated voltage, at 20C 68F, without bounce) 2 Functional 100 m/s (half-sine shock pulse: 11 ms, detection time: 10s) Shock resistance 2 Destructive 1,000 m/s (half-sine shock pulse: 6 ms) Functional 10 to 55 Hz at double amplitude of 1.5 mm (detection time: 10s) Vibration resistance Destructive 10 to 55 Hz at double amplitude of 2.0 mm 6 Expected life Mechanical Min. 110 (at 180 times/min.) Conditions for operation, transport and Ambient Temperature: 40 to +85C 40 to +185F Conditions 3 storage* Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature) Unit weight Approx. 31 g 1.09 oz Notes: *1. Minimum switching load is a guide to the lower current limit of switching under the micro-load. This parameter is changed by the condition, such as switching times, environment condition, and expected reliability. When the relay is used lower than minimum switching load, reliability is attrition. Please use the relay over minimum switching load. *2. Wave is standard shock voltage of 1.250s according to JEC-212-1981 *3. Allowable range when in original packaging is 40 to +70C 40 to +158F. 3. Expected electrical life Type Load Switching capacity Number of operations 4 50A 277V AC Min. 1 10 (ON:OFF = 1s:9s) Resistive 5 25A 277V AC Min. 1 10 (ON:OFF = 1s:9s) 4 1 Form A Tungsten 2,400W 120V AC Min. 2.5 10 (ON:OFF = 1s:59s) Inrush 3 Electronic ballast 20A 277V AC Min. 6 10 (ON:OFF = 1s:9s) load 4 Capacitive (IEC 60669-1) 20A 250V AC 200F Min. 3 10 (ON:OFF = 1s:9s) ASCTB383E 201704-T 2