1 Form A 60A
DQ-M RELAYS (ADQM)
power latching relays
FEATURES
1. Miniature and high capacity 3. High insulation
Miniature relay capable of high 60 A Between contact and coil
capacity control. Breakdown voltage: 4,000 V AC
Size: 29.0(L)38.0(W)17.3(H) mm Surge breakdown voltage: 10,000 V
1.142(L)1.496(W).681(H) inch
Nominal switching capacity:
TYPICAL APPLICATIONS
60A 250V AC
2. Latching type 1. Remote control of electric power
Latching type contributes to device meters
RoHS compliant
energy efciency. 2. Time switches
Nominal operating power
Protective construction: Flux-resistant 500mW (1 coil latching)
type 1,000mW (2 coil latching)
ORDERING INFORMATION
ADQM 6 0
DQ-M relays
Operating function
1: 1 coil latching (1 Form A)
2: 2 coil latching (1 Form A)
Contact capacity
6: 60 A
Terminal shape
Nil: M4 securing screw
Contact material
0: Standard contact (AgNi type)
Nominal coil voltage (DC)
4H: 4.5 V, 06: 6 V, 09: 9 V, 12: 12 V, 24: 24 V
TYPES
Part No.
Contact Nominal coil
arrangement voltage
1 coil latching 2 coil latching
4.5V DC ADQM1604H ADQM2604H
6V DC ADQM16006 ADQM26006
1 Form A 9V DC ADQM16009 ADQM26009
12V DC ADQM16012 ADQM26012
24V DC ADQM16024 ADQM26024
Standard packing: Carton: 20 pcs.; Case: 200 pcs.
ASCTB179E 201607-T
1DQ-M (ADQM)
RATING
1. Coil data
1) 1 coil latching
Nominal operating
Nominal coil Set voltage Reset voltage Coil resistance Nominal operating Max. applied voltage
current
voltage (at 20C 68F) (at 20C 68F) [10%] (at 20C 68F) power (at 20C 68F)
[10%] (at 20C 68F)
4.5V DC 111.1mA 40.5
6V DC 83.3mA 72
80%V or less of 80%V or less of
130%V of
9V DC nominal voltage nominal voltage 55.6mA 162 500mW
nominal voltage
(Initial) (Initial)
12V DC 41.7mA 288
24V DC 20.8mA 1,152
2) 2 coil latching
Nominal operating
Nominal coil Set voltage Reset voltage Coil resistance Nominal operating Max. applied voltage
current
voltage (at 20C 68F) (at 20C 68F) [10%] (at 20C 68F) power (at 20C 68F)
[10%] (at 20C 68F)
4.5V DC 221.7mA 20.3
6V DC 166.7mA 36
80%V or less of 80%V or less of
130%V of
9V DC nominal voltage nominal voltage 111.1mA 81 1,000mW
nominal voltage
(Initial) (Initial)
12V DC 83.3mA 144
24V DC 41.7mA 576
2. Specications
Characteristics Item Specications
Arrangement 1 Form A
Contact Contact resistance (Initial) Max. 30 m (By voltage drop 6 V DC 1A)
Contact material AgNi type
Nominal switching capacity (resistive load) 60 A 250V AC
Max. switching power (resistive load) 15,000 V A
Max. switching voltage 250V AC
Rating
Max. switching current 60 A AC
Nominal operating power 500mW (1 coil latching), 1,000mW (2 coil latching)
1
Min. switching capacity (Reference value)* 100mA 5 V DC
Insulation resistance (Initial) Min. 1,000M (at 500V DC) Measurement at same location as Breakdown voltage section.
Between open contacts 1,500 Vrms for 1min. (Detection current: 10mA.)
Breakdown voltage
(Initial)
Between contact and coil 4,000 Vrms for 1min. (Detection current: 10mA.)
Electrical
Surge breakdown
characteristics
Between contact and coil Min. 10,000 V
2
voltage* (Initial)
Set time (at 20C 68F) (Initial) Max. 20 ms (Nominal voltage applied to the coil, excluding contact bounce time.)
Reset time (at 20C 68F) (Initial) Max. 20 ms (Nominal voltage applied to the coil, excluding contact bounce time.)
2
Functional Min. 200 m/s (Half-wave pulse of sine wave: 11 ms; detection time: 10s.)
Shock resistance
2
Destructive Min. 1,000 m/s (Half-wave pulse of sine wave: 6 ms.)
Mechanical
characteristics
Functional 10 to 55 Hz at double amplitude of 1.5 mm (Detection time: 10s.)
Vibration resistance
Destructive 10 to 55 Hz at double amplitude of 2.0 mm
6
Mechanical Min. 10 (at 180 times/min.)
3
Expected life 60A 250V AC Min. 10 (resistive load, operating frequency: 15s ON, 45s OFF)
Electrical
4
50A 250V AC Min. 10 (resistive load, operating frequency: 15s ON, 45s OFF)
Ambient temperature: 40 to +70C 40 to +158F
3
Conditions for operation, transport and storage*
Humidity: 5 to 75% R.H. (Not freezing and condensing at low temperature)
Conditions
Max. operating speed 1 times/min. (at rated load)
Unit weight Approx. 35 g 1.23 oz