Automation Controls Catalog
IEC62055-31 UC3 compliant
(short current 3,000 A)
DZ RELAYS (ADZ)
1 Form A 120A power
latching relays
FEATURES TYPICAL APPLICATIONS
1. IEC62055-31 UC3 compliant (short 1. Smart meters
current 3,000 A) 2. Charge station
2. High switching capacity 3. Other industrial equipment
120 A 250 VAC (Resistive load)
3. Twin contacts for low temperature
rise
Horizontal terminal type
4. Low operating power
1 coil latching: 1.4 W
2 coil latching: 2.8 W
5. Small size: W: 41 x L: 35 x H: 22 mm
W: 1.614 x L: 1.378 x H: .866 inch
Vertical terminal type
RoHS compliant
Protective construction: Dust cover type
ORDERING INFORMATION
ADZ 2 1
Operating function
1: 1 coil latching
2: 2 coil latching
Contact capacity
2: 120 A
Contact material
1: AgSnO2 type
Nominal coil voltage (DC)
05: 5 V, 12: 12 V, 24: 24 V
Terminal shape
H: Horizontal type
V: Vertical type
TYPES
Part No.
Contact Nominal coil
1 coil latching 2 coil latching
arrangement voltage
Horizontal terminal type Vertical terminal type Horizontal terminal type Vertical terminal type
5 V DC ADZ12105H ADZ12105V ADZ22105H ADZ22105V
1 Form A 12 V DC ADZ12112H ADZ12112V ADZ22112H ADZ22112V
24 V DC ADZ12124H ADZ12124V ADZ22124H ADZ22124V
Standard packing: Carton: 20 pcs.; Case: 100 pcs.
industrial.panasonic.com/ac/e/ Panasonic Corporation 2014 ASCTB338E 201402-T
2014.02
1
New
NewDZ (ADZ)
RATING
1. Coil data
1) 1 coil latching
Nominal operating
Nominal coil Set voltage Reset voltage Coil resistance Nominal operating Max. applied voltage
current
voltage (at 20C 68F) (at 20C 68F) [10%] (at 20C 68F) power (at 20C 68F)
[10%] (at 20C 68F)
5 V DC 280.0 mA 17.9
*70%V or less of *70%V or less of
130%V of
12 V DC nominal voltage nominal voltage 116.7 mA 102.9 1,400 mW
nominal voltage
(Initial) (Initial)
24 V DC 58.3 mA 411.4
2) 2 coil latching
Nominal operating
Nominal coil Set voltage Reset voltage Coil resistance Nominal operating Max. applied voltage
current
voltage (at 20C 68F) (at 20C 68F) [10%] (at 20C 68F) power (at 20C 68F)
[10%] (at 20C 68F)
5 V DC 560.0 mA 8.9
*70%V or less of *70%V or less of
130%V of
12 V DC nominal voltage nominal voltage 233.3 mA 51.4 2,800 mW
nominal voltage
(Initial) (Initial)
24 V DC 116.7 mA 205.7
*Pulse drive (JIS C 5442-1996)
2. Specications
Specications
Characteristics Item
1 coil latching 2 coil latching
Arrangement 1 Form A
Contact Contact voltage drop Max. 0.12V (at 120A), Max. 0.10V (at 20A)
Contact material AgSnO2 type
Nominal switching capacity (resistive load) 120 A 250 V AC
Max. switching power (resistive load) 30,000 VA
Max. switching voltage 276 V AC
Rating
Max. switching current 120 A AC
Nominal operating power 1,400 mW (1 coil latching) 2,800 mW (2 coil latching)
1
Min. switching capacity (Reference value)* 100 mA 24 V DC
Insulation resistance (Initial) Min. 1,000 M (at 500 V DC) Measurement at same location as Breakdown voltage section.
Between open contacts 2,000 Vrms for 1min. (Detection current: 10 mA)
Breakdown voltage
(Initial)
Between contact and coil 4,000 Vrms for 1min. (Detection current: 10 mA)
Electrical
4
Overcurrent resistance (Initial) Min. 3,000 A (Half-wave pulse of sine wave: 10 ms)*
characteristics
2
Surge breakdown voltage* (Between contact and coil) 12,000 V (Initial)
Set time (at 20C 68F) Max. 20 ms (Nominal voltage applied to the coil, excluding contact bounce time)
Reset time (at 20C 68F) Max. 20 ms (Nominal voltage applied to the coil, excluding contact bounce time)
2
Functional 300 m/s (Half-wave pulse of sine wave: 11 ms; detection time: 10 s)
Shock resistance
2
Destructive 1,000 m/s (Half-wave pulse of sine wave: 6 ms)
Mechanical
characteristics
Functional 10 to 55 Hz at double amplitude of 1.5 mm (Detection time: 10 s)
Vibration resistance
Destructive 10 to 55 Hz at double amplitude of 2.0 mm
5
Mechanical Min. 10 (at 180 times/min.)
3
Resistive load 120 A 250 V AC Min. 10 (operating frequency: ON : OFF = 10 s : 20 s)
3
Expected life*
4
Electrical
100 A 276 V AC Min. 10
UC3 class
5
(cos = 1.0 : 5,000, cos = 0.5 : 5,000, operating frequency: ON : OFF = 10 s : 20 s)*
Ambient temperature: 40C to +85C 40F to +185F
3
Conditions Conditions for operation, transport and storage*
Humidity: 5 to 85% R.H. (Not freezing and condensing at low temperature)
Unit weight Approx. 75 g 2.65 oz
Notes: *1. This value can change due to the switching frequency, environmental conditions, and desired reliability level, therefore it is recommended to check this with the
actual load.
*2. Wave is standard shock voltage of 1.2 50 s according to JEC-212-1981
*3. The upper limit of the ambient temperature is the maximum temperature that can satisfy the coil temperature rise value. Refer to Usage, operation, transport and
storage conditions in NOTES.
*4. IEC62055-31 UC3 compliant
*5. Based on IEC62055-31 UC3, inductive load test was conducted after resistive load test, and expressed as total.
Panasonic Corporation Automation Controls Business Division
Panasonic Corporation 2014 ASCTB338E 201402-T
industrial.panasonic.com/ac/e/
2