Pressure Sensor/PSADP4 Pressure Sensor/PFADP1 Pressure Sensor PS/PF series PS Pressure sensor PF Pressure sensor High precision pressure sensor (without amp.) Feature Compact size (PS type) High accuracy and liner characteristic Broad line-up RoHS compliant Typical applications Industrial use Pressure switches and pneumatic components, compressed air pressure measuring devices and airbeds Medical use Blood pressure meters, oxygen generator and airbeds Others Pressure sensing devices for air pressure mediums Ordering information ADP Bridge resistance Terminal profile and direction Rated pressure Code Product name Code Code Type Code 1 PF pressure sensor 1 : DIP terminal 0 4.9 kPa Standard type Nil PF 5 k 1 4 PS pressure sensor 2 34.3 kPa (With glass base) 0 PS 5 k Direction opposite to the pressure inlet direction 3 49.0 kPa Economy type 3 3.3 k 2 4 98.1 kPa (Without glass base) 5 196.1 kPa 6 343.2 kPa 2 : DIP terminal (Pressure inlet direction 7 490.3 kPa 8 833.6 kPa 9 980.7 kPa A 40.0 kPa Types Standard packing : Carton : 100 pcs. Case : 1,000 pcs. Part No. Brige PS pressure sensor PF pressure sensor resistance 5 k 3.3 k 5 k 3.3 k DIP terminal: DIP terminal: DIP terminal: DIP terminal: Terminal DIP terminal: DIP terminal: DIP terminal: DIP terminal: Direction opposite Direction opposite Direction opposite Direction opposite Pressure inlet SMD terminal Pressure inlet Pressure inlet Pressure inlet to the pressure to the pressure to the pressure to the pressure direction direction direction Pressure direction inlet direction inlet direction inlet direction inlet direction Standard type (with glass base) 4.9 kPa ADP41010 ADP42010 ADP1101 ADP1201 34.3 kPa ADP41210 ADP42210 ADP1121 ADP1221 49.0 kPa ADP41310 ADP42310 ADP1131 ADP1231 98.1 kPa ADP41410 ADP42410 ADP4932 ADP41413 ADP42413 ADP1141 ADP1241 196.1 kPa ADP41510 ADP42510 ADP1151 ADP1251 343.2 kPa ADP41610 ADP42610 ADP1161 ADP1261 490.3 kPa ADP41710 ADP42710 ADP1171 ADP1271 833.6 kPa ADP41810 ADP42810 ADP1181 ADP1281 980.7 kPa ADP41910 ADP42910 ADP4933 ADP41913 ADP42913 ADP1191 ADP1291 Economy type (without glass base) 40.0 kPa ADP41A23 ADP42A23 ADP11A23 ADP12A23 Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. 31-Mar-20 PressurePressure Sensor/PS(ADP4), PF(ADP1) Rating Economy type Type Standard type (With glass base) (Without glass base) Type of pressure Gauge pressure *1 Pressure medium Air *2 *2 Rated pressure (kPa) 4.9 34.3 to 343.2 490.3 833.6 980.7 40.0 98.1 980.7 1.5 times of the Twice of the 1.5 times of the Twice of the Max. applied pressure Twice of the rated pressure rated pressure rated pressure rated pressure rated pressure Bridge resistance 5,000 1,000 3,300 700 3,300 600 5 to +50 Ambient temperature 20 to +100 4 to +212 (no freezing or condensation) 23 to +122 20 to +70 Storage temperature 40 to +120 40 to +248 (no freezing or condensation) 4 to +158 Standard temperature 25 77 30 86 25 77 0 to 60 5 to 45 Temperature 0 to 50 32 to +122 compensation range 32 to +140 41 to +113 Drive current 1.5 mA 1.0 mA 1.5 mA (constant current) Output span voltage 40 20 mV 100 40 mV 65 25 mV 43.5 22.5 mV Offset voltage 20 mV 15 mV Linearity 0.7 %FS 0.3 %FS 0.5 %FS 0.6 %FS 1.0 %FS 0.3 %FS Pressure hysteresis 0.6 %FS 0.2 %FS 0.4 %FS 1.0 %FS 0.7 %FS Offset voltage-temperature 15 %FS 5.0 %FS 3.5 %FS 10 %FS *3 characteristics Sensitivity- 10 %FS 2.5 %FS 1.3 %FS temperature *1: Please consult us if a pressure medium other than air is to be used. *2: For PS pressure sensor only *3: This is the regulation which applies within the compensation temperature range. Unless otherwise specified, measurements were taken with a drive current of 0.01 mA and humidity ranging from 25% to 85%. Please consult us if the intended use involves a negative pressure. Reference data PS pressure sensor Characteristics data 1.-(1) Output characteristics 1.-(2) Offset voltage - temperature 1.-(3) Sensitivity -temperature characteristics characteristics AD41913 AD41913 AD41913 Drive current:1.0 mA Drive current:1.0 mARating:3.5 %FS Drive current:1.0 mARating:2.5 %FS Temperature : 30 86 60 4 4 50 3 3 40 2 2 30 1 1 20 0 0 10 -1 -1 0 -2 -2 0 0 0 980.7/2 5 980.7 10 30 86 60 140 30 86 60 140 Puressure (kPa kgf/cm2 ) Temperature ( ) Temperature ( ) Pressure cycle range (0 to rated pressure) 6 Tested sample : ADP41913, temperature : 100 212 , No. of cycle: 110 Offset voltage range Output span voltage range 3 3 Even after testing for 1 million times, 2 2 the variations in the offset voltage 1 1 and output span voltage 0 0 are minimal. -1 -1 -2 -2 -3 -3 6 6 6 6 0 510 110 0 510 110 Pressure cycle(Cycle) Pressure cycle(Cycle) Design and specifications are each subject to change without notice. Ask factory for the current technical specifications before purchase and/or use. Should a safety concern arise regarding this product, please be sure to contact us immediately. 31-Mar-20 Output voltage (mV) Offset voltage range (%FS) Offset voltage-temperature Output span voltage range (%FS) characteristics (%FS) Sensitivity-temperature characteristics (%FS)