Dimensions (unit: mm in) FP0R/FP FP-X Typical Part No.: AFP0RC32T Typical Part No.: AFPX-C30 ** <Reference measuring for wiring> (18) Programmable Controller 100 3.5 60.0 30.0 60.0 (0.71) Input 2.36 1.18 2.36 3.94 0.14 connector 100 240V~ COM X1 X3 X5 X7 X9 XB XD XF L N FPSERIES DIGEST COM X0 X2 X4 X6 X8 XA XC XE RUN PROG. ERR. 0 7 X 8 F 0 7 Y 8 D 90.0 Panasonic * FP-X C30 3.54 90 90.0 RUN 3.54 3.54 min. max. V0 130.0 5.12 approx. V1 0V Y0 Y1 Y2 Y4 C3 Y7 Y9 YA YC (4.5) 24V C0 C1 C2 Y3 Y5 Y6 Y8 C4 YB YD (9) (0.18) (7.5) Output connector (0.35) (0.3) RS232C port (10) DIN standard rail (Only the equipped model) (0.39) (DIN EN50022 35 mm 1.38 in width) RS485 port 13.0 0.51 (Only the equipped model) * DIN rail is attached on the center of the unit. FP2SH DIN standard rail attachment groove 0.5 0.02 L2 (DIN EN50022 35 mm 1.38 in width) L1 0.5 90 100 0.02 3.54 3.94 4-M4 M0.16 FP-e Mounting dimension (Tolerance: 1.0 0.04) FP0R Conventional backplanes (15.3) FP-X (0.60) 5-module 7-module 9-module 12-module 14-module FP L1 (mm in) 140 5.51 209 8.23 265 10.43 349 13.74 405 15.95 L2 (mm in) 130 5.12 199 7.84 255 10.04 339 13.35 395 15.55 FP2 93 3.66 Note: The 5-module type does not have an expansion connector. 120 FP2SH H type backplanes 11-module (master backplane) 10-module (expansion backplane) Note: The illustration shows a conventional 7-module type backplane. L1 (mm in) 349 13.74 349 13.74 L2 (mm in) 339 13.35 339 13.35 Please contact: 2431-1 Ushiyama-cho, Kasugai-shi, Aichi, 486-0901, Japan Global Sales Department Telephone: +81-568-33-7861 Facsimile: +81-568-33-8591 panasonic.net/id/pidsx/global All Rights Reserved 2016 No. CE-FPDJS-1-5 February, 2016 Specifications are subject to change without notice. Printed in Japan panasonic.net/id/pidsx/global 2016.02Programmable Controller FP Series Selection of Products Model Features FP-e FP0R FP FP-X FP2SH PLC + Display + Switch Controller superior to basic High performance ultra-compact High performance compact Scan time: 1 ms/20 k steps All-in-one controller with ultra-compact models controller terminal block type controller Advanced version of FP2 six functions Ideal for use in extremely Reliably supports the control of Wide selection of add-on cassettes capable of ultra-high speed narrow spaces higher-speed equipment with allows space-saving use of the processing more functions featured controller for a variety of purposes *The FP-e will be discontinued at the end of September, 2019. With thermocouple C2P C3P CPU (control unit) type Basic type C10, C14 and C16 C32 T32 F32 C24 C28 C32 C14 C30 C60 C2L C2 input type (with IC memory card interface) (with IC memory card interface) Maximum controllable I/O points 14 points 12 points 106 to 112 points 128 points 128 points 128 points 376 points 380 points 384 points 328 points 352 points 382 points 2,048 points (8,192 points with the remote I/O system) 3 units Connectable expansion units 7 units (Right: 3, Left: 4) 8 units + Add-on cassettes (up to 3) 32 units (When the H type backplane is used) 32 k steps 60 k steps 120 k steps Program capacity 2.7 k steps 16 k steps 32 k steps 32 k steps 16 k steps 32 k steps Comment memory Available (Built-in memory) Available (Built-in memory) Available (Built-in memory) Available (Built-in memory) Operation speed (basic instructions) 0.9 s/step (basic instructions) 0.08 s (Up to 3 k steps), 0.58 s (3 k and later steps) 0.32 s/step (basic instructions) 0.32 s/step (basic instructions) 0.03 s/step (basic instructions) Data register 1,660 words 12,315 words 32,756 words 32,765 words 32,765 words 10,240 words (Exc. file register. See the end of this table.) 1,008 points (63 words) 4,096 points (256 words) Internal relay 4,096 points (256 words) 4,096 points (256 words) 14,192 points Available (with FP Web Server 2 and KS1 Signal converter) Network Ethernet Available (Ethernet communication cassette) Available (ET-LAN unit) compatibility FL-NET Available (VE link unit) Modbus-RTU Available (RS485 type) Available (RS485) Available (RS485 communication cassette) Available (RS485 communication cassette) CC-Link Available (Slave, CC-Link unit) Available (Slave, CC-Link unit) Available (Slave and FP0 CC-Link unit) Computer link Available (Tool port, COM port) Available (Tool port, COM port) Available (Tool port, communication cassette) Available (Tool port and communication cassette) Available (COM port, CCU and MCU) (MEWTOCOL) General-purpose serial Available (COM port) Available (COM port) Available (Tool port, communication cassette) Available (Tool port and communication cassette) Available (COM port, SDU and MCU) (nonprocedural) PLC link W Available (MW link unit) W0 Available (RS232C, 1-to-1) (RS485, Up to 16 units) Available(MCU) Available (RS485 communication cassette) Available (RS485 communication cassette) W2 Available (MW link unit) VE Available (VE link unit) Remote I/O Available (Master: MW link unit) Available (64-point slave stations, I/O link unit) Available (64-point slave stations, I/O link unit) Available (64-point slave stations and FP0 I/O link unit) (MEWNET-F) (Slave: RMS unit) Available (FP0-SL1 control unit) S-LINK Available (S-LINK unit) Available (S-LINK unit) S-LINK V Available (S-LINK V unit) Motor Built-in pulse output 2 axes/10 kHz 2 axes/5 kHz 4 axes/50 kHz (C16, C32 or T32) 2 axes/100 kHz (Transistor output type) 2 axes/100 kHz + 2 axes/20 kHz (Transistor output type) control Positioning unit 2-axis/4-axis type, up to 16 axes 1 axis/100 kHz (pulse I/O add-on cassette) RTEX, Multifunction type and Interpolation type PWM output 2 points/1 kHz/1,000 resolution 4 points/4.8 kHz/1,000 resolution (C16, C32, T32 or F32) 2 points/12 kHz/1,000 resolution (Transistor output type) 4 points/12 kHz/1,000 resolution (Transistor output type) 4 points/30 kHz/100 resolution (Pulse I/O unit) High-speed counter 6 channels/50 kHz 4 channels/50 kHz 8 channels/50 kHz 4 points/200 kHz (FP2-HSCT and FP2-PXYT) 4 channels/10 kHz 4 channels/5 kHz 2 channels input and 1 channel 2 channels input and 1 channel Analog Voltage/current input 4 channels/unit, 8 channels/unit 4 channels/unit, 8 channels/unit 2 channels/cassette 8 channels (FP2-AD8VI and FP2-AD8X) 2 channels input and 1 channel output/4 channels input and output/4 channels input and measurement output mixed cassette 4 channels/unit 4 channels/unit 2 channels/cassette Voltage/current output 2 channels output mixed unit 2 channels output mixed unit 4 channels (FP2-DA4) Temperature input 2 channels (thermocouple) 8 channels thermocouple unit 8 channels thermocouple unit 2 channels thermocouple input and 2 channels R.T.D. input cassettes 8 channels thermocouple/R.T.D. (FP2-AD8X and FP2-RTD) Calendar timer (clock function) Available (With calendar timer type) Available (T32 only) Available Available (MRTC cassette) Available (Built-in type) File register (60 k steps / 120 k steps: 32,765 words x 3 banks) Others Front panel switch input: 8 points MiniUSB port provided Potentiometer input: 2 points With a USB port (C30 and C60) (32 k steps: 32,765 words) 2 3